Characterization of the BOLDPET optical prototype, an innovative Cherenkov detector for 511 keV $γ$ radiation
Authors:
Roman Chyzh,
Gerard Tauzin,
Dominique Yvon,
Chi-Hsun Sung,
Dominique Breton,
Jihane Maalmi,
Klaus Schäfers,
Christian Weinheimer,
Viatcheslav Sharyy
Abstract:
In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET technology uses an innovative detection liquid, trimethylbismuth, for detecting 511 keV $γ$-quanta resulting from positron annihilation. The optical signal is exclus…
▽ More
In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET technology uses an innovative detection liquid, trimethylbismuth, for detecting 511 keV $γ$-quanta resulting from positron annihilation. The optical signal is exclusively produced through the Cherenkov mechanism, and the produced photons are detected using Planacon microchannel-plate photomultiplier. We achieve an excellent time resolution of 150 ps (FWHM) within a sizable detection volume measuring 55 mm x 55 mm x 25 mm. Through detailed Geant4 simulations, we examine the limiting factors affecting time resolution and explore potential avenues for improvement. Furthermore, we demonstrate the feasibility of coarse 2D localization of interactions using the optical signal alone, achieving a precision of about 5-8 mm (FWHM) within the homogeneous detection volume.
△ Less
Submitted 2 July, 2024; v1 submitted 30 January, 2024;
originally announced January 2024.
-
Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence
Authors:
Chi-Hsun Sung,
Laurie Cappellugola,
Megane Follin,
Sébastien Curtoni,
Mathieu Dupont,
Christian Morel,
Aline Galindo-Tellez,
Roman Chyzh,
Dominique Breton,
Jihane Maalmi,
Dominique Yvon,
Viatcheslav Sharyy
Abstract:
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result t…
▽ More
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result together from the 511 keV gamma-ray interation into the PWO crystal. A micro-channel plate photomultiplier tube (MCP-PMT) encapsulating the PWO crystal amplifies photoelectrons generated at the photocathode, and the corresponding anode signals are collected through the transmission lines read out at both ends and digitized by a SAMPIC module. In this work, we present a realistic Geant4 simulation of the ClearMind prototype detector, including the propagation of the visible photons in the crystal, the modelling of a realistic response of the photocathode and of the PMT, and the propagation of the electrical signals over the transmission lines. The reconstruction of the gamma conversion in the detector volume is performed from the signals registered at both ends of the transmission lines. We compare the reconstruction precision of a statistical algorithm against machine learning algorithms developed using the TMVA package. We expect to reach a spatial resolution down to a few mm$^3$ (FWHM). Finally, we will discuss prospects for the ClearMind detector.
△ Less
Submitted 26 January, 2023; v1 submitted 23 September, 2022;
originally announced September 2022.
-
High resolution MCP-PMT Readout Using Transmission Lines
Authors:
M. Follin,
R. Chyzh,
C. -H. Sung,
D. Breton,
J. Maalmi,
T. Chaminade,
E. Delagnes,
K. Schäfers,
C. Weinheimer,
D. Yvon,
V. Sharyy
Abstract:
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection modul…
▽ More
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection module for the positron emission tomography using the liquid detection media, the tri-methyl bismuth. In this study we use the commercial MCP-PMT Planacon from Photonis, with 32x32 anode structure. The PCB gathers signals from anode pads in 32 transmission lines which are read-out from both ends. Amplifier boards and SAMPIC modules, developed in our labs, allow us to realize the cost-effective, multi-channel digitization of signals with excellent precision. For a single photo-electron, we measured a time resolution of 70~ps (FWHM) simultaneously with a spatial accuracy of 1.6~mm and 0.9~mm (FWHM) along and across transmission lines correspondingly.
△ Less
Submitted 25 November, 2021; v1 submitted 7 August, 2021;
originally announced August 2021.