First results of AUP Nb3Sn quadrupole horizontal tests
Authors:
M. Baldini,
G. Ambrosio,
G. Apollinari,
J. Blowers,
R. Bossert,
R. Carcagno,
G. Chlachidze,
J. DiMarco,
S. Feher,
S. Krave,
V. Lombardo,
L. Martin,
C. Narug,
T. H. Nicol,
V. Nikolic,
A. Nobrega,
V. Marinozzi,
C. Orozco,
T. Page,
S. Stoynev,
T. Strauss,
M. Turenne,
D. Turrioni,
A. Vouris,
M. Yu
, et al. (26 additional authors not shown)
Abstract:
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a…
▽ More
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a CERN project with a world-wide collaboration. It is under construction and utilizes Nb3Sn Magnets (named MQXF) as key ingredients to increase tenfold the integrated luminosity delivered to the CMS and ATLAS experiments in the next decade.
The HL-LHC AUP is the US effort to contribute approximately 50% of the low-beta focusing magnets and crab cavities for the HL-LHC.
This paper will present the program to fabricate the Nb3Sn superconducting magnets. We are reporting the status of the HL-LHC AUP project present the results from horizontal tests of the first fully assembled cryo-assembly.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Quench Performance of the First Pre-series AUP Cryo-assembly
Authors:
M. Baldini,
G. Chlachidze,
G. Apollinari,
J. Dimarco,
S. Feher,
V. Nikolic,
D. Orris,
R. Rabehl,
S. Stoynev,
T. Strauss,
M. Tartaglia,
A. Vouris
Abstract:
The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include eight cryo-assemblies that are expected to be fabricated and delivered to CERN by the US HL-LHC Accelerator Upgrade Project (AUP) as part of the U.S. contributions to the HL-LHC. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 and Q3 inner triplet optical elements in front of th…
▽ More
The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include eight cryo-assemblies that are expected to be fabricated and delivered to CERN by the US HL-LHC Accelerator Upgrade Project (AUP) as part of the U.S. contributions to the HL-LHC. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 and Q3 inner triplet optical elements in front of the two interaction points. Each cryo-assembly consists of two 4.2 m long Nb3Sn quadrupole magnets with aperture 150 mm and operating gradient 132.6 T/m. The first pre-series cryo-assembly has been fabricated and successfully tested at the horizontal test facility at Fermi National Accelerator Laboratory. In this manuscript we report the quench test results of the LQXFA/B-01 cryo-assembly. The primary objective of the horizontal test is full cryo-assembly qualification and validation of the performance requirements.
△ Less
Submitted 29 February, 2024;
originally announced March 2024.
-
Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at Fermilab
Authors:
J. DiMarco,
P. Akella,
G. Ambrosio,
M. Baldini,
G. Chlachidze,
S. Feher,
J. Nogiec,
V. Nikolic,
S. Stoynev,
T. Strauss,
M. Tartaglia,
P. Thompson,
D. Walbridge
Abstract:
MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the US Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specific…
▽ More
MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the US Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis position, and for magnet variations in positioning and local field profile. This paper describes the results of the magnetic and alignment measurements which characterize the first LQXFA/B assembly.
△ Less
Submitted 13 December, 2023;
originally announced December 2023.
-
Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
G. Arnau Izquierdo,
M. Baldini,
A. Ballarino,
C. Barth,
A. Ben Yahia,
J. Blowers,
P. Borges De Sousa,
R. Bossert,
B. Bulat,
R. Carcagno,
D. W. Cheng,
G. Chlachidze,
L. Cooley,
M. Crouvizier,
A. Devred,
J. DiMarco,
S. Feher,
P. Ferracin,
J. Ferradas Troitino,
L. Garcia Fajardo,
S. Gourlay
, et al. (33 additional authors not shown)
Abstract:
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of th…
▽ More
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
A Strategic Approach to Advance Magnet Technology for Next Generation Colliders
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
D. Arbelaez,
B. Auchmann,
S. Balachandran,
M. Baldini,
A. Ballarino,
S. Barua,
E. Barzi,
A. Baskys,
C. Bird,
J. Boerme,
E. Bosque,
L. Brouwer,
S. Caspi,
N. Cheggour,
G. Chlachidze,
L. Cooley,
D. Davis,
D. Dietderich,
J. DiMarco,
L. English,
L. Garcia Fajardo
, et al. (52 additional authors not shown)
Abstract:
Colliders are built on a foundation of superconducting magnet technology that provides strong dipole magnets to maintain the beam orbit and strong focusing magnets to enable the extraordinary luminosity required to probe physics at the energy frontier. The dipole magnet strength plays a critical role in dictating the energy reach of a collider, and the superconducting magnets are arguably the domi…
▽ More
Colliders are built on a foundation of superconducting magnet technology that provides strong dipole magnets to maintain the beam orbit and strong focusing magnets to enable the extraordinary luminosity required to probe physics at the energy frontier. The dipole magnet strength plays a critical role in dictating the energy reach of a collider, and the superconducting magnets are arguably the dominant cost driver for future collider facilities. As the community considers opportunities to explore new energy frontiers, the importance of advanced magnet technology - both in terms of magnet performance and in the magnet technology's potential for cost reduction - is evident, as the technology status is essential for informed decisions on targets for physics reach and facility feasibility.
△ Less
Submitted 26 March, 2022;
originally announced March 2022.
-
MQXFA Final Design Report
Authors:
Giorgio Ambrosio,
Kathleen Amm,
Mike Anerella,
Giorgio Apollinari,
Maria Baldini,
Anis Ben Yahia,
James Blowers,
Ruben Carcagno,
Daniel Cheng,
Guram Chlachidze,
Lance Cooley,
Sandor Feher,
Paolo Ferracin,
Henry Hocker,
Susana Izquierdo Bermudez,
Piyush Joshi,
Vito Lombardo,
Vittorio Marinozzi,
Joseph Muratore,
Michael Naus,
Fred Nobrega,
Heng Pan,
Marcellus Parker,
Ian Pong,
Soren Prestemon
, et al. (7 additional authors not shown)
Abstract:
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, man…
▽ More
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.
*Supported by the U.S. Department of Energy, Office of Science, Office of High Energy Physics
△ Less
Submitted 13 March, 2022;
originally announced March 2022.
-
MDPCT1 quench data and performance analysis
Authors:
Stoyan Emilov Stoynev,
Maria Baldini,
Emanuela Z. Barzi,
Gouram Chlachidze,
Vadim V. Kashikhin,
Steven T. Krave,
Igor Novitski,
Daniele Turrioni,
Alexander V. Zlobin
Abstract:
MDPCT1 is a four-layer cos-theta Nb3Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T…
▽ More
MDPCT1 is a four-layer cos-theta Nb3Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T and no evidence of degradation, the outer coils degraded over the course of testing. By adopting new measurement and analysis techniques at FNAL we are discussing in detail what happened. Both success and failure in our diagnostics are discussed. The evolution of techniques over the course of two tests (and three thermal cycles) shows the path to address challenges brought by the first four-layer magnet tested at FNAL. This paper presents the analysis of quench data along with diagnostic features and complementary measurements taken in support of the magnet performance analysis.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Designing a Magnetic Measurement Data Acquisition and Control System with Reuse in Mind: A Rotating Coil System Example
Authors:
J. M. Nogiec,
P. Akella,
G. Chlachidze,
J. DiMarco,
M. Tartaglia,
P. Thompson,
K. Trombly-Freytag,
D. Walbridge
Abstract:
Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for so…
▽ More
Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab
Authors:
J. DiMarco,
P. Akella,
G. Ambrosio,
D. Assell,
M. Baldini,
G. Chlachidze,
S. Feher,
J. Nogiec,
V. Nikolic,
S. Stoynev,
T. Strauss,
M. Tartaglia,
P. Thompson,
D. Walbridge,
W. Ghiorso,
X. Wang
Abstract:
LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test faci…
▽ More
LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profile. A multi-probe, PCB-based rotating coil and Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. This paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab
Authors:
A. Galt,
O. Al Atassi,
G. Chlachidze,
T. Cummings,
S. Feher,
A. Hocker,
S. Kotelnikov,
M. Lamm,
A. Makulski,
J. Nogiec,
D. Orris,
R. Pilipenko,
M. Tartaglia
Abstract:
A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, t…
▽ More
A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, the quench controls and data management system. The Tier-I and Tier-II are completely independent and fully redundant systems. The Tier-3 system is based on National Instruments (NI) C-RIO and provides the user interface for quench controls and data management. It is independent from Tiers I & II. The DQD provides both quench detection and quench characterization (monitoring) capability. Both DQD and AQD have built-in high voltage isolation and user programmable gains and attenuations. The DQD and AQD also includes user configured current dependent thresholding and validation times.
A 1st article of the three-tier system was fully implemented on the new Fermilab magnet test stand for the HL-LHC Accelerator Up-grade Project (AUP). It successfully provided quench protection and monitoring (QPM) for a cold superconducting bus test in November 2020. The Mu2e quench detection design has since been implemented for production testing of the AUP magnets. A detailed description of the system along with results from the AUP superconducting bus test will be presented.
△ Less
Submitted 1 December, 2021;
originally announced December 2021.
-
Insertion Magnets
Authors:
G. Ambrosio,
M. Anerella,
R. Bossert,
D. Cheng,
G. Chlachidze,
D. Dietderich,
D Duarte Ramos,
P. Fabbricatore,
S. Farinon,
H. Felice,
P. Ferracin,
P. Fessia,
J. Garcia Matos,
A. Ghosh,
P. Hagen,
S. Izquierdo Bermudez,
M. Juchno,
S. Krave,
M. Marchevsky,
T. Nakamoto,
T. Ogitsu,
J. C. Perez,
H. Prin,
J. M. Rifflet,
G. L. Sabbi
, et al. (12 additional authors not shown)
Abstract:
Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temper…
▽ More
Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.
△ Less
Submitted 26 May, 2017;
originally announced May 2017.
-
Experimental results and analysis from the 11 T Nb3Sn DS dipole
Authors:
G. Chlachidze,
I. Novitski,
A. V. Zlobin,
B. Auchmann,
M. Karppinen
Abstract:
FNAL and CERN are develo** a 5.5-m-long twin-aperture Nb3Sn dipole suitable for installation in the LHC. A 2-m-long single-aperture demonstrator dipole with 60 mm bore, a nominal field of 11 T at the LHC nominal current of 11.85 kA and 20% margin has been developed and tested. This paper presents the results of quench protection analysis and protection heater study for the Nb3Sn demonstrator dip…
▽ More
FNAL and CERN are develo** a 5.5-m-long twin-aperture Nb3Sn dipole suitable for installation in the LHC. A 2-m-long single-aperture demonstrator dipole with 60 mm bore, a nominal field of 11 T at the LHC nominal current of 11.85 kA and 20% margin has been developed and tested. This paper presents the results of quench protection analysis and protection heater study for the Nb3Sn demonstrator dipole. Extrapolations of the results for long magnet and operation in LHC are also presented.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.
-
Modeling heat transfer from quench protection heaters to superconducting cables in Nb3Sn magnets
Authors:
T. Salmi,
D. Arbelaez,
S. Caspi,
H. Felice,
S. Prestemon,
G. Chlachidze,
H. H. J. ten Kate
Abstract:
We use a recently developed quench protection heater modeling tool for an analysis of heater delays in superconducting high-field Nb3Sn accelerator magnets. The results suggest that the calculated delays are consistent with experimental data, and show how the heater delay depends on the main heater design parameters.
We use a recently developed quench protection heater modeling tool for an analysis of heater delays in superconducting high-field Nb3Sn accelerator magnets. The results suggest that the calculated delays are consistent with experimental data, and show how the heater delay depends on the main heater design parameters.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.