-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and develo** detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Conceptual design of the Spin Physics Detector
Authors:
V. M. Abazov,
V. Abramov,
L. G. Afanasyev,
R. R. Akhunzyanov,
A. V. Akindinov,
N. Akopov,
I. G. Alekseev,
A. M. Aleshko,
V. Yu. Alexakhin,
G. D. Alexeev,
M. Alexeev,
A. Amoroso,
I. V. Anikin,
V. F. Andreev,
V. A. Anosov,
A. B. Arbuzov,
N. I. Azorskiy,
A. A. Baldin,
V. V. Balandina,
E. G. Baldina,
M. Yu. Barabanov,
S. G. Barsov,
V. A. Baskov,
A. N. Beloborodov,
I. N. Belov
, et al. (270 additional authors not shown)
Abstract:
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarize…
▽ More
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarized beams at JINR.
The main objective of the proposed experiment is the comprehensive study of the unpolarized and polarized gluon content of the nucleon. Spin measurements at the Spin Physics Detector at the NICA collider have bright perspectives to make a unique contribution and challenge our understanding of the spin structure of the nucleon. In this document the Conceptual Design of the Spin Physics Detector is presented.
△ Less
Submitted 2 February, 2022; v1 submitted 31 January, 2021;
originally announced February 2021.
-
MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
L. García Ordóñez,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri
, et al. (7 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also indicated.
△ Less
Submitted 20 July, 2019;
originally announced July 2019.
-
The Hybrid MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buechele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai
, et al. (6 additional authors not shown)
Abstract:
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o…
▽ More
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Maggiora,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri
, et al. (10 additional authors not shown)
Abstract:
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination…
▽ More
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors
Authors:
M. Alexeev,
R Birsa,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fishcher,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
K. Koenigsmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri,
F. A. Pereira
, et al. (10 additional authors not shown)
Abstract:
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are describe…
▽ More
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.
△ Less
Submitted 25 October, 2017;
originally announced October 2017.
-
Novel MPGD based Detectors of Single Photons in COMPASS RICH-1
Authors:
J. Agarwala M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy
, et al. (12 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly dev…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 24 October, 2017;
originally announced October 2017.
-
The COMPASS Setup for Physics with Hadron Beams
Authors:
Ph. Abbon,
C. Adolph,
R. Akhunzyanov,
Yu. Alexandrov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
V. Anosov,
A. Austregesilo,
B. Badelek,
F. Balestra,
J. Barth,
G. Baum,
R. Beck,
Y. Bedfer,
A. Berlin,
J. Bernhard,
K. Bicker,
E. R. Bielert,
J. Bieling,
R. Birsa,
J. Bisplinghoff,
M. Bodlak,
M. Boer
, et al. (207 additional authors not shown)
Abstract:
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well…
▽ More
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.
△ Less
Submitted 7 October, 2014;
originally announced October 2014.
-
Pattern recognition and PID for COMPASS RICH-1
Authors:
P. Abbon,
M. Alexeev,
H. Angerer,
R. Birsa,
P. Bordalo,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
M. L. Colantoni,
T. Dafni,
S. Dalla Torre,
E. Delagnes,
O. Denisov,
H. Deschamps,
V. Diaz,
N. Dibiase,
V. Duic,
W. Eyrich,
A. Ferrero,
M. Finger,
M. Finger Jr,
H. Fischer,
S. Gerassimov,
M. Giorgi
, et al. (44 additional authors not shown)
Abstract:
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure…
▽ More
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure and algorithms, and the detector characterization and PID results.
△ Less
Submitted 3 February, 2009;
originally announced February 2009.