Construction and Test of the Precision Drift Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
W. Blum,
U. Bratzler,
H. Dietl,
S. Kotov,
H. Kroha,
Th. Lagouri,
A. Manz,
A. Ostapchuk,
R. Richter,
S. Schael,
S. Chouridou,
M. Deile,
O. Kortner,
A. Staude,
R. Stroehmer,
T. Trefzger
Abstract:
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire posi…
▽ More
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire positioning accu- racy of 20 ?microns (rms). The feasibility was demonstrated with the full-scale prototype of one of the largest MDT chambers with 432 drift tubes of 3.8 m length. For the ATLAS muon spectrometer, 88 chambers of this type have to be built. The first chamber has been completed with a wire positioning accuracy of 14 microns (rms).
△ Less
Submitted 8 April, 2016;
originally announced April 2016.
-
Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
U. Bratzler,
H. Dietl,
H. Kroha,
Th. Lagouri,
A. Manz,
A. Ostapchuk,
R. Richter,
S. Schael,
S. Chouridou,
M. Deile,
O. Kortner,
A. Staude,
R. Stroehmer,
T. Trefzger
Abstract:
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray me…
▽ More
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray measurements at CERN showed a positioning accuracy of the sense wires in the chamber of better than the required 20 ?microns (rms). The performance of the chamber was studied in a muon beam at CERN. Chamber production for ATLAS now has started.
△ Less
Submitted 7 April, 2016;
originally announced April 2016.
-
A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
Authors:
E. Abat,
J. M. Abdallah,
T. N. Addy,
P. Adragna,
M. Aharrouche,
A. Ahmad,
T. P. A. Akesson,
M. Aleksa,
C. Alexa,
K. Anderson,
A. Andreazza,
F. Anghinolfi,
A. Antonaki,
G. Arabidze,
E. Arik,
T. Atkinson,
J. Baines,
O. K. Baker,
D. Banfi,
S. Baron,
A. J. Barr,
R. Beccherle,
H. P. Beck,
B. Belhorma,
P. J. Bell
, et al. (460 additional authors not shown)
Abstract:
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in…
▽ More
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions im**ing on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
△ Less
Submitted 12 May, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam
Authors:
A. Ahmad,
A. Andreazza,
T. Atkinson,
J. Baines,
A. J. Barr,
R. Beccherle,
P. J. Bell,
J. Bernabeu,
Z. Broklova,
P. A. Bruckman de Renstrom,
D. Cauz,
L. Chevalier,
S. Chouridou,
M. Citterio,
A. Clark,
M. Cobal,
T. Cornelissen,
S. Correard,
M. J. Costa,
D. Costanzo,
S. Cuneo,
M. Dameri,
G. Darbo,
J. B. de Vivie,
B. Di Girolamo
, et al. (104 additional authors not shown)
Abstract:
A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated u…
▽ More
A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated using the known momenta of the beam particles and were shown to yield consistent results among the different alignment approaches. From the residual distributions, it is concluded that the precision attained in the alignment of the silicon modules is of the order of 5 micrometers in their most precise coordinate.
△ Less
Submitted 26 May, 2008;
originally announced May 2008.