-
Intra-instrument channel workable, optical- resolution photoacoustic and ultrasonic mini-probe system for clinical gastrointestinal endoscopy
Authors:
Minjae Kim,
Kang Won Lee,
KiSik Kim,
Oleksandra Gulenko,
Cheol Lee,
Bora Keum,
Hoon Jai Chun,
Hyuk Soon Choi,
Chae Un Kim,
Joon-Mo Yang
Abstract:
There has been a longstanding expectation that the optical resolution embodiment of photoacoustic tomography could have a substantial impact on gastrointestinal endoscopy by enabling microscopic visualization of the vasculature based on the endogenous contrast mechanism. Although multiple studies have demonstrated the in vivo imaging capability of a developed imaging device over the last decade, t…
▽ More
There has been a longstanding expectation that the optical resolution embodiment of photoacoustic tomography could have a substantial impact on gastrointestinal endoscopy by enabling microscopic visualization of the vasculature based on the endogenous contrast mechanism. Although multiple studies have demonstrated the in vivo imaging capability of a developed imaging device over the last decade, the implementation of such an endoscopic system that can be applied immediately when necessary via the instrument channel of a video endoscope has been a challenge. In this study, we developed a 3.38 mm diameter catheter based, integrated optical resolution photoacoustic and ultrasonic miniprobe system and successfully demonstrated its intrainstrument channel workability for the standard 3.7 mm diameter instrument channel of a clinical video endoscope based on a swine model. Through the instrument channel, we acquired the first in vivo photoacoustic and ultrasonic dual mode endoscopic images from the esophagogastric junction, which is one of the most frequently cited anatomical sites in the gastrointestinal tract in relation to Barretts esophagus. Moreover, from a rat colorectum in vivo imaging experiment, we visualized hierarchically developed mesh like capillary networks with a hole size as small as 50 microns, which suggests the potential level of image details that could be photoacoustically provided in clinical settings in the future.
△ Less
Submitted 18 October, 2021;
originally announced October 2021.
-
Data Acquisition System for the UFFO Pathfinder
Authors:
G. W. Na,
K. -B. Ahn,
H. S. Choi,
Y. J. Choi,
B. Grossan,
I. Hermann,
S. Jeong,
A. Jung,
J. E. Kim,
S. -W. Kim,
Y. W. Kim,
J. Lee,
H. Lim,
E. V. Linder,
K. W. Min,
J. W. Nam,
K. H. Nam,
M. I. Panasyuk,
I. H. Park,
G. F. Smoot,
Y. D. Suh,
S. Svertilov,
N. Vedenkin,
I. Yashin,
M. H. Zhao
Abstract:
The Ultra-Fast Flash Observatory (UFFO) Pathfinder is a payload on the Russian Lomonosov satellite, scheduled to be launched in November 2011. The Observatory is designed to detect early UV/Optical photons from Gamma-Ray Bursts (GRBs). There are two telescopes and one main data acquisition system: the UFFO Burst Alert & Trigger Telescope (UBAT), the Slewing Mirror Telescope (SMT), and the UFFO Dat…
▽ More
The Ultra-Fast Flash Observatory (UFFO) Pathfinder is a payload on the Russian Lomonosov satellite, scheduled to be launched in November 2011. The Observatory is designed to detect early UV/Optical photons from Gamma-Ray Bursts (GRBs). There are two telescopes and one main data acquisition system: the UFFO Burst Alert & Trigger Telescope (UBAT), the Slewing Mirror Telescope (SMT), and the UFFO Data Acquisition (UDAQ) system. The UDAQ controls and manages the operation and communication of each telescope, and is also in charge of the interface with the satellite. It will write the data taken by each telescope to the NOR flash memory and sends them to the satellite via the Bus-Interface system (BI). It also receives data from the satellite including the coordinates and time of an external trigger from another payload, and distributes them to two telescopes. These functions are implemented in field programmable gates arrays (FPGA) for low power consumption and fast processing without a microprocessor. The UDAQ architecture, control of the system, and data flow will be presented.
△ Less
Submitted 28 June, 2011; v1 submitted 20 June, 2011;
originally announced June 2011.
-
Implementation of the readout system in the UFFO Slewing Mirror Telescope
Authors:
J. E. Kim,
H. Lim,
A. Jung,
K. -B Ahn,
H. S. Choi,
Y. J. Choi,
B. Grossan,
I. Hermann,
S. Jeong,
S. -W. Kim,
Y. W. Kim,
J. Lee,
E. V. Linder,
K. W. Min,
G. W. Na,
J. W. Nam,
K. H. Nam,
M. I. Panayuk,
I. H. Park,
G. F. Smoot,
Y. D. Suh,
S. Svelitov,
N. Vedenken,
I. Yashin,
M. H. Zhao
Abstract:
The Ultra-Fast Flash Observatory (UFFO) is a new space-based experiment to observe Gamma-Ray Bursts (GRBs). GRBs are the most luminous electromagnetic events in the universe and occur randomly in any direction. Therefore the UFFO consists of two telescopes; UFFO Burst Alert & Trigger Telescope (UBAT) to detect GRBs using a wide field-of-view (FOV), and a Slewing Mirror Telescope (SMT) to observe U…
▽ More
The Ultra-Fast Flash Observatory (UFFO) is a new space-based experiment to observe Gamma-Ray Bursts (GRBs). GRBs are the most luminous electromagnetic events in the universe and occur randomly in any direction. Therefore the UFFO consists of two telescopes; UFFO Burst Alert & Trigger Telescope (UBAT) to detect GRBs using a wide field-of-view (FOV), and a Slewing Mirror Telescope (SMT) to observe UV/optical events rapidly within the narrow, targeted FOV. The SMT is a Ritchey-Chretien telescope that uses a motorized mirror system and an Intensified Charge-Coupled Device (ICCD). When the GRB is triggered by the UBAT, the SMT receives the position information and rapidly tilts the mirror to the target. The ICCD start to take the data within a second after GRB is triggered. Here we give the details about the SMT readout electronics that deliver the data.
△ Less
Submitted 20 June, 2011;
originally announced June 2011.