-
Design,fabrication and characterization of 8x9 n-type silicon pad array for sampling calorimetry
Authors:
Sawan,
G. Tambave,
J. L. Bouly,
O. Bourrion,
T. Chujo,
A. Das,
M. Inaba,
V. K. S. Kashyap,
C. Krug,
R. Laha,
C. Loizides,
B. Mohanty,
M. M. Mondal N. Ponchant,
K. P. Sharma,
R. Singh,
D. Tourres
Abstract:
This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out…
▽ More
This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out using the High Granularity Calorimeter Readout Chip~(HGCROC). This paper covers the Technology Computer-Aided Design (TCAD) simulations, the fabrication process, current versus voltage (IV) and capacitance versus voltage (CV) measurements, test results with a blue LED and $^{90}$Sr beta source, and neutron radiation hardness tests. IV measurements for the detector showed that 90\% of the pads had leakage current below 10~nA at full depletion voltage. Simulations predicted a breakdown voltage of 1000~V and practical tests confirmed stable operation up to 500~V without breakdown. CV measurements in the data and the simulations gave a full depletion voltage of around 50~V at a capacitance of 35~pF. LED tests verified that all detector pads responded correctly. Additionally, the 1$\times$1 cm$^2$ pads were also tested with the neutron radiations at a fluence of $5\times10^{13}$ 1~MeV~n$_{eq}$/cm$^2$.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
Beam test of n-type Silicon pad array detector at PS CERN
Authors:
Sawan,
M. Bregant,
J. L. Bouly,
O. Bourrion,
A. van den Brink,
T. Chujo,
C. Krug,
L. Kumar,
V. K. S. Kashyap,
A. Ghimouz,
M. Inaba,
T. Isidori,
C. Loizides,
B. Mohanty,
M. M. Mondal,
N. Minafra,
N. Novitzky,
N. Ponchant,
M. Rauch,
K. P. Sharma,
R. Singh,
D. Thienpont,
D. Tourres,
G. Tambave
Abstract:
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored…
▽ More
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace μ}$m thick, and high-resistivity ($\sim$7 k$Ω\thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.
△ Less
Submitted 20 March, 2024;
originally announced March 2024.
-
Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter
Authors:
M. Aehle,
J. Alme,
C. Arata,
I. Arsene,
I. Bearden,
T. Bodova,
V. Borshchov,
O. Bourrion,
M. Bregant,
A. van den Brink,
V. Buchakchiev,
A. Buhl,
T. Chujo,
L. Dufke,
V. Eikeland,
M. Fasel,
N. Gauger,
A. Gautam,
A. Ghimouz,
Y. Goto,
R. Guernane,
T. Hachiya,
H. Hassan,
L. He,
H. Helstrup
, et al. (50 additional authors not shown)
Abstract:
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS a…
▽ More
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
A Large-Scale Pad-Sensor Based Prototype of the Silicon Tungsten Electromagnetic Calorimeter for the Forward Direction in ALICE at LHC
Authors:
R. G. E. Barthel,
T. Chujo,
T. Hachiya,
M. Hatakeyama,
Y. Hoshi,
M. Inaba,
Y.,
Kawamura,
D. Kawana,
C. Loizides,
Y. Miake,
Y. Minato,
K. Nakagawa,
N. Novitzky,
T. Peitzmann,
M. Rossewij,
M. Shimomura,
T. Sugitate,
T. Suzuki,
K. Tadokoro,
M. Takamura,
S. Takasu,
A. van den Brink,
M. van Leeuwen
Abstract:
We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'', consists of 20 layers of silicon pad sensors and tungsten alloy plates with printed circuit boards and readout electronics. The constructed detector was tested at the…
▽ More
We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'', consists of 20 layers of silicon pad sensors and tungsten alloy plates with printed circuit boards and readout electronics. The constructed detector was tested at the test beam facility of the Super Proton Synchrotron (SPS) at CERN. We obtain an energy resolution of about 4.3% for electron beams at both 150 and 250 GeV/$c$, which is consistent with realistic detector response simulations. Longitudinal profiles of electromagnetic shower were also measured and found to agree with the simulations. The same prototype detector was installed in the ALICE experimental area about 7.5m away from the interaction point. It was used to measure inclusive electromagnetic cluster energy distributions and neutral-pion candidate invariant mass distributions for pseudo-rapidity of $η$=3.7-4.5 in proton-proton collisions at $\sqrt{s}$ = 13 TeV at LHC. The measured distributions in different $η$ regions are similar to those obtained from PYTHIA simulations.
△ Less
Submitted 18 March, 2024; v1 submitted 9 June, 2023;
originally announced June 2023.
-
Design of the ECCE Detector for the Electron Ion Collider
Authors:
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin,
R. Capobianco
, et al. (259 additional authors not shown)
Abstract:
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent track…
▽ More
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. This detector concept has been selected to be the basis for the EIC project detector.
△ Less
Submitted 11 May, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Detector Requirements and Simulation Results for the EIC Exclusive, Diffractive and Tagging Physics Program using the ECCE Detector Concept
Authors:
A. Bylinkin,
C. T. Dean,
S. Fegan,
D. Gangadharan,
K. Gates,
S. J. D. Kay,
I. Korover,
W. B. Li,
X. Li,
R. Montgomery,
D. Nguyen,
G. Penman,
J. R. Pybus,
N. Santiesteban,
R. Trotta,
A. Usman,
M. D. Baker,
J. Frantz,
D. I. Glazier,
D. W. Higinbotham,
T. Horn,
J. Huang,
G. Huber,
R. Reed,
J. Roche
, et al. (258 additional authors not shown)
Abstract:
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fr…
▽ More
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirmed the proposed technology and design satisfy the requirements. The projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb^-1 of integrated luminosity. Additionally, a few insights on the potential 2nd Interaction Region can (IR) were also documented which could serve as a guidepost for the future development of a second EIC detector.
△ Less
Submitted 6 March, 2023; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will…
▽ More
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will be presented. The ECCE detector has enabled precise EIC heavy flavor hadron and jet measurements with a broad kinematic coverage. These proposed heavy flavor measurements will help systematically study the hadronization process in vacuum and nuclear medium especially in the underexplored kinematic region.
△ Less
Submitted 23 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Exclusive J/$ψ$ Detection and Physics with ECCE
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the…
▽ More
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the spatial distribution of gluons in the nucleus. Recently the problem of the origin of hadron mass has received lots of attention in determining the anomaly contribution $M_{a}$. The trace anomaly is sensitive to the gluon condensate, and exclusive production of quarkonia such as J/$ψ$ and $Υ$ can serve as a sensitive probe to constrain it. In this paper, we present the performance of the ECCE detector for exclusive J/$ψ$ detection and the capability of this process to investigate the above physics opportunities with ECCE.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
Authors:
F. Bock,
N. Schmidt,
P. K. Wang,
N. Santiesteban,
T. Horn,
J. Huang,
J. Lajoie,
C. Munoz Camacho,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (263 additional authors not shown)
Abstract:
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key…
▽ More
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
AI-assisted Optimization of the ECCE Tracking System at the Electron Ion Collider
Authors:
C. Fanelli,
Z. Papandreou,
K. Suresh,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann
, et al. (258 additional authors not shown)
Abstract:
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to…
▽ More
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.
△ Less
Submitted 19 May, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Scientific Computing Plan for the ECCE Detector at the Electron Ion Collider
Authors:
J. C. Bernauer,
C. T. Dean,
C. Fanelli,
J. Huang,
K. Kauder,
D. Lawrence,
J. D. Osborn,
C. Paus,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (256 additional authors not shown)
Abstract:
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing thes…
▽ More
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. In this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.
△ Less
Submitted 17 May, 2022;
originally announced May 2022.
-
Design and Performance of a Silicon Tungsten Calorimeter Prototype Module and the Associated Readout
Authors:
T. Awes,
C. L. Britton,
T. Chujo,
T. Cormier,
M. N. Ericson,
N. B. Ezell,
D. Fehlker,
S. S. Frank,
Y. Fukuda,
T. Gunji,
T. Hachiya,
H. Hamagaki,
S. Hayashi,
M. Hirano,
R. Hosokawa,
M. Inaba,
K. Ito,
Y. Kawamura,
D. Kawana,
B. Kim,
S. Kudo,
C. Loizides,
Y. Miake,
G. Nooren,
N. Novitzky
, et al. (19 additional authors not shown)
Abstract:
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance o…
▽ More
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.
△ Less
Submitted 9 December, 2020; v1 submitted 23 December, 2019;
originally announced December 2019.
-
Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter
Authors:
Sanjib Muhuri,
Sourav Mukhopadhyay,
Vinay B. Chandratre,
Tapan K. Nayak,
Sumit Kumar Saha,
Sanchari Thakur,
Rama N. Singaraju,
Jogender Saini,
Anthony van den Brink,
Tatsuya Chujo,
Rajendra Nath Patra,
Marco van Leeuwen,
Shuaib Ahmad Khan,
Menka Sukhwani,
Gert-Jan Nooren,
Thomas Peitzmann
Abstract:
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of electromagnetic showers over a large energy range. The signal from each of the silicon pads is readout using an ASIC with a dynamic range from $-300$~fC to $+500$~f…
▽ More
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of electromagnetic showers over a large energy range. The signal from each of the silicon pads is readout using an ASIC with a dynamic range from $-300$~fC to $+500$~fC. Another ASIC with a larger dynamic range, $\pm 600$~fC has been used as a test study. The calorimeter was exposed to pion and electron beams at the CERN Super Proton Synchrotron (SPS) to characterise the response to minimum ionising particles (MIP) and showers from electromagnetic (EM) interactions. Pion beams of 120 GeV provided baseline measurements towards the understanding of the MIP behaviour in the silicon pad layers, while electron beams of energy from 5 GeV to 60 GeV rendered detailed shower profiles within the calorimeter. The energy deposition in each layer, the longitudinal shower profile, and the total energy deposition have been measured for each incident electron energy. Linear behaviour of the total measured energy ($E$) with that of the incident particle energy ($E_{0}$) ensured satisfactory calorimetric performance. For a subset of the data sample, selected based on the cluster position of the electromagnetic shower of the incident electron, the dependence of the measured energy resolution on $E_{0}$ has been found to be $σ/E = (15.36/\sqrt{E_0(\mathrm{GeV)}} \oplus 2.0) \%$.
△ Less
Submitted 13 January, 2020; v1 submitted 2 November, 2019;
originally announced November 2019.
-
A next-generation LHC heavy-ion experiment
Authors:
D. Adamová,
G. Aglieri Rinella,
M. Agnello,
Z. Ahammed,
D. Aleksandrov,
A. Alici,
A. Alkin,
T. Alt,
I. Altsybeev,
D. Andreou,
A. Andronic,
F. Antinori,
P. Antonioli,
H. Appelshäuser,
R. Arnaldi,
I. C. Arsene,
M. Arslandok,
R. Averbeck,
M. D. Azmi,
X. Bai,
R. Bailhache,
R. Bala,
L. Barioglio,
G. G. Barnaföldi,
L. S. Barnby
, et al. (374 additional authors not shown)
Abstract:
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with th…
▽ More
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with the innermost layers possibly positioned inside the beam pipe. In addition to superior tracking and vertexing capabilities over a wide momentum range down to a few tens of MeV/$c$, the detector will provide particle identification via time-of-flight determination with about 20~ps resolution. In addition, electron and photon identification will be performed in a separate shower detector. The proposed detector is conceived for studies of pp, pA and AA collisions at luminosities a factor of 20 to 50 times higher than possible with the upgraded ALICE detector, enabling a rich physics program ranging from measurements with electromagnetic probes at ultra-low transverse momenta to precision physics in the charm and beauty sector.
△ Less
Submitted 2 May, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.
-
Simple Front End Electronics for Multigap Resistive Plate Chambers
Authors:
W. J. Llope,
T. Nussbaum,
G. Eppley,
J. Velkovska,
T. Chujo,
S. Huang,
B. Love,
H. Valle,
L. Ruan,
Z. Xu,
B. Bonner
Abstract:
A simple circuit for the presentation of the signals from Multi-gap Resistive Plate Chambers (MRPCs) to standard existing digitization electronics is described. The circuit is based on "off-the-shelf" discrete components. An optimization of the values of specific components is required to match the aspects of the MRPCs for the given application. This simple circuit is an attractive option for th…
▽ More
A simple circuit for the presentation of the signals from Multi-gap Resistive Plate Chambers (MRPCs) to standard existing digitization electronics is described. The circuit is based on "off-the-shelf" discrete components. An optimization of the values of specific components is required to match the aspects of the MRPCs for the given application. This simple circuit is an attractive option for the initial signal processing for MRPC prototy** and bench- or beam-testing efforts, as well as for final implementations of small-area Time-of-Flight systems with existing data acquisition systems.
△ Less
Submitted 18 July, 2008;
originally announced July 2008.