-
Testing the data framework for an AI algorithm in preparation for high data rate X-ray facilities
Authors:
Hongwei Chen,
Sathya R. Chitturi,
Rajan Plumley,
Lingjia Shen,
Nathan C. Drucker,
Nicolas Burdet,
Cheng Peng,
Sougata Mardanya,
Daniel Ratner,
Aashwin Mishra,
Chun Hong Yoon,
Sanghoon Song,
Matthieu Chollet,
Gilberto Fabbris,
Mike Dunne,
Silke Nelson,
Mingda Li,
Aaron Lindenberg,
Chun**g Jia,
Youssef Nashed,
Arun Bansil,
Sugata Chowdhury,
Adrian E. Feiguin,
Joshua J. Turner,
Jana B. Thayer
Abstract:
The advent of next-generation X-ray free electron lasers will be capable of delivering X-rays at a repetition rate approaching 1 MHz continuously. This will require the development of data systems to handle experiments at these type of facilities, especially for high throughput applications, such as femtosecond X-ray crystallography and X-ray photon fluctuation spectroscopy. Here, we demonstrate a…
▽ More
The advent of next-generation X-ray free electron lasers will be capable of delivering X-rays at a repetition rate approaching 1 MHz continuously. This will require the development of data systems to handle experiments at these type of facilities, especially for high throughput applications, such as femtosecond X-ray crystallography and X-ray photon fluctuation spectroscopy. Here, we demonstrate a framework which captures single shot X-ray data at the LCLS and implements a machine-learning algorithm to automatically extract the contrast parameter from the collected data. We measure the time required to return the results and assess the feasibility of using this framework at high data volume. We use this experiment to determine the feasibility of solutions for `live' data analysis at the MHz repetition rate.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Single-shot X-ray Absorption Spectroscopy at X-ray Free Electron Lasers
Authors:
M. Harmand,
M. Cammarata,
M. Chollet,
A. G Krygier,
H. T. Lemke,
D. Zhu
Abstract:
X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method. While synchrotrons have large communities of XAS users, its use on X-Ray Free Electron Lasers (XFEL) facilities has been rather limited. At a first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of XFEL sources seem to prevent high-quality XAS measurements without accumulating over…
▽ More
X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method. While synchrotrons have large communities of XAS users, its use on X-Ray Free Electron Lasers (XFEL) facilities has been rather limited. At a first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of XFEL sources seem to prevent high-quality XAS measurements without accumulating over many shots. Here, we demonstrate for the first time the collection of single-shot XAS spectra on an XFEL, with error bars of only a few percent, over tens of eV. We show how this technique can be extended over wider spectral ranges towards Extended X-ray Absorption Fine Structure (EXAFS) measurements, by concatenating a few tens of single-shot measurements. Such results open indisputable perspectives for future femtosecond time resolved XAS studies, especially for transient processes that can be initiated at low repetition rate.
△ Less
Submitted 4 May, 2020;
originally announced May 2020.
-
Speckle correlation as a monitor of X-ray free electron laser induced crystal lattice deformation
Authors:
Rajan Plumley,
Yanwen Sun,
Samuel W Teitelbaum,
Sanghoon Song,
Takahiro Sato,
Matthieu Chollet,
Nan Wang,
Aymeric Robert,
Paul H Fuoss,
Mark Sutton,
Diling Zhu
Abstract:
X-ray free electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpreta…
▽ More
X-ray free electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, we investigate X-FEL beam-induced lattice alterations by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. We show that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.
△ Less
Submitted 17 December, 2019; v1 submitted 13 December, 2019;
originally announced December 2019.
-
Femtosecond laser produced periodic plasma in a colloidal crystal probed by XFEL radiation
Authors:
Nastasia Mukharamova,
Sergey Lazarev,
Janne-Mieke Meijer,
Oleg Yu. Gorobtsov,
Andrej Singer,
Matthieu Chollet,
Michael Bussmann,
Dmitry Dzhigaev,
Yi** Feng,
Marco Garten,
Axel Huebl,
Thomas Kluge,
Ruslan P. Kurta,
Vladimir Lipp,
Robin Santra,
Marcin Sikorski,
Sanghoon Song,
Garth Williams,
Diling Zhu,
Beata Ziaja-Motyka,
Thomas Cowan,
Andrei V. Petukhov,
Ivan A. Vartanyants
Abstract:
With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free- Electron Lasers (XFELs), delivering intense femtosecond X-ray pulses allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present the…
▽ More
With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free- Electron Lasers (XFELs), delivering intense femtosecond X-ray pulses allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present the detailed study of periodic plasma created from the colloidal crystal. Both experimental data and theory modeling show that the periodicity in the sample survives to a large extent the extreme excitation and shock wave propagation inside the colloidal crystal. This feature enables probing the excited crystal, using the powerful Bragg peak analysis, in contrast to the conventional studies of dense plasma created from bulk samples for which probing with Bragg diffraction technique is not possible. X-ray diffraction measurements of excited colloidal crystals may then lead towards a better understanding of matter phase transitions under extreme irradiation conditions.
△ Less
Submitted 9 November, 2019;
originally announced November 2019.
-
Diffraction based Hanbury Brown and Twiss interferometry performed at a hard x-ray free-electron laser
Authors:
O. Yu. Gorobtsov,
N. Mukharamova,
S. Lazarev,
M. Chollet,
D. Zhu,
Y. Feng,
R. P. Kurta,
J. -M. Meijer,
G. Williams,
M. Sikorski,
S. Song,
D. Dzhigaev,
S. Serkez,
A. Singer,
A. V. Petukhov,
I. A. Vartanyants
Abstract:
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns. This is different from the traditional approach when HBT interferometry requires direct beam measurements in absence of the sample. HBT analysis was carried out on the Bragg peaks from the colloidal crystals measured at Linac Coherent Light Source…
▽ More
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns. This is different from the traditional approach when HBT interferometry requires direct beam measurements in absence of the sample. HBT analysis was carried out on the Bragg peaks from the colloidal crystals measured at Linac Coherent Light Source (LCLS). We observed high degree (80%) spatial coherence of the full beam and the pulse duration of the monochromatized beam on the order of 11 fs that is significantly shorter than expected from the electron bunch measurements.
△ Less
Submitted 27 July, 2017;
originally announced July 2017.
-
Optimal pulse processing, pile-up decomposition and applications of silicon drift detectors at LCLS
Authors:
G. Blaj,
C. J. Kenney,
A. Dragone,
G. Carini,
S. Herrmann,
P. Hart,
A. Tomada,
J. Koglin,
G. Haller,
S. Boutet,
M. Messerschmidt,
G. Williams,
M. Chollet,
G. Dakovski,
S. Nelson,
J. Pines,
S. Song,
J. Thayer
Abstract:
Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultra-fast, x-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only severa…
▽ More
Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultra-fast, x-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only several discrete photon energies known a priori, allowing single event decomposition of pile-up and spectroscopic photon counting. We designed a pulse function and demonstrated that the signal amplitude and rise time are obtained for each pulse by fitting, thus removing the need for pulse sha**. By avoiding pulse sha**, rise times of tens of nanoseconds resulted in reduced pulse pile-up and allowed decomposition of remaining pulse pile-up at photon separation times down to hundreds of nanoseconds while yielding time-of-arrival information with precision of 10 nanoseconds. Waveform fitting yields simultaneously high energy resolution and high counting rates (2 orders of magnitude higher than current digital pulse processors). We showed that pile-up spectrum fitting is relatively simple and preferable to pile-up spectrum deconvolution. We developed a photon pile-up statistical model for constant intensity sources, extended it to variable intensity sources (typical for FELs) and used it to fit a complex pile-up spectrum. We subsequently developed a Bayesian pile-up decomposition method that allows decomposing pile-up of single events with up to 6 photons from 6 monochromatic lines with 99% accuracy. The usefulness of SDDs will continue into the x-ray FEL era of science. Their successors, the ePixS hybrid pixel detectors, already offer hundreds of pixels, each with similar performance to an SDD, in a compact, robust and affordable package
△ Less
Submitted 19 March, 2019; v1 submitted 5 June, 2017;
originally announced June 2017.
-
Femtosecond X-Ray Scattering Study of Ultrafast Photoinduced Structural Dynamics in Solvated [Co(terpy)2]2+
Authors:
Elisa Biasin,
Tim Brandt van Driel,
Kasper S. Kjær,
Asmus O. Dohn,
Morten Christensen,
Tobias Harlang,
Pavel Chabera,
Yizhu Liu,
Jens Uhlig,
Mátyás Pápai,
Zoltán Németh,
Robert Hartsock,
Winnie Liang,
Jianxin Zhang,
Roberto Alonso-Mori,
Matthieu Chollet,
James M. Glownia,
Silke Nelson,
Dimosthenis Sokaras,
Tadesse A. Assefa,
Alexander Britz,
Andreas Galler,
Wojciech Gawelda,
Christian Bressler,
Kelly J. Gaffney
, et al. (8 additional authors not shown)
Abstract:
We study the structural dynamics of photoexcited [Co(terpy)2]2+ in an aqueous solution with ultrafast x-ray diffuse scattering experiments conducted at the Linac Coherent Light Source. Through direct comparisons with density functional theory calculations, our analysis shows that the photoexcitation event leads to elongation of the Co-N bonds, followed by coherent Co-N bond length oscillations ari…
▽ More
We study the structural dynamics of photoexcited [Co(terpy)2]2+ in an aqueous solution with ultrafast x-ray diffuse scattering experiments conducted at the Linac Coherent Light Source. Through direct comparisons with density functional theory calculations, our analysis shows that the photoexcitation event leads to elongation of the Co-N bonds, followed by coherent Co-N bond length oscillations arising from the impulsive excitation of a vibrational mode dominated by the symmetrical stretch of all six Co-N bonds. This mode has a period of 0.33 ps and decays on a subpicosecond time scale. We find that the equilibrium bond-elongated structure of the high spin state is established on a single-picosecond time scale and that this state has a lifetime of ~ 7 ps.
△ Less
Submitted 6 July, 2016;
originally announced July 2016.
-
Watching coherent molecular structural dynamics during photoreaction: beyond kinetic description
Authors:
Henrik T. Lemke,
Kasper Skov Kjær,
Robert Hartsock,
Tim Brandt van Driel,
Matthieu Chollet,
J. M. Glownia,
Sanghoon Song,
Diling Zhu,
Elisabetta Pace,
Martin M Nielsen,
Maurizio Benfatto,
Kelly J. Gaffney,
Eric Collet,
Marco Cammarata
Abstract:
A deep understanding of molecular photo-transformations is challenging because of the complex interaction between the configurations of electrons and nuclei. An initial optical excitation dissipates energy into electronic and structural degrees of freedom, often in less than one trillionth (10^-12) of a second. Molecular dynamics induced by photoexcitation have been very successfully studied with…
▽ More
A deep understanding of molecular photo-transformations is challenging because of the complex interaction between the configurations of electrons and nuclei. An initial optical excitation dissipates energy into electronic and structural degrees of freedom, often in less than one trillionth (10^-12) of a second. Molecular dynamics induced by photoexcitation have been very successfully studied with femtosecond optical spectroscopies, but electronic and nuclear dynamics are often very difficult to disentangle. X-ray based spectroscopies can reduce the ambiguity between theoretical models and experimental data, but it is only with the recent development of bright ultrafast X-ray sources, that key information during transient molecular processes can be obtained on their intrinsic timescale. In this letter, Free Electron Laser (FEL) radiation is used to measure ultrafast changes in the X-ray Absorption Near Edge Structure (XANES) during the prototypical photoreaction of a spin crossover compound. We reveal its transformation from the ligand-located electronic photoexcitation to the structural trap** of the high spin state. The results require a description beyond a kinetic model and provide a direct observation of a dynamic breathing of the main structural change. The coherent structural oscillations (period of ~265 fs) in the photoproduct potential lose synchrony within ~330 fs, whereas incoherent motions reveal the energy redistribution and vibrational cooling within ~1.6 ps. We foresee that ultrafast X-ray spectroscopies will provide invaluable insight to understand the complex physics of fundamental light induced phenomena, which are of prime interest in a multitude of chemical, physical and biological processes.
△ Less
Submitted 12 November, 2015; v1 submitted 4 November, 2015;
originally announced November 2015.
-
All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source
Authors:
S. Stoupin,
S. A. Terentyev,
V. D. Blank,
Yu. V. Shvyd'ko,
K. Goetze,
L. Assoufid,
S. N. Polyakov,
M. S. Kuznetsov,
N. V. Kornilov,
J. Katsoudas,
R. Alonso-Mori,
M. Chollet,
Y. Feng,
J. M. Glownia,
H. Lemke,
A. Robert,
S. Song,
M. Sikorski,
D. Zhu
Abstract:
A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fa…
▽ More
A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fabrication, and X-ray characterization of the first and second (300-um-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 X 2 mm2 with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 X 2 mm2 working regions of the crystals.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation
Authors:
Andreas Koch,
Matthew Hart,
Tim Nicholls,
Christian Angelsen,
John Coughlan,
Marcus French,
Steffen Hauf,
Markus Kuster,
Jolanta Sztuk-Dambietz,
Monica Turcato,
Gabriella A. Carini,
Matthieu Chollet,
Sven C. Herrmann,
Henrik T. Lemke,
Silke Nelson,
Sanghoon Song,
Matt Weaver,
Diling Zhu,
Alke Meents,
Pontus Fischer
Abstract:
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides…
▽ More
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides relatively low noise at high speed which results in a high dynamic range of 10^5 photons over an energy range of 5-20 keV. Small scale prototypes of 32x256 pixels (LPD 2-Tile detector) and 256x256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 10^4 at 12 keV with a readout noise equivalent to <1 photon rms in its most sensitive mode.
△ Less
Submitted 7 November, 2013;
originally announced November 2013.