-
Extraordinary magnetometry -- a review on extraordinary magnetoresistance
Authors:
Thierry Desire Pomar,
Ricci Erlandsen,
Bowen Zhou,
Leonid Iliushyn,
Rasmus Bjørk,
Dennis Valbjørn Christensen
Abstract:
Extraordinary magnetoresistance (EMR) is a geometric magnetoresistance effect occurring in hybrid devices consisting of a high-mobility material joined by a metal. The change in resistance can exceed 107% at room temperature when a magnetic field of 5 T is applied. Magnetic field sensors based on EMR hold the potential formeasuring weak magnetic fields with an unprecedented sensitivity, yet, to da…
▽ More
Extraordinary magnetoresistance (EMR) is a geometric magnetoresistance effect occurring in hybrid devices consisting of a high-mobility material joined by a metal. The change in resistance can exceed 107% at room temperature when a magnetic field of 5 T is applied. Magnetic field sensors based on EMR hold the potential formeasuring weak magnetic fields with an unprecedented sensitivity, yet, to date this potential is largely unmet. In this work, we provide an extensive review of the current state-of-the-art in EMR sensors with a focus on the hybrid device geometries, the constituent material properties and applications of EMR. We present a direct comparison of the best devices in literature across magnetoresistance, sensitivity and noise equivalent field for different materials and geometric designs. The compilation of studies collected in this review illustrates the extremely rich possibilities for tuning the magnetoresistive behavior varying the device geometry and material properties. In addition, we aim to improve the understanding of the EMR effect and its interplay with geometry and material properties. Finally, we discuss recent trends in the field and future perspectives for EMR.
△ Less
Submitted 8 November, 2022;
originally announced November 2022.
-
Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models
Authors:
Jean-Francois Aubry,
Oscar Bates,
Christian Boehm,
Kim Butts Pauly,
Douglas Christensen,
Carlos Cueto,
Pierre Gelat,
Lluis Guasch,
Jiri Jaros,
Yun **g,
Rebecca Jones,
Ningrui Li,
Patrick Marty,
Hazael Montanaro,
Esra Neufeld,
Samuel Pichardo,
Gianmarco Pinton,
Aki Pulkkinen,
Antonio Stanziola,
Axel Thielscher,
Bradley Treeby,
Elwin van 't Wout
Abstract:
Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numeric…
▽ More
Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
Validity of One-Dimensional QED for a System with Spatial Symmetry
Authors:
Q. Z. Lv,
N. D. Christensen,
Q. Su,
R. Grobe
Abstract:
We examine the accuracy of an intrinsically one-dimensional quantum electrodynamics to predict accurately the forces and charges of a three-dimensional system that has a high degree of symmetry and therefore depends effectively only on a single coordinate. As a test case we analyze two charged capacitor plates that are infinitely extended along two coordinate directions. Using the lowest-order fin…
▽ More
We examine the accuracy of an intrinsically one-dimensional quantum electrodynamics to predict accurately the forces and charges of a three-dimensional system that has a high degree of symmetry and therefore depends effectively only on a single coordinate. As a test case we analyze two charged capacitor plates that are infinitely extended along two coordinate directions. Using the lowest-order fine structure correction to the photon propagator we compute the vacuum's induced charge polarization density and show that the force between the charged plates is increased. Although a one-dimensional theory cannot take the transverse character of the virtual (force-mediating) photons into account, nevertheless it predicts, in lowest order of the fine-structure constant, the Coulomb force law between the plates correctly. However, the quantum correction to the classical result is slightly different between the 1d and 3d theories with the polarization charge density induced from the vacuum underestimated by the 1d approach.
△ Less
Submitted 8 June, 2015;
originally announced June 2015.
-
An optimized magnet for magnetic refrigeration
Authors:
R. Bjørk,
C. R. H. Bahl,
A. Smith,
D. V. Christensen,
N. Pryds
Abstract:
A magnet designed for use in a magnetic refrigeration device is presented. The magnet is designed by applying two general schemes for improving a magnet design to a concentric Halbach cylinder magnet design and dimensioning and segmenting this design in an optimum way followed by the construction of the actual magnet. The final design generates a peak value of 1.24 T, an average flux density of 0.…
▽ More
A magnet designed for use in a magnetic refrigeration device is presented. The magnet is designed by applying two general schemes for improving a magnet design to a concentric Halbach cylinder magnet design and dimensioning and segmenting this design in an optimum way followed by the construction of the actual magnet. The final design generates a peak value of 1.24 T, an average flux density of 0.9 T in a volume of 2 L using only 7.3 L of magnet, and has an average low flux density of 0.08 T also in a 2 L volume. The working point of all the permanent magnet blocks in the design is very close to the maximum energy density. The final design is characterized in terms of a performance parameter, and it is shown that it is one of the best performing magnet designs published for magnetic refrigeration.
△ Less
Submitted 8 October, 2014;
originally announced October 2014.
-
Numerical calculation of classical and non-classical electrostatic potentials
Authors:
Dan Christensen,
Brian Neyenhuis,
Dallin S. Durfee
Abstract:
We present a numerical exercise in which classical and non-classical electrostatic potentials were calculated. The non-classical fields take into account effects due to a possible non-zero photon rest mass. We show that in the limit of small photon rest mass, both the classical and non-classical potential can be found by solving Poisson's equation twice, using the first calculation as a source t…
▽ More
We present a numerical exercise in which classical and non-classical electrostatic potentials were calculated. The non-classical fields take into account effects due to a possible non-zero photon rest mass. We show that in the limit of small photon rest mass, both the classical and non-classical potential can be found by solving Poisson's equation twice, using the first calculation as a source term in the second calculation. Our results support the assumptions in a recent proposal to use ion interferometry to search for a non-zero photon rest mass.
△ Less
Submitted 15 September, 2006;
originally announced September 2006.
-
Testing non-classical theories of electromagnetism with ion interferometry
Authors:
B. Neyenhuis,
D. Christensen,
D. S. Durfee
Abstract:
We discuss using a table-top ion interferometer to search for deviations from Coulomb's inverse-square law. Such deviations would result from non-classical effects such at a non-zero photon rest mass. We discuss the theory behind the proposed measurement, explain which fundamental, experimentally controllable parameters are the relevant figures of merit, and calculate the expected performance of…
▽ More
We discuss using a table-top ion interferometer to search for deviations from Coulomb's inverse-square law. Such deviations would result from non-classical effects such at a non-zero photon rest mass. We discuss the theory behind the proposed measurement, explain which fundamental, experimentally controllable parameters are the relevant figures of merit, and calculate the expected performance of such a device in terms of these parameters. The sensitivity to deviations in the exponent of the inverse-square law is predicted to be a few times $10^{-22}$, an improvement by five orders of magnitude over current experiments. It could measure a non-zero photon rest mass smaller than $9\times10^{-50}$ grams, nearly 100 times smaller than current laboratory experiments.
△ Less
Submitted 18 September, 2007; v1 submitted 30 June, 2006;
originally announced June 2006.