-
Implementation of reflection matrix microscopy: An algorithm perspective
Authors:
Sungsam Kang,
Seokchan Yoon,
Wonshik Choi
Abstract:
Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In this study, we introduce significant advancements in reflection matrix processing algorithms, including logical indexing, power iterations, and low-frequency bl…
▽ More
Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In this study, we introduce significant advancements in reflection matrix processing algorithms, including logical indexing, power iterations, and low-frequency blocking. These enhance the processing speed of aperture synthesis, 3D image reconstruction, and aberration correction by orders of magnitude. Detailed algorithm implementations, along with experimental data, are provided to facilitate the widespread adoption of RMM in various deep-tissue imaging applications.
△ Less
Submitted 2 July, 2024;
originally announced July 2024.
-
Characterization of a graphene-hBN superlattice field effect transistor
Authors:
Won Beom Choi,
Youngoh Son,
Hangyeol Park,
Yungi Jeong,
Junhyeok Oh,
K. Watanabe,
T. Taniguchi,
Joonho Jang
Abstract:
Graphene is a unique platform to naturally host a high quality 2D electron system. With hBN encapsulation to protect the graphene from the noisy environment, it has a potential to realize ultrahigh performance nanodevices, such as photodiodes and transistors. However, absence of a band gap at Dirac point poses challenges in using the system as a useful transistor. In this study, we investigate the…
▽ More
Graphene is a unique platform to naturally host a high quality 2D electron system. With hBN encapsulation to protect the graphene from the noisy environment, it has a potential to realize ultrahigh performance nanodevices, such as photodiodes and transistors. However, absence of a band gap at Dirac point poses challenges in using the system as a useful transistor. In this study, we investigate the functionality of a hBN-aligned monolayer graphene as a field effect transistor (FET). By precisely aligning the hBN and graphene, the band gaps open at the first Dirac point and at the hole-doped induced Dirac point via an interfacial moire potential. To characterize as a submicron scale FET, we fabricated a global bottom gate to tune the density of a conducting channel and a local top gate to switch-off the channel, demonstrating that this system can be tuned at an optimal on/off ratio regime by controlling the gates separately. These findings will present a useful reference point for further development of the FETs based on graphene heterostructures.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
Multiphoton super-resolution imaging via virtual structured illumination
Authors:
Sumin Lim,
Sungsam Kang,
**-Hee Hong,
Youngho **,
Kalpak Gupta,
Moonseok Kim,
Suhyun Kim,
Wonshik Choi,
Seokchan Yoon
Abstract:
Fluorescence imaging in thick biological tissues is challenging due to sample-induced aberration and scattering, which leads to severe degradation of image quality and resolution. Fluorescence imaging in reflection geometry further exacerbates this issue since the point spread function is distorted in both excitation and emission pathways. Here, we propose a novel approach termed adaptive optics v…
▽ More
Fluorescence imaging in thick biological tissues is challenging due to sample-induced aberration and scattering, which leads to severe degradation of image quality and resolution. Fluorescence imaging in reflection geometry further exacerbates this issue since the point spread function is distorted in both excitation and emission pathways. Here, we propose a novel approach termed adaptive optics virtual structured illumination microscopy (AO V-SIM) that enables super-resolution multiphoton imaging through a scattering medium in reflection geometry. Our approach exploits the incoherent reflection matrix obtained using a conventional point-scanning fluorescence microscope with an array detector. We introduce V-SIM super-resolution reconstruction algorithm based on the incoherent reflection matrix. Furthermore, we introduce a software adaptive optics correction algorithm, AO V-SIM, which recovers unattenuated and phase-corrected optical transfer function for both excitation and emission pathways. The effectiveness of our proposed method is experimentally validated through sub-diffraction-limited two-photon fluorescence imaging of various samples in the presence of strong aberration.
△ Less
Submitted 17 April, 2024;
originally announced April 2024.
-
Ptychographic lensless coherent endomicroscopy through a flexible fiber bundle
Authors:
Gil Weinberg,
Munkyu Kang,
Wonjun Choi,
Wonshik Choi,
Ori Katz
Abstract:
Conventional fiber-bundle-based endoscopes allow minimally invasive imaging through flexible multi-core fiber (MCF) bundles by placing a miniature lens at the distal tip and using each core as an imaging pixel. In recent years, lensless imaging through MCFs was made possible by correcting the core-to-core phase distortions pre-measured in a calibration procedure. However, temporally varying wavefr…
▽ More
Conventional fiber-bundle-based endoscopes allow minimally invasive imaging through flexible multi-core fiber (MCF) bundles by placing a miniature lens at the distal tip and using each core as an imaging pixel. In recent years, lensless imaging through MCFs was made possible by correcting the core-to-core phase distortions pre-measured in a calibration procedure. However, temporally varying wavefront distortions, for instance, due to dynamic fiber bending, pose a challenge for such approaches. Here, we demonstrate a coherent lensless imaging technique based on intensity-only measurements insensitive to core-to-core phase distortions. We leverage a ptychographic reconstruction algorithm to retrieve the phase and amplitude profiles of reflective objects placed at a distance from the fiber tip, using as input a set of diffracted intensity patterns reflected from the object when the illumination is scanned over the MCF cores. Our approach thus utilizes an acquisition process equivalent to confocal microendoscopy, only replacing the single detector with a camera.
△ Less
Submitted 31 January, 2024;
originally announced February 2024.
-
Quantitative assessment of dosimetric effect of using alternative OAR delineations in treatment planning as functions of delineations, setup uncertainty and planning techniques using an alternative truth assessment method
Authors:
M. N. H. Rashad,
Abishek Karki,
Jason Czak,
Victor Gabriel Alves,
Hamidreza Nourzadeh,
Wook** Choi,
Jeffrey V Siebers
Abstract:
Purpose: This study aims to quantify the variation in dose-volume histogram (DVH) and normal tissue complication probability(NTCP) metrics for head-and-neck (HN) cancer patients when alternative organ-at-risk(OAR) delineations are used for treatment planning and for treatment plan evaluation. We particularly focus on the effects of daily patient positioning/setup variations(SV) in relation to trea…
▽ More
Purpose: This study aims to quantify the variation in dose-volume histogram (DVH) and normal tissue complication probability(NTCP) metrics for head-and-neck (HN) cancer patients when alternative organ-at-risk(OAR) delineations are used for treatment planning and for treatment plan evaluation. We particularly focus on the effects of daily patient positioning/setup variations(SV) in relation to treatment technique and delineation variability.
Materials and Methods: We generated two-arc VMAT, 5-beam IMRT, and 9-beam IMRT treatment plans for a cohort of 209 HN patients. These plans incorporated five different OAR delineation sets, including manual and four automated algorithms. Each treatment plan was assessed under various simulated per-fraction patient setup uncertainties, evaluating the potential clinical impacts through DVH and NTCP metrics.
Results: The study demonstrates that increasing SV generally reduces differences in DVH metrics between alternative delineations. However, in contrast, differences in NTCP metrics tend to increase with higher setup variability. This pattern is observed consistently across different treatment plans and delineator combinations, illustrating the intricate relationship between SV and delineation accuracy. Additionally, the need for delineation accuracy in treatment planning is shown to be case-specific and dependent on factors beyond geometric variations.
Conclusions: The findings highlight the necessity for comprehensive Quality Assurance programs in radiotherapy, incorporating both dosimetric impact analysis and geometric variation assessment to ensure optimal delineation quality. The study emphasizes the complex dynamics of treatment planning in radiotherapy, advocating for personalized, case-specific strategies in clinical practice to enhance patient care quality and efficacy in the face of varying SV and delineation accuracies.
△ Less
Submitted 10 January, 2024;
originally announced January 2024.
-
Nonlinear concentric water waves of moderate amplitude
Authors:
Nerijus Sidorovas,
Dmitri Tseluiko,
Wooyoung Choi,
Karima Khusnutdinova
Abstract:
We consider the outward-propagating nonlinear concentric water waves within the scope of the 2D Boussinesq system. The problem is axisymmetric, and we derive the slow radius versions of the cylindrical Korteweg - de Vries (cKdV) and extended cKdV (ecKdV) models. Numerical runs are initially performed using the full axisymmetric Boussinesq system. At some distance away from the origin, we use the n…
▽ More
We consider the outward-propagating nonlinear concentric water waves within the scope of the 2D Boussinesq system. The problem is axisymmetric, and we derive the slow radius versions of the cylindrical Korteweg - de Vries (cKdV) and extended cKdV (ecKdV) models. Numerical runs are initially performed using the full axisymmetric Boussinesq system. At some distance away from the origin, we use the numerical solution of the Boussinesq system as the "initial condition" for the derived cKdV and ecKdV models. We then compare the evolution of the waves as described by both reduced models and the direct numerical simulations of the axisymmetric Boussinesq system. The main conclusion of the paper is that the extended cKdV model provides a much more accurate description of the waves and extends the range of validity of the weakly-nonlinear modelling to the waves of moderate amplitude.
△ Less
Submitted 28 October, 2023;
originally announced October 2023.
-
Experimental Realization of Entangled Coherent States in Two-dimensional Harmonic Oscillators of a Trapped Ion
Authors:
Honggi Jeon,
Jiyong Kang,
Jaeun Kim,
Wonhyeong Choi,
Kyunghye Kim,
Taehyun Kim
Abstract:
Entangled coherent states play pivotal roles in various fields such as quantum computation, quantum communication, and quantum sensing. We experimentally demonstrate the generation of entangled coherent states with the two-dimensional motion of a trapped ion system. Using Raman transitions with appropriate detunings, we simultaneously drive the red and blue sidebands of the two transverse axes of…
▽ More
Entangled coherent states play pivotal roles in various fields such as quantum computation, quantum communication, and quantum sensing. We experimentally demonstrate the generation of entangled coherent states with the two-dimensional motion of a trapped ion system. Using Raman transitions with appropriate detunings, we simultaneously drive the red and blue sidebands of the two transverse axes of a single trapped ion and observe multi-periodic entanglement and disentanglement of its spin and two-dimensional motion. Then, by measuring the spin state, we herald entangled coherent states of the transverse motions of the trapped ion and observe the corresponding modulation in the parity of the phonon distribution of one of the harmonic oscillators. Lastly, we trap two ions in a linear chain and realize Molmer-Sorensen gate using two-dimensional motion.
△ Less
Submitted 1 May, 2023;
originally announced May 2023.
-
Synthetic aperture phase imaging of second harmonic generation field with computational adaptive optics
Authors:
Jungho Moon,
Sungsam Kang,
** Hee Hong,
Seokchan Yoon,
Wonshik Choi
Abstract:
Second-harmonic generation (SHG) microscopy provides label-free imaging of biological tissues with unique contrast mechanisms, but its resolution is limited by the diffraction limit. Here, we present the first experimental demonstration of super-resolution quantitative phase imaging of the SHG field based on synthetic aperture Fourier holographic microscopy. We discuss the mathematical model of sy…
▽ More
Second-harmonic generation (SHG) microscopy provides label-free imaging of biological tissues with unique contrast mechanisms, but its resolution is limited by the diffraction limit. Here, we present the first experimental demonstration of super-resolution quantitative phase imaging of the SHG field based on synthetic aperture Fourier holographic microscopy. We discuss the mathematical model of synthetic-aperture imaging of SHG fields, as well as the computational adaptive optics technique for correcting sample-induced aberration. We demonstrate proof-of-concept experiments where SHG targets are embedded within a thick scattering medium to validate the performance of the proposed imaging technique. It is shown to be able to overcome the conventional Abbe diffraction limit even in the complex aberrations and strong multiple scattering. We also demonstrate SHG-based super-resolution deep-tissue phase imaging of ex-vivo zebrafish muscle tissue.
△ Less
Submitted 27 April, 2023;
originally announced April 2023.
-
Tracing multiple scattering trajectories for deep optical imaging in scattering media
Authors:
Sungsam Kang,
Yongwoo Kwon,
Hojun Lee,
Seho Kim,
** Hee Hong,
Seokchan Yoon,
Wonshik Choi
Abstract:
Multiple light scattering hampers imaging objects in complex scattering media. Approaches used in real practices mainly aim to filter out multiple scattering obscuring the ballistic waves that travel straight through the scattering medium. Here, we propose a method that makes the deterministic use of multiple scattering for microscopic imaging of an object embedded deep within scattering media. Th…
▽ More
Multiple light scattering hampers imaging objects in complex scattering media. Approaches used in real practices mainly aim to filter out multiple scattering obscuring the ballistic waves that travel straight through the scattering medium. Here, we propose a method that makes the deterministic use of multiple scattering for microscopic imaging of an object embedded deep within scattering media. The proposed method finds a stack of multiple complex phase plates that generate similar light trajectories as the original scattering medium. By implementing the inverse scattering using the identified phase plates, our method rectifies multiple scattering and amplifies ballistic waves by almost 600 times, which leads to a substantial increase in imaging depth. Our study marks an important milestone in solving the longstanding high-order inverse scattering problems.
△ Less
Submitted 19 February, 2023;
originally announced February 2023.
-
Directional self-propelled transport of coalesced droplets on a superhydrophilic cylindrical wire
Authors:
Leyun Feng,
Youhua Jiang,
Christian Machado,
Wonjae Choi,
Neelesh A. Patankar,
Kyoo-Chul Park
Abstract:
Droplets coalescing on flat surfaces tend to end up with the smaller droplet migrating into the larger one. We report a counter-intuitive droplet coalescence pattern on a superhydrophilic cylindrical wire, where the larger droplet is pulled toward the smaller one. Consequently, the center of the combined mass significantly moves toward, often beyond, the original location of the smaller droplet. T…
▽ More
Droplets coalescing on flat surfaces tend to end up with the smaller droplet migrating into the larger one. We report a counter-intuitive droplet coalescence pattern on a superhydrophilic cylindrical wire, where the larger droplet is pulled toward the smaller one. Consequently, the center of the combined mass significantly moves toward, often beyond, the original location of the smaller droplet. This phenomenon occurs primarily because the viscous friction that a droplet experiences on a cylindrical wire is not positively correlated with the size of the droplet, unlike the droplets coalescing on flat surfaces. We conducted a dimensional analysis based on a mass-spring-damper (MSD) model. Our model predicts a variety of coalescence patterns as a function of the ratio between droplet sizes, and the prediction matches the experimental observation.
△ Less
Submitted 20 November, 2022;
originally announced November 2022.
-
Acousto-optic volumetric gating for reflection-mode deep optical imaging within a scattering medium
Authors:
Hakseok Ko,
Junghoon Kim,
**-Hee Hong,
Junyeob Cheon,
Seungwoo Lee,
Mooseok Jang,
Wonshik Choi
Abstract:
The imaging depth of deep-tissue optical microscopy is governed by the performance of the gating operation that suppresses the multiply scattered waves obscuring the ballistic waves. Although various gating operations based on confocal, time-resolved/coherence-gated, and polarization-selective detections have proven to be effective, each has its own limitation; certain types of multiply scattered…
▽ More
The imaging depth of deep-tissue optical microscopy is governed by the performance of the gating operation that suppresses the multiply scattered waves obscuring the ballistic waves. Although various gating operations based on confocal, time-resolved/coherence-gated, and polarization-selective detections have proven to be effective, each has its own limitation; certain types of multiply scattered waves can bypass the gating. Here, we propose a method, volumetric gating, that introduces ultrasound focus to confocal reflectance imaging to suppress the multiply scattered waves traveling outside the ultrasonic focal volume. The volumetric gating axially rejects the multiply scattered wave traveling to a depth shallower than the object plane while suppressing the deeper penetrating portion that travels across the object plane outside the transversal extent of the ultrasonic focus of 30${\times}$90$ μm^2$. These joint gating actions along the axial and lateral directions attenuate the multiply scattered waves by a factor of 1/1000 or smaller, thereby extending the imaging depth to 12.1 times the scattering mean free path while maintaining the diffraction-limited resolution of 1.5 $μ$m. We demonstrated an increase in the imaging depth and contrast for internal tissue imaging of mouse colon and small intestine through their outer walls. We further developed theoretical and experimental frameworks to characterize the axial distribution of light trajectories inside scattering media. The volumetric gating will serve as an important addition to deep-tissue imaging modalities and a useful tool for studying wave propagation in scattering media.
△ Less
Submitted 26 October, 2022;
originally announced November 2022.
-
Exploiting volumetric wave correlation for enhanced depth imaging in scattering medium
Authors:
Ye-Ryoung Lee,
Dong-Young Kim,
Yonghyeon Jo,
Moonseok Kim,
Wonshik Choi
Abstract:
Imaging an object embedded within a scattering medium requires the correction of complex sample-induced wave distortions. Existing approaches have been designed to resolve them by optimizing signal waves recorded in each 2D image. Here, we present a volumetric image reconstruction framework that merges two fundamental degrees of freedom, the wavelength and propagation angles of light waves, based…
▽ More
Imaging an object embedded within a scattering medium requires the correction of complex sample-induced wave distortions. Existing approaches have been designed to resolve them by optimizing signal waves recorded in each 2D image. Here, we present a volumetric image reconstruction framework that merges two fundamental degrees of freedom, the wavelength and propagation angles of light waves, based on the object momentum conservation principle. On this basis, we propose methods for exploiting the correlation of signal waves from volumetric images to better cope with multiple scattering. By constructing experimental systems scanning both wavelength and illumination angle of the light source, we demonstrated a 32-fold increase in the use of signal waves compared with that of existing 2D-based approaches and achieved ultrahigh volumetric resolution (lateral resolution: 0.41 um, axial resolution: 0.60 um) even within complex scattering medium owing to the optimal coherent use of the extremely broad spectral bandwidth (225 nm).
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Wave propagation dynamics inside a complex scattering medium by the temporal control of backscattered waves
Authors:
Ye-Ryoung Lee,
Wonjun Choi,
Seungwon Jeong,
Sungsam Kang,
Dong-Young Kim,
Wonshik Choi
Abstract:
Sha** the wavefront of an incident wave to a complex scattering medium has demonstrated interesting possibilities, such as sub-diffraction wave focusing and enhancing light energy delivery. However, wavefront sha** has mainly been based on the control of transmitted waves that are inaccessible in most realistic applications. Here, we investigate the effect of maximizing the backscattered waves…
▽ More
Sha** the wavefront of an incident wave to a complex scattering medium has demonstrated interesting possibilities, such as sub-diffraction wave focusing and enhancing light energy delivery. However, wavefront sha** has mainly been based on the control of transmitted waves that are inaccessible in most realistic applications. Here, we investigate the effect of maximizing the backscattered waves at a specific flight time on wave propagation dynamics and energy transport. We find both experimentally and numerically that the maximization at a short flight time focuses waves on the particles constituting the scattering medium, leading to the attenuation of the wave transport. On the contrary, maximization at a long flight time induces constructive wave interference inside the medium and thus enhances wave transport. We provide a theoretical model explaining this interesting transition behavior based on wave correlation. Our study provides a fundamental understanding of the effect of wave control on internal wave dynamics.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
KATRIN: Status and Prospects for the Neutrino Mass and Beyond
Authors:
M. Aker,
M. Balzer,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
M. Biassoni,
B. Bieringer,
F. Block,
S. Bobien,
L. Bombelli,
D. Bormann,
B. Bornschein,
L. Bornschein,
M. Böttcher,
C. Brofferio,
C. Bruch,
T. Brunst,
T. S. Caldwell,
M. Carminati,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
O. Cremonesi
, et al. (137 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a su…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.
△ Less
Submitted 16 June, 2023; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Roadmap on Wavefront Sha** and deep imaging in complex media
Authors:
Sylvain Gigan,
Ori Katz,
Hilton B. de Aguiar,
Esben Ravn Andresen,
Alexandre Aubry,
Jacopo Bertolotti,
Emmanuel Bossy,
Dorian Bouchet,
Joshua Brake,
Sophie Brasselet,
Yaron Bromberg,
Hui Cao,
Thomas Chaigne,
Zhongtao Cheng,
Wonshik Choi,
Tomáš Čižmár,
Meng Cui,
Vincent R Curtis,
Hugo Defienne,
Matthias Hofer,
Ryoichi Horisaki,
Roarke Horstmeyer,
Na Ji,
Aaron K. LaViolette,
Jerome Mertz
, et al. (20 additional authors not shown)
Abstract:
The last decade has seen the development of a wide set of tools, such as wavefront sha**, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tiss…
▽ More
The last decade has seen the development of a wide set of tools, such as wavefront sha**, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tissues. This roadmap highlights several key aspects of this fast develo** field, and some of the challenges and opportunities ahead.
△ Less
Submitted 29 November, 2021;
originally announced November 2021.
-
Ionic Sieving Through One-Atom-Thick 2D Material Enables Analog Nonvolatile Memory for Neuromorphic Computing
Authors:
Revannath Dnyandeo Nikam,
Jongwon Lee,
Wooseok Choi,
Writam Banerjee,
Myonghoon Kwak,
Manoj Yadav,
Hyunsang Hwang
Abstract:
The first report on ion transport through atomic sieves of atomically-thin 2D material is provided to solve critical limitations of electrochemical random-access memory (ECRAM) devices.
The first report on ion transport through atomic sieves of atomically-thin 2D material is provided to solve critical limitations of electrochemical random-access memory (ECRAM) devices.
△ Less
Submitted 30 September, 2021;
originally announced September 2021.
-
High-throughput volumetric adaptive optical imaging using compressed time-reversal matrix
Authors:
Hojun Lee,
Seokchan Yoon,
Pascal Loohuis,
** Hee Hong,
Sungsam Kang,
Wonshik Choi
Abstract:
Deep-tissue optical imaging suffers from the reduction of resolving power due to tissue-induced optical aberrations and multiple scattering noise. Reflection matrix approaches recording the maps of backscattered waves for all the possible orthogonal input channels have provided formidable solutions for removing severe aberrations and recovering the ideal diffraction-limited spatial resolution with…
▽ More
Deep-tissue optical imaging suffers from the reduction of resolving power due to tissue-induced optical aberrations and multiple scattering noise. Reflection matrix approaches recording the maps of backscattered waves for all the possible orthogonal input channels have provided formidable solutions for removing severe aberrations and recovering the ideal diffraction-limited spatial resolution without relying on fluorescence labeling and guide stars. However, measuring the full input-output response of the tissue specimen is time-consuming, making the real-time image acquisition difficult. Here, we present the use of a time-reversal matrix, instead of the reflection matrix, for fast high-resolution volumetric imaging of a mouse brain. The time-reversal matrix reduces two-way problem to one-way problem, which effectively relieves the requirement for the coverage of input channels. Using a newly developed aberration correction algorithm designed for the time-reversal matrix, we demonstrated the correction of complex aberrations using as small as 2 % of the complete basis while maintaining the image reconstruction fidelity comparable to the fully sampled reflection matrix. Due to nearly 100-fold reduction in the matrix recording time, we could achieve real-time aberration-correction imaging for a field of view of 40 x 40 microns (176 x 176 pixels) at a frame rate of 80 Hz. Furthermore, we demonstrated high-throughput volumetric adaptive optical imaging of a mouse brain by recording a volume of 128 x 128 x 125 microns (568 x 568 x 125 voxels) in 3.58 s, correcting tissue aberrations at each and every 1-micron depth section, and visualizing myelinated axons with a lateral resolution of 0.45 microns and an axial resolution of 2 microns.
△ Less
Submitted 14 September, 2021;
originally announced September 2021.
-
OARnet: Automated organs-at-risk delineation in Head and Neck CT images
Authors:
Mumtaz Hussain Soomro,
Hamidreza Nourzadeh,
Victor Gabriel Leandro Alves,
Wook** Choi,
Jeffrey V. Siebers
Abstract:
A 3D deep learning model (OARnet) is developed and used to delineate 28 H&N OARs on CT images. OARnet utilizes a densely connected network to detect the OAR bounding-box, then delineates the OAR within the box. It reuses information from any layer to subsequent layers and uses skip connections to combine information from different dense block levels to progressively improve delineation accuracy. T…
▽ More
A 3D deep learning model (OARnet) is developed and used to delineate 28 H&N OARs on CT images. OARnet utilizes a densely connected network to detect the OAR bounding-box, then delineates the OAR within the box. It reuses information from any layer to subsequent layers and uses skip connections to combine information from different dense block levels to progressively improve delineation accuracy. Training uses up to 28 expert manual delineated (MD) OARs from 165 CTs. Dice similarity coefficient (DSC) and the 95th percentile Hausdorff distance (HD95) with respect to MD is assessed for 70 other CTs. Mean, maximum, and root-mean-square dose differences with respect to MD are assessed for 56 of the 70 CTs. OARnet is compared with UaNet, AnatomyNet, and Multi-Atlas Segmentation (MAS). Wilcoxon signed-rank tests using 95% confidence intervals are used to assess significance. Wilcoxon signed ranked tests show that, compared with UaNet, OARnet improves (p<0.05) the DSC (23/28 OARs) and HD95 (17/28). OARnet outperforms both AnatomyNet and MAS for DSC (28/28) and HD95 (27/28). Compared with UaNet, OARnet improves median DSC up to 0.05 and HD95 up to 1.5mm. Compared with AnatomyNet and MAS, OARnet improves median (DSC, HD95) by up to (0.08, 2.7mm) and (0.17, 6.3mm). Dosimetrically, OARnet outperforms UaNet (Dmax 7/28; Dmean 10/28), AnatomyNet (Dmax 21/28; Dmean 24/28), and MAS (Dmax 22/28; Dmean 21/28). The DenseNet architecture is optimized using a hybrid approach that performs OAR-specific bounding box detection followed by feature recognition. Compared with other auto-delineation methods, OARnet is better than or equal to UaNet for all but one geometric (Temporal Lobe L, HD95) and one dosimetric (Eye L, mean dose) endpoint for the 28 H&N OARs, and is better than or equal to both AnatomyNet and MAS for all OARs.
△ Less
Submitted 23 November, 2021; v1 submitted 31 August, 2021;
originally announced August 2021.
-
Color of Copper/Copper oxide
Authors:
Su Jae Kim,
Seonghoon Kim,
Jegon Lee,
Youngjae Jo,
Yu-Seong Seo,
Myounghoon Lee,
Yousil Lee,
Chae Ryong Cho,
Jong-pil Kim,
Miyeon Cheon,
Jungseek Hwang,
Yong In Kim,
Young-Hoon Kim,
Young-Min Kim,
Aloysius Soon,
Myunghwan Choi,
Woo Seok Choi,
Se-Young Jeong,
Young Hee Lee
Abstract:
Stochastic inhomogeneous oxidation is an inherent characteristic of copper (Cu), often hindering color tuning and bandgap engineering of oxides. Coherent control of the interface between metal and metal oxide remains unresolved. We demonstrate coherent propagation of an oxidation front in single-crystal Cu thin film to achieve a full-color spectrum for Cu by precisely controlling its oxide-layer t…
▽ More
Stochastic inhomogeneous oxidation is an inherent characteristic of copper (Cu), often hindering color tuning and bandgap engineering of oxides. Coherent control of the interface between metal and metal oxide remains unresolved. We demonstrate coherent propagation of an oxidation front in single-crystal Cu thin film to achieve a full-color spectrum for Cu by precisely controlling its oxide-layer thickness. Grain boundary-free and atomically flat films prepared by atomic-sputtering epitaxy allow tailoring of the oxide layer with an abrupt interface via heat treatment with a suppressed temperature gradient. Color tuning of nearly full-color RGB indices is realized by precise control of oxide-layer thickness; our samples covered ~50.4% of the sRGB color space. The color of copper/copper oxide is realized by the reconstruction of the quantitative yield color from oxide pigment (complex dielectric functions of Cu2O) and light-layer interference (reflectance spectra obtained from the Fresnel equations) to produce structural color. We further demonstrate laser-oxide lithography with micron-scale linewidth and depth through local phase transformation to oxides embedded in the metal, providing spacing necessary for semiconducting transport and optoelectronics functionality.
△ Less
Submitted 15 July, 2021;
originally announced July 2021.
-
Video-Streaming Biomedical Implants using Ultrasonic Waves for Communication
Authors:
Gizem Tabak,
Jae Won Choi,
Rita J. Miller,
Michael L. Oelze,
Andrew C. Singer
Abstract:
The use of wireless implanted medical devices (IMDs) is growing because they facilitate continuous monitoring of patients during normal activities, simplify medical procedures required for data retrieval and reduce the likelihood of infection associated with trailing wires. However, most of the state-of-the-art IMDs are passive and offline devices. One of the key obstacles to an active and online…
▽ More
The use of wireless implanted medical devices (IMDs) is growing because they facilitate continuous monitoring of patients during normal activities, simplify medical procedures required for data retrieval and reduce the likelihood of infection associated with trailing wires. However, most of the state-of-the-art IMDs are passive and offline devices. One of the key obstacles to an active and online IMD is the infeasibility of real-time, high-quality video broadcast from the IMD. Such broadcast would help develop innovative devices such as a video-streaming capsule endoscopy (CE) pill with therapeutic intervention capabilities. State-of-the-art IMDs employ radio-frequency electromagnetic waves for information transmission. However, high attenuation of RF-EM waves in tissues and federal restrictions on the transmit power and operable bandwidth lead to fundamental performance constraints for IMDs employing RF links, and prevent achieving high data rates that could accomodate video broadcast. In this work, ultrasonic waves were used for video transmission and broadcast through biological tissues. The proposed proof-of-concept system was tested on a porcine intestine ex vivo and a rabbit in vivo. It was demonstrated that using a millimeter-sized, implanted biocompatible transducer operating at 1.1-1.2 MHz, it was possible to transmit endoscopic video with high resolution (1280 pixels by 720 pixels) through porcine intestine wrapped with bacon, and to broadcast standard definition (640 pixels by 480 pixels) video near real-time through rabbit abdomen in vivo. A media repository that includes experimental demonstrations and media files accompanies this paper. The accompanying media repository can be found at this link: https://bit.ly/3wuc7tk.
△ Less
Submitted 27 June, 2021; v1 submitted 25 June, 2021;
originally announced June 2021.
-
Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger
, et al. (110 additional authors not shown)
Abstract:
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectromet…
▽ More
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $β$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $σ(m_ν^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
The JSNS^2 Detector
Authors:
S. Ajimura,
M. Botran,
J. H. Choi,
J. W. Choi,
M. K. Cheoun,
T. Dodo,
H. Furuta,
J. Goh,
K. Haga,
M. Harada,
S. Hasegawa,
Y. Hino,
T. Hiraiwa,
H. I. Jang,
J. S. Jang,
M. C. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
J. R. Jordan,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim
, et al. (41 additional authors not shown)
Abstract:
The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator det…
▽ More
The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.
△ Less
Submitted 24 August, 2021; v1 submitted 27 April, 2021;
originally announced April 2021.
-
Human Brain Map** with Multi-Thousand Channel PtNRGrids Resolves Novel Spatiotemporal Dynamics
Authors:
Youngbin Tchoe,
Andrew M. Bourhis,
Daniel R. Cleary,
Brittany Stedelin,
Jihwan Lee,
Karen J. Tonsfeldt,
Erik C. Brown,
Dominic Siler,
Angelique C. Paulk,
Jimmy C. Yang,
Hongseok Oh,
Yun Goo Ro,
Woo** Choi,
Keundong Lee,
Samantha Russman,
Mehran Ganji,
Ian Galton,
Sharona Ben-Haim,
Ahmed M. Raslan,
Shadi A. Dayeh
Abstract:
Electrophysiological devices are critical for map** eloquent and diseased brain regions and for therapeutic neuromodulation in clinical settings and are extensively utilized for research in brain-machine interfaces. However, the existing devices are often limited in either spatial resolution or cortical coverage, even including those with thousands of channels used in animal experiments. Here, w…
▽ More
Electrophysiological devices are critical for map** eloquent and diseased brain regions and for therapeutic neuromodulation in clinical settings and are extensively utilized for research in brain-machine interfaces. However, the existing devices are often limited in either spatial resolution or cortical coverage, even including those with thousands of channels used in animal experiments. Here, we developed scalable manufacturing processes and dense connectorization to achieve reconfigurable thin-film, multi-thousand channel neurophysiological recording grids using platinum-nanorods (PtNRGrids). With PtNRGrids, we have achieved a multi-thousand channel array of small (30 μm) contacts with low impedance, providing unparalleled spatial and temporal resolution over a large cortical area. We demonstrate that PtNRGrids can resolve sub-millimeter functional organization of the barrel cortex in anesthetized rats that captured the histochemically-demonstrated structure. In the clinical setting, PtNRGrids resolved fine, complex temporal dynamics from the cortical surface in an awake human patient performing gras** tasks. Additionally, the PtNRGrids identified the spatial spread and dynamics of epileptic discharges in a patient undergoing epilepsy surgery at 1 mm spatial resolution, including activity induced by direct electrical stimulation. Collectively, these findings demonstrate the power of the PtNRGrids to transform clinical map** and research with brain-machine interfaces and highlights a path toward novel therapeutics.
△ Less
Submitted 19 August, 2021; v1 submitted 16 March, 2021;
originally announced March 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Analysis methods for the first KATRIN neutrino-mass measurement
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
K. Blaum,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
D. Díaz Barrero,
K. Debowski,
M. Deffert,
M. Descher,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (104 additional authors not shown)
Abstract:
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, inte…
▽ More
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, integrating spectrometer for energy analysis. A silicon detector counts $β$ electrons above the energy threshold of the spectrometer, so that a scan of the thresholds produces a precise measurement of the high-energy spectral tail. After detailed theoretical studies, simulations, and commissioning measurements, extending from the molecular final-state distribution to inelastic scattering in the source to subtleties of the electromagnetic fields, our independent, blind analyses allow us to set an upper limit of 1.1 eV on the neutrino-mass scale at a 90\% confidence level. This first result, based on a few weeks of running at a reduced source intensity and dominated by statistical uncertainty, improves on prior limits by nearly a factor of two. This result establishes an analysis framework for future KATRIN measurements, and provides important input to both particle theory and cosmology.
△ Less
Submitted 12 May, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
Fourier holographic endoscopy for label-free imaging through a narrow and curved passage
Authors:
Wonjun Choi,
Munkyu Kang,
** Hee Hong,
Ori Katz,
Youngwoon Choi,
Wonshik Choi
Abstract:
Ultrathin lensless fibre endoscopes offer minimally invasive investigation, but they mostly operate as a rigid type due to the need for prior calibration of a fibre probe. Furthermore, most implementations work in fluorescence mode rather than label-free imaging mode, making them unsuitable for medicine and industry. Herein, we report a fully flexible ultrathin fibre endoscope taking 3D holographi…
▽ More
Ultrathin lensless fibre endoscopes offer minimally invasive investigation, but they mostly operate as a rigid type due to the need for prior calibration of a fibre probe. Furthermore, most implementations work in fluorescence mode rather than label-free imaging mode, making them unsuitable for medicine and industry. Herein, we report a fully flexible ultrathin fibre endoscope taking 3D holographic images of unstained tissues with 0.87-μm spatial resolution. Using a bare fibre bundle as thin as 200-μm diameter, we design a lensless Fourier holographic imaging configuration to selectively detect weak reflections from biological tissues, a critical step for stain-free reflectance imaging. A unique algorithm is developed for calibration-free holographic image reconstruction, allowing us to image through a narrow and curved passage regardless of fibre bending. We demonstrate endoscopic reflectance imaging of unstained rat intestine tissues that are completely invisible to conventional endoscopes. The proposed endoscope will expedite more accurate and earlier diagnosis than before with minimal complications.
△ Less
Submitted 22 October, 2020;
originally announced October 2020.
-
Super-Heavy Ions Acceleration Driven by Ultrashort Laser Pulses at Ultrahigh Intensity
Authors:
Pengjie Wang,
Zheng Gong,
Seong Geun Lee,
Yinren Shou,
Yixing Geng,
Cheonha Jeon,
I Jong Kim,
Hwang Woon Lee,
** Woo Yoon,
Jae Hee Sung,
Seong Ku Lee,
Defeng Kong,
Jianbo Liu,
Zhusong Mei,
Zhengxuan Cao,
Zhuo Pan,
Il Woo Choi,
Xueqing Yan,
Chang Hee Nam,
Wenjun Ma
Abstract:
The acceleration of super-heavy ions (SHIs) from plasmas driven by ultrashort (tens of femtoseconds) laser pulses is a challenging topic waiting for breakthrough. The detecting and controlling of the ionization process, and the adoption of the optimal acceleration scheme are crucial for the generation of highly energetic SHIs. Here, we report the experimental results on the generation of deeply io…
▽ More
The acceleration of super-heavy ions (SHIs) from plasmas driven by ultrashort (tens of femtoseconds) laser pulses is a challenging topic waiting for breakthrough. The detecting and controlling of the ionization process, and the adoption of the optimal acceleration scheme are crucial for the generation of highly energetic SHIs. Here, we report the experimental results on the generation of deeply ionized super-heavy ions (Au) with unprecedented energy of 1.2 GeV utilizing ultrashort laser pulses (22 fs) at the intensity of 10^22 W/cm2. A novel self-calibrated diagnostic method was developed to acquire the absolute energy spectra and charge state distributions of Au ions abundant at the charge state of 51+ and reaching up to 61+. The measured charge state distributions supported by 2D particle-in-cell simulations serves as an additional tool to inspect the ionization dynamics associated with SHI acceleration, revealing that the laser intensity is the crucial parameter for the acceleration of Au ions over the pulse duration. The use of double-layer targets results in a prolongation of the acceleration time without sacrificing the strength of acceleration field, which is highly favorable for the generation of high-energy super heavy ions.
△ Less
Submitted 15 April, 2021; v1 submitted 21 August, 2020;
originally announced August 2020.
-
Scalable near-infrared graphene plasmonic resonators exhibiting strong non-local and electron quantization effects
Authors:
Joel. F. Siegel,
Jonathan H. Dwyer,
Anjali Suresh,
Nathaniel S. Safron,
Margaret Fortman,
Chenghao Wan,
Jonathan W. Choi,
Wei Wei,
Vivek Saraswat,
Wyatt A. Behn,
Mikhail A. Kats,
Michael S. Arnold,
Padma Gopalan,
Victor W. Brar
Abstract:
Graphene plasmonic resonators have been broadly studied in the terahertz and mid-infrared ranges because of their electrical tunability and large confinement factors which can enable dramatic enhancement of light-matter coupling. In this work, we demonstrate that the characteristic scaling laws of graphene plasmons change for smaller (< 40 nm) plasmonic wavelengths, expanding the operational frequ…
▽ More
Graphene plasmonic resonators have been broadly studied in the terahertz and mid-infrared ranges because of their electrical tunability and large confinement factors which can enable dramatic enhancement of light-matter coupling. In this work, we demonstrate that the characteristic scaling laws of graphene plasmons change for smaller (< 40 nm) plasmonic wavelengths, expanding the operational frequencies of graphene plasmonic resonators into the near-infrared (NIR) and modifying their optical confinement properties. We utilize a novel bottom-up block copolymer lithography method that substantially improves upon top-down methods to create resonators as narrow as 12 nm over centimeter-scale areas. Measurements of these structures reveal that their plasmonic resonances are strongly influenced by non-local and quantum effects, which push their resonant frequency into the NIR (2.2 um), almost double the frequency of previous experimental works. The confinement factors of these resonators, meanwhile, reach 137 +/- 25, amongst the largest reported in literature for an optical cavity. While our findings indicate that the enhancement of some 'forbidden' transitions are an order of magnitude weaker than predicted, the combined NIR response and large confinement of these structures make them an attractive platform to explore ultra-strongly enhanced spontaneous emission.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Slow control and monitoring system at the JSNS$^{2}$
Authors:
J. S. Park,
S. Ajimura,
M. Botran,
J. H. Choi,
J. W. Choi,
M. K. Cheoun,
T. Dodo,
H. Furuta,
J. Goh,
M. Harada,
S. Hasegawa,
Y. Hino,
T. Hiraiwa,
H. I. Jang,
J. S. Jang,
M. C. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
J. R. Jordan,
D. E Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim
, et al. (37 additional authors not shown)
Abstract:
The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitor…
▽ More
The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage (HV) of the photomultiplier tubes (PMTs), the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in June 2020. In this paper, we present a description of the assembly and installation of the SCMS and its performance.
△ Less
Submitted 7 April, 2021; v1 submitted 4 May, 2020;
originally announced May 2020.
-
Pulsed-laser epitaxy of metallic delafossite PdCrO$_2$ films
Authors:
Jong Mok Ok,
Matthew Brahlek,
Woo Seok Choi,
Kevin M. Roccapriore,
Matthew F. Chisholm,
Soyeun Kim,
Changhee Sohn,
Elizabeth Skoropata,
Sangmoon Yoon,
Jun Sung Kim,
Ho Nyung Lee
Abstract:
Alternate stacking of a highly conducting metallic layer with a magnetic triangular layer found in delafossite PdCrO2 provides an excellent platform for discovering intriguing correlated quantum phenomena. Thin film growth of the material may enable not only tuning the basic physical properties beyond what bulk materials can exhibit, but also develo** novel hybrid materials by interfacing with d…
▽ More
Alternate stacking of a highly conducting metallic layer with a magnetic triangular layer found in delafossite PdCrO2 provides an excellent platform for discovering intriguing correlated quantum phenomena. Thin film growth of the material may enable not only tuning the basic physical properties beyond what bulk materials can exhibit, but also develo** novel hybrid materials by interfacing with dissimilar materials, yet this has proven to be extremely challenging. Here, we report the epitaxial growth of metallic delafossite PdCrO2 films by pulsed laser epitaxy (PLE). The fundamental role of the PLE growth conditions, epitaxial strain, and chemical and structural characteristics of the substrate is investigated by growing under various growth conditions and on various types of substrates. While strain plays a large role in improving the crystallinities, the direct growth of epitaxial PdCrO2 films without impurity phases was not successful. We attribute this difficulty to both the chemical and structural dissimilarities between the substrates and volatile nature of PdO layer, which make nucleation of the right phase difficult. This difficulty was overcome by growing CuCrO2 buffer layers before PdCrO2 were grown. Unlike PdCrO2, CuCrO2 films were rather readily grown with a relatively wide growth window. Only monolayer thick buffer layer was sufficient to grow the correct PdCrO2 phase. This result indicates that the epitaxy of Pd-based delafossites is extremely sensitive to the chemistry and structure of the interface, necessitating near perfect substrate materials. The resulting films are commensurately strained and show an antiferromagnetic transition at 40 K that persists down to as thin as 3.6 nm in thickness.
△ Less
Submitted 20 February, 2020; v1 submitted 19 February, 2020;
originally announced February 2020.
-
Evidence of itinerant holes for long-range magnetic order in tungsten diselenide semiconductor with vanadium dopants
Authors:
Bumsub Song,
Seok Joon Yun,
**bao Jiang,
Kory Beach,
Wooseon Choi,
Young-Min Kim,
Humberto Terrones,
Young Jae Song,
Dinh Loc Duong,
Young Hee Lee
Abstract:
One primary concern in diluted magnetic semiconductors (DMSs) is how to establish a long-range magnetic order with a low magnetic do** concentration to maintain the gate tunability of the host semiconductor, as well as to increase Curie temperature. Two-dimensional van der Waals semiconductors have been recently investigated to demonstrate the magnetic order in DMSs; however, a comprehensive und…
▽ More
One primary concern in diluted magnetic semiconductors (DMSs) is how to establish a long-range magnetic order with a low magnetic do** concentration to maintain the gate tunability of the host semiconductor, as well as to increase Curie temperature. Two-dimensional van der Waals semiconductors have been recently investigated to demonstrate the magnetic order in DMSs; however, a comprehensive understanding of the mechanism responsible for the gate-tunable long-range magnetic order in DMSs has not been achieved yet. Here, we introduce a monolayer tungsten diselenide (WSe2) semiconductor with V dopants to demonstrate the long-range magnetic order through itinerant spin-polarized holes. The V atoms are sparsely located in the host lattice by substituting W atoms, which is confirmed by scanning tunneling microscopy and high-resolution transmission electron microscopy. The V impurity states and the valence band edge states are overlapped, which is congruent with density functional theory calculations. The field-effect transistor characteristics reveal the itinerant holes within the hybridized band; this clearly resembles the Zener model. Our study gives an insight into the mechanism of the long-range magnetic order in V-doped WSe2, which can also be used for other magnetically doped semiconducting transition metal dichalcogenides.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
Suppression of Penning discharges between the KATRIN spectrometers
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (129 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space b…
▽ More
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.
△ Less
Submitted 17 September, 2020; v1 submitted 21 November, 2019;
originally announced November 2019.
-
Laser scanning reflection-matrix microscopy for label-free in vivo imaging of a mouse brain through an intact skull
Authors:
Seokchan Yoon,
Hojun Lee,
** Hee Hong,
Yong-Sik Lim,
Wonshik Choi
Abstract:
We present a laser scanning reflection-matrix microscopy combining the scanning of laser focus and the wide-field map** of the electric field of the backscattered waves for eliminating higher-order aberrations even in the presence of strong multiple light scattering noise. Unlike conventional confocal laser scanning microscopy, we record the amplitude and phase maps of reflected waves from the s…
▽ More
We present a laser scanning reflection-matrix microscopy combining the scanning of laser focus and the wide-field map** of the electric field of the backscattered waves for eliminating higher-order aberrations even in the presence of strong multiple light scattering noise. Unlike conventional confocal laser scanning microscopy, we record the amplitude and phase maps of reflected waves from the sample not only at the confocal pinhole, but also at other non-confocal points. These additional measurements lead us to constructing a time-resolved reflection matrix, with which the sample-induced aberrations for the illumination and detection pathways are separately identified and corrected. We realized in vivo reflectance imaging of myelinated axons through an intact skull of a living mouse with the spatial resolution close to the ideal diffraction limit. Furthermore, we demonstrated near-diffraction-limited multiphoton imaging through an intact skull by physically correcting the aberrations identified from the reflection matrix. The proposed method is expected to extend the range of applications, where the knowledge of the detailed microscopic information deep within biological tissues is critical.
△ Less
Submitted 8 October, 2019;
originally announced October 2019.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
Microscopic imaging of non-repetitive dynamic scenes at 5 THz frame rates by time and spatial frequency multiplexing
Authors:
Jungho Moon,
Seok-Chan Yoon,
Yong-sik Lim,
Wonshik Choi
Abstract:
Femtosecond-scale ultrafast imaging is an essential tool for visualizing ultrafast dynamics in molecular biology, physical chemistry, atomic physics, and fluid dynamics. Pump-probe imaging and a streak camera are the most widely used techniques, but they are either demanding the repetitions of the same scene or sacrificing the number of imaging dimensions. Many interesting single-shot ultrafast im…
▽ More
Femtosecond-scale ultrafast imaging is an essential tool for visualizing ultrafast dynamics in molecular biology, physical chemistry, atomic physics, and fluid dynamics. Pump-probe imaging and a streak camera are the most widely used techniques, but they are either demanding the repetitions of the same scene or sacrificing the number of imaging dimensions. Many interesting single-shot ultrafast imaging techniques have been developed in recent years for recording non-repetitive dynamic scenes. Nevertheless, there are still weaknesses in the number of frames, the number of image pixels, or spatial/temporal resolution. Here, we present a single-shot ultrafast microscopy that can capture more than a dozen frames at a time with the frame rate of 5 THz. We combine a spatial light modulator and a custom-made echelon for efficiently generating a large number of reference pulses with designed time delays and propagation angles. The single-shot recording of the interference image between these reference pulses with a sample pulse allows us to retrieve the stroboscopic images of the dynamic scene at the timing of the reference pulses. We demonstrated the recording of 14 temporal snapshots at a time, which is the largest to date, with the optimal temporal resolution set by the laser output pulse. Our ultrafast microscopy is highly scalable in the number of frames and temporal resolutions, and this will have profound impacts on uncovering the interesting spatio-temporal dynamics yet to be explored.
△ Less
Submitted 1 September, 2019;
originally announced September 2019.
-
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards
, et al. (102 additional authors not shown)
Abstract:
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstr…
▽ More
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
△ Less
Submitted 18 March, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
Near-field imaging beyond the probe aperture limit
Authors:
Eunsung Seo,
Young-Ho **,
Wonjun Choi,
Yonghyeon Jo,
Suyeon Lee,
Kyung-Deok Song,
Joonmo Ahn,
Q-Han Park,
Myung-Ki Kim,
Wonshik Choi
Abstract:
Near-field scanning optical microscopy has been an indispensable tool for designing, characterizing and understanding the functionalities of diverse nanoscale photonic devices. As the advances in fabrication technology have driven the devices smaller and smaller, the demand has grown steadily for improving its resolving power, which is determined mainly by the size of the probe attached to the sca…
▽ More
Near-field scanning optical microscopy has been an indispensable tool for designing, characterizing and understanding the functionalities of diverse nanoscale photonic devices. As the advances in fabrication technology have driven the devices smaller and smaller, the demand has grown steadily for improving its resolving power, which is determined mainly by the size of the probe attached to the scanner. The use of a smaller probe has been a straightforward approach to increase the resolving power, but it cannot be made arbitrarily small in practice due to the steep reduction of the collection efficiency. Here, we develop a method to enhance the resolving power of near-field imaging beyond the limit set by the physical size of the probe aperture. The main working principle is to unveil high-order near-field eigenmodes invisible with conventional near-field microscopy. The destructive interference of near-field waves is induced in these high-order eigenmodes by the locally varying phases, which can reveal subaperture-scale fine structural details. To extract these eigenmodes, we construct a self-interference near-field microscopy system and measure a fully phase-referenced far- to near-field transmission matrix (FNTM) composed of near-field amplitude and phase maps recorded for various angles of far-field illumination. By the singular value decomposition of the measured FNTM, we could extract the antisymmetric mode, quadrupole mode, and other higher-order modes hidden under the lowest-order symmetric mode. This enables us to resolve double and triple nano-slots whose gap size (50 nm) is three times smaller than the diameter of the probe aperture (150 nm). The subaperture near-field mode map** by the FTNM can be potentially combined with various existing near-field imaging modalities and promote their ability to interrogate local near-field optical waves of nanoscale devices.
△ Less
Submitted 5 March, 2019;
originally announced March 2019.
-
Gamma-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (101 additional authors not shown)
Abstract:
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test th…
▽ More
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.
△ Less
Submitted 10 July, 2019; v1 submitted 1 March, 2019;
originally announced March 2019.
-
Highly durable crack sensor integrated with silicone rubber cantilever for measuring cardiac contractility in culture media
Authors:
Dong-Su Kim,
Yong Whan Choi,
Yun-** Jeong,
Jongsung Park,
Nomin-Erdene Oyunbaatar,
Eung-Sam Kim,
Mansoo Choi,
Dong-Weon Lee
Abstract:
We propose a novel cantilever device integrated with a polydimethylsiloxane (PDMS)-encapsulated crack sensor that directly measures the cardiac contractility. The crack sensor was chemically bonded to a PDMS thin layer to form a sandwiched structure which allows to be operated very stably in culture media. The reliability of the proposed crack sensor has improved dramatically compared to no encaps…
▽ More
We propose a novel cantilever device integrated with a polydimethylsiloxane (PDMS)-encapsulated crack sensor that directly measures the cardiac contractility. The crack sensor was chemically bonded to a PDMS thin layer to form a sandwiched structure which allows to be operated very stably in culture media. The reliability of the proposed crack sensor has improved dramatically compared to no encapsulation layer. After evaluating the durability of the crack sensor bonded with the PDMS layer, cardiomyocytes were cultured on the nano-patterned cantilever for real-time measurement of cardiac contractile forces. The highly sensitive crack sensor continuously measured the cardiac contractility without changing its gauge factor for up to 26 days (>5 million heartbeats). In addition, changes in contractile force induced by drugs were monitored using the crack sensor-integrated cantilever. Finally, experimental results were compared with those obtained via conventional electrophysiological methods to verify the feasibility of building a contraction-based drug-toxicity testing system.
△ Less
Submitted 8 February, 2019;
originally announced February 2019.
-
Lattice-mismatched semiconductor heterostructures
Authors:
Dong Liu,
Sang June Cho,
Jung-Hun Seo,
Kwangeun Kim,
Munho Kim,
Jian Shi,
Xin Yin,
Wonsik Choi,
Chen Zhang,
Jisoo Kim,
Mohadeseh A. Baboli,
Jeongpil Park,
Jihye Bong,
In-Kyu Lee,
Jiarui Gong,
Solomon Mikael,
Jae Ha Ryu,
Parsian K. Mohseni,
Xiuling Li,
Shaoqin Gong,
Xudong Wang,
Zhenqiang Ma
Abstract:
Semiconductor heterostructure is a critical building block for modern semiconductor devices. However, forming semiconductor heterostructures of lattice-mismatch has been a great challenge for several decades. Epitaxial growth is infeasible to form abrupt heterostructures with large lattice-mismatch while mechanical-thermal bonding results in a high density of interface defects and therefore severe…
▽ More
Semiconductor heterostructure is a critical building block for modern semiconductor devices. However, forming semiconductor heterostructures of lattice-mismatch has been a great challenge for several decades. Epitaxial growth is infeasible to form abrupt heterostructures with large lattice-mismatch while mechanical-thermal bonding results in a high density of interface defects and therefore severely limits device applications. Here we show an ultra-thin oxide-interfaced approach for the successful formation of lattice-mismatched semiconductor heterostructures. Following the depiction of a theory on the role of interface oxide in forming the heterostructures, we describe experimental demonstrations of Ge/Si (diamond lattices), Si/GaAs (zinc blende lattice), GaAs/GaN (hexagon lattice), and Si/GaN heterostructures. Extraordinary electrical performances in terms of ideality factor, current on/off ratio, and reverse breakdown voltage are measured from p-n diodes fabricated from the four types of heterostructures, significantly outperforming diodes derived from other methods. Our demonstrations indicate the versatility of the ultra-thin-oxide-interface approach in forming lattice-mismatched heterostructures, open up a much larger possibility for material combinations for heterostructures, and pave the way toward broader applications in electronic and optoelectronic realms.
△ Less
Submitted 25 December, 2018;
originally announced December 2018.
-
Simultaneous iterative learning control of mode entrainment and error field
Authors:
Wilkie Choi,
Francesco Volpe
Abstract:
It is shown that static error fields (EFs) can severely limit the maximum rotation frequency achievable in mode entrainment by applied rotating fields. It is also shown that the rotation non-uniformities caused by an EF can be used to diagnose and correct said EF in real time. Simulations using typical DIII-D data show that this can be achieved within a small number of mode rotation periods by an…
▽ More
It is shown that static error fields (EFs) can severely limit the maximum rotation frequency achievable in mode entrainment by applied rotating fields. It is also shown that the rotation non-uniformities caused by an EF can be used to diagnose and correct said EF in real time. Simulations using typical DIII-D data show that this can be achieved within a small number of mode rotation periods by an iterative learning control algorithm. In addition to rapidly correcting the EF, this gives access to high entrainment frequencies that would not be accessible otherwise, and paves the way to rotational stabilization and improved mode control.
△ Less
Submitted 12 December, 2018;
originally announced December 2018.
-
Ferroelectric polarization rotation in order-disorder-type LiNbO3 thin films
Authors:
Tae Sup Yoo,
Sang A Lee,
Changjae Roh,
Seunghun Kang,
Daehee Seol,
Xinwei Guan,
Jong-Seong Bae,
Jiwoong Kim,
Young-Min Kim,
Hu Young Jeong,
Seunggyo Jeong,
Ahmed Yousef Mohamed,
Deok-Yong Cho,
Ji Young Jo,
Sungkyun Park,
Tom Wu,
Yunseok Kim,
Jongseok Lee,
Woo Seok Choi
Abstract:
The direction of ferroelectric polarization is prescribed by the symmetry of the crystal structure. Therefore, rotation of the polarization direction is largely limited, despite the opportunity it offers in understanding important dielectric phenomena such as piezoelectric response near the morphotropic phase boundaries and practical applications such as ferroelectric memory. In this study, we rep…
▽ More
The direction of ferroelectric polarization is prescribed by the symmetry of the crystal structure. Therefore, rotation of the polarization direction is largely limited, despite the opportunity it offers in understanding important dielectric phenomena such as piezoelectric response near the morphotropic phase boundaries and practical applications such as ferroelectric memory. In this study, we report the observation of continuous rotation of ferroelectric polarization in order-disorder type LiNbO3 thin films. The spontaneous polarization could be tilted from an out-of-plane to an in-plane direction in the thin film by controlling the Li vacancy concentration within the hexagonal lattice framework. Partial inclusion of monoclinic-like phase is attributed to the breaking of macroscopic inversion symmetry along different directions and the emergence of ferroelectric polarization along the in-plane direction.
△ Less
Submitted 7 December, 2018;
originally announced December 2018.
-
Coherent space-gated microscopy: a step towards deep-tissue phase imaging of biological cells
Authors:
Mooseok Jang,
Hakseok Ko,
Won Kyu Lee,
Jae-Seung Lee,
Wonshik Choi
Abstract:
High-resolution optical microscopy suffers from a low contrast in scattering media where a multiply scattered wave obscures a ballistic wave used for image formation. To extend the imaging depth, various gating operations - confocal, coherence, and polarization gating - have been devised to filter out the multiply scattered wave. However, these gating methods are imperfect as they all act on the d…
▽ More
High-resolution optical microscopy suffers from a low contrast in scattering media where a multiply scattered wave obscures a ballistic wave used for image formation. To extend the imaging depth, various gating operations - confocal, coherence, and polarization gating - have been devised to filter out the multiply scattered wave. However, these gating methods are imperfect as they all act on the detection plane located outside a scattering medium. Here, we present a new gating scheme, called 'space' gating, that rejects the multiply scattered wave directly at the object plane inside a scattering medium. Specifically, we introduced a 30 $μ$m-wide acoustic focus to the object plane and reconstructed a coherent image only with the ballistic wave modulated by acousto-optic interaction. This method allows us to reject the multiply scattered wave that the existing gating methods cannot filter out and improves the ratio of the ballistic wave to the multiply scattered wave by more than 100 times for a scattering medium more than 20 times thicker than its scattering mean free path. Using the coherent imaging technique based on space gating, we demonstrate the unprecedented imaging capability - phase imaging of optically transparent biological cells fully embedded within a scattering medium - with a spatial resolution of 1.5 $μ$m.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
The COSINE-100 Data Acquisition System
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. S. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim
, et al. (23 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital co…
▽ More
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
△ Less
Submitted 26 June, 2018;
originally announced June 2018.
-
The KATRIN Superconducting Magnets: Overview and First Performance Results
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (99 additional authors not shown)
Abstract:
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet sy…
▽ More
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pum** sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
△ Less
Submitted 22 June, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Muon-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel
, et al. (109 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of part…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.
△ Less
Submitted 13 December, 2018; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
Authors:
KATRIN Collaboration,
M. Arenz,
W. -J. Baek,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
R. Berendes,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
W. Buglak,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (105 additional authors not shown)
Abstract:
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such…
▽ More
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
△ Less
Submitted 3 May, 2018;
originally announced May 2018.
-
Background model for the NaI(Tl) crystals in COSINE-100
Authors:
P. Adhikari,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
W. S. Kang,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim
, et al. (24 additional authors not shown)
Abstract:
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmog…
▽ More
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The dominant contributors in this energy region are found to be $^{210}$Pb and $^3$H.
△ Less
Submitted 11 June, 2018; v1 submitted 14 April, 2018;
originally announced April 2018.
-
Polar Solvent Vapour Induced Photo-Physical Properties on the Solid-State Organometallic Halide Perovskite Nanocrystals
Authors:
Sang-Hyun Chin,
** Woo Choi,
Hee Chul Woo,
Jong H. Kim,
Hong Seok Lee,
Chang-Lyoul Lee
Abstract:
The optoelectric applications, light emitters and photovoltaics, with organometallic halide perovskite materials have been decided by dynamics of charge carriers in grains on the polycrystalline thin films. Especially, polar solvent vapour recrystallizes perovskites and changes their grain sizes. In this paper, various polar solvents were evaluated with density functional theory calculation. And a…
▽ More
The optoelectric applications, light emitters and photovoltaics, with organometallic halide perovskite materials have been decided by dynamics of charge carriers in grains on the polycrystalline thin films. Especially, polar solvent vapour recrystallizes perovskites and changes their grain sizes. In this paper, various polar solvents were evaluated with density functional theory calculation. And a stociometric treatment with these solvents which enhanced photoluminescence intensity was established. The properties of solvents which caused dramatic photoluminescence enhancement and quantum confinement effect were discussed.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.