-
Polarity control by inversion domain suppression in N-polar III-nitride heterostructures
Authors:
Hengfang Zhang,
Ingemar Persson,
Jr. -Tai Chen,
Alexis Papamichail,
Dat Q. Tran,
Per O. Å. Persson,
Plamen P. Paskov,
Vanya Darakchieva
Abstract:
Nitrogen-polar III-nitride heterostructures offer advantages over metal-polar structures in high frequency and high power applications. However, polarity control in III-nitrides is difficult to achieve as a result of unintentional polarity inversion domains (IDs). Herein, we present a comprehensive structural investigation with both atomic detail and thermodynamic analysis of the polarity evolutio…
▽ More
Nitrogen-polar III-nitride heterostructures offer advantages over metal-polar structures in high frequency and high power applications. However, polarity control in III-nitrides is difficult to achieve as a result of unintentional polarity inversion domains (IDs). Herein, we present a comprehensive structural investigation with both atomic detail and thermodynamic analysis of the polarity evolution in low- and high-temperature AlN layers on on-axis and 4$^{\circ}$ off-axis Carbon-face 4H-SiC (000$\bar{1}$) grown by hot-wall metal organic chemical vapor deposition. A polarity control strategy has been developed by variation of thermodynamic Al supersaturation and substrate misorientation angle in order to achieve desired growth mode and polarity. We demonstrate that IDs are totally suppressed for high-temperature AlN nucleation layers when step-flow growth mode is achieved at the off-axis. We employ this approach to demonstrate high quality N-polar epitaxial AlGaN/GaN/AlN heterostructures.
△ Less
Submitted 1 December, 2022;
originally announced December 2022.
-
Lifetime-Limited Interrogation of Two Independent ${}^{27}\textrm{Al}^{+}$ Clocks Using Correlation Spectroscopy
Authors:
E. R. Clements,
M. E. Kim,
K. Cui,
A. M. Hankin,
S. M. Brewer,
J. Valencia,
J. -S. Chen,
C. W. Chou,
D. R. Leibrandt,
D. B. Hume
Abstract:
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perfor…
▽ More
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the $^1S_0\leftrightarrow{}^3P_0$ transition in $^{27}$Al$^+$. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of $1.12\times10^{15}$ Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s $^3P_0$ state lifetime and supports a measurement instability of $(1.8\pm0.5)\times 10^{-16}/\sqrt{τ/\textrm{s}}$ for averaging periods longer than the probe duration when deadtime is negligible.
△ Less
Submitted 4 July, 2020;
originally announced July 2020.
-
Efficient sideband cooling protocol for long trapped-ion chains
Authors:
J. -S. Chen,
K. Wright,
N. C. Pisenti,
D. Murphy,
K. M. Beck,
K. Landsman,
J. M. Amini,
Y. Nam
Abstract:
Trapped ions are a promising candidate for large scale quantum computation. Several systems have been built in both academic and industrial settings to implement modestly-sized quantum algorithms. Efficient cooling of the motional degrees of freedom is a key requirement for high-fidelity quantum operations using trapped ions. Here, we present a technique whereby individual ions are used to cool in…
▽ More
Trapped ions are a promising candidate for large scale quantum computation. Several systems have been built in both academic and industrial settings to implement modestly-sized quantum algorithms. Efficient cooling of the motional degrees of freedom is a key requirement for high-fidelity quantum operations using trapped ions. Here, we present a technique whereby individual ions are used to cool individual motional modes in parallel, reducing the time required to bring an ion chain to its motional ground state. We demonstrate this technique experimentally and develop a model to understand the efficiency of our parallel sideband cooling technique compared to more traditional methods. This technique is applicable to any system using resolved sideband cooling of co-trapped atomic species and only requires individual addressing of the trapped particles.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Measurements of $^{27}$Al$^{+}$ and $^{25}$Mg$^{+}$ magnetic constants for improved ion clock accuracy
Authors:
S. M. Brewer,
J. -S. Chen,
K. Beloy,
A. M. Hankin,
E. R. Clements,
C. W. Chou,
W. F. McGrew,
X. Zhang,
R. J. Fasano,
D. Nicolodi,
H. Leopardi,
T. M. Fortier,
S. A. Diddams,
A. D. Ludlow,
D. J. Wineland,
D. R. Leibrandt,
D. B. Hume
Abstract:
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the…
▽ More
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the $^{27}$Al$^{+}$ quantum-logic clock systematic uncertainty. The measurement of $C_{2}$ is in agreement with a previous measurement and a new calculation at the $1~σ$ level. The measurement of $ΔW$ is in good agreement with a recent measurement and differs from a previously published result by approximately $2σ$. With the improved value for $ΔW$, we deduce an improved value for the nuclear-to-electronic g-factor ratio $g_{I}/g_{J} = 9.299 ~308 ~313(60) \times 10^{-5}$ and the nuclear g-factor for the $^{25}$Mg nucleus $g_{I} = 1.861 ~957 ~82(28) \times 10^{-4}$. Using the values of $C_{2}$ and $ΔW$ presented here, we derive a quadratic Zeeman shift of the $^{27}$Al$^{+}$ quantum-logic clock of $Δν/ ν= -(9241.8 \pm 3.7) \times 10^{-19}$, for a bias magnetic field of $B \approx 0.12$~mT.
△ Less
Submitted 22 May, 2019; v1 submitted 11 March, 2019;
originally announced March 2019.
-
Systematic uncertainty due to background-gas collisions in trapped-ion optical clocks
Authors:
A. M. Hankin,
E. R. Clements,
Y. Huang,
S. M. Brewer,
J. -S. Chen,
C. W. Chou,
D. B. Hume,
D. R. Leibrandt
Abstract:
We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-therma…
▽ More
We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order $10^{-16}$ at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the contribution of collisional heating to the spectroscopy signal is highly suppressed and we calculate the BGC shift to be $-0.6(2.4)\times 10^{-19}$, where the shift is due to collisional heating time-dilation and the uncertainty is dominated by the worst case $\pm π/2$ bound used for collisional phase shift of the $^{27}$Al$^+$ superposition state. We experimentally validate the framework and determine the background-gas pressure in situ using measurements of the rate of collisions that cause reordering of mixed-species ion pairs.
△ Less
Submitted 23 July, 2019; v1 submitted 22 February, 2019;
originally announced February 2019.
-
An $^{27}$Al$^{+}$ quantum-logic clock with systematic uncertainty below $10^{-18}$
Authors:
S. M. Brewer,
J. -S. Chen,
A. M. Hankin,
E. R. Clements,
C. W. Chou,
D. J. Wineland,
D. B. Hume,
D. R. Leibrandt
Abstract:
We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvem…
▽ More
We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous $^{27}$Al$^{+}$ clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous $^{27}$Al$^{+}$ clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
△ Less
Submitted 22 May, 2019; v1 submitted 20 February, 2019;
originally announced February 2019.
-
Design and Performance of the Spin Asymmetries of the Nucleon Experiment
Authors:
J. D. Maxwell,
W. R. Armstrong,
S. Choi,
M. K. Jones,
H. Kang,
A. Liyanage,
Z. -E. Meziani,
J. Mulholland,
L. Ndukum,
O. A. Rondon,
A. Ahmidouch,
I. Albayrak,
A. Asaturyan,
O. Ates,
H. Baghdasaryan,
W. Boeglin,
P. Bosted,
E. Brash,
J. Brock,
C. Butuceanu,
M. Bychkov,
C. Carlin,
P. Carter,
C. Chen,
J. -P. Chen
, et al. (80 additional authors not shown)
Abstract:
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employin…
▽ More
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target whose magnetic field direction could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables $A_1$, $A_2$, $g_1$, $g_2$ and moment $d_2$ of the proton. This document summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.
△ Less
Submitted 21 December, 2017; v1 submitted 22 November, 2017;
originally announced November 2017.
-
The SeaQuest Spectrometer at Fermilab
Authors:
SeaQuest Collaboration,
C. A. Aidala,
J. R. Arrington,
C. Ayuso,
B. M. Bowen,
M. L. Bowen,
K. L. Bowling,
A. W. Brown,
C. N. Brown,
R. Byrd,
R. E. Carlisle,
T. Chang,
W. -C. Chang,
A. Chen,
J. -Y. Chen,
D. C. Christian,
X. Chu,
B. P. Dannowitz,
M. Daugherity,
M. Diefenthaler,
J. Dove,
C. Durandet,
L. El Fassi,
E. Erdos,
D. M. Fox
, et al. (73 additional authors not shown)
Abstract:
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets…
▽ More
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.
△ Less
Submitted 9 February, 2019; v1 submitted 29 June, 2017;
originally announced June 2017.
-
A Large Ungated TPC with GEM Amplification
Authors:
M. Berger,
M. Ball,
L. Fabbietti,
B. Ketzer,
R. Arora,
R. Beck,
F. Böhmer,
J. -C. Chen,
F. Cusanno,
S. Dørheim,
J. Hehner,
N. Herrmann,
C. Höppner,
D. Kaiser,
M. Kis,
V. Kleipa,
I. Konorov,
J. Kunkel,
N. Kurz,
Y. Leifels,
P. Müllner,
R. Münzer,
S. Neubert,
J. Rauch,
C. J. Schmidt
, et al. (6 additional authors not shown)
Abstract:
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons…
▽ More
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC).
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Sympathetic ground state cooling and time-dilation shifts in an $^{27}\text{Al}^+$ optical clock
Authors:
J. -S. Chen,
S. M. Brewer,
C. W. Chou,
D. J. Wineland,
D. R. Leibrandt,
D. B. Hume
Abstract:
We report on Raman sideband cooling of ${^{25}\text{Mg}^+}$ to sympathetically cool the secular modes of motion in a $^{25}\text{Mg}^+$-$^{27}\!\text{Al}^+$ two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D side…
▽ More
We report on Raman sideband cooling of ${^{25}\text{Mg}^+}$ to sympathetically cool the secular modes of motion in a $^{25}\text{Mg}^+$-$^{27}\!\text{Al}^+$ two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D sideband cooling in our system are discussed. We characterize the residual energy and heating rates of all of the secular modes of motion and estimate a secular motion time-dilation shift of ${-(1.9 \pm 0.1)\times 10^{-18}}$ for an ${^{27}\text{Al}^+}$ clock at a typical clock probe duration of $150$ ms. This is a 50-fold reduction in the secular motion time-dilation shift uncertainty in comparison with previous ${^{27}\text{Al}^+}$ clocks.
△ Less
Submitted 16 February, 2017; v1 submitted 17 August, 2016;
originally announced August 2016.
-
Hall A Annual Report 2012
Authors:
S. Riordan,
C. Keppel,
K. Aniol,
J. Annand,
J. Arrington,
T. Averett,
C. Ayerbe Gayoso,
E. Brash,
G. D. Cates,
J. -P. Chen,
E. Chudakov,
D. Flay,
G. B. Franklin,
M. Friedman,
O. Glamazdin,
J. Gomez,
C. Hanretty,
J. -O. Hansen,
C. Hyde,
M. K. Jones,
I. Korover,
J. J. LeRose,
R. A. Lindgren,
N. Liyanage,
E. Long
, et al. (24 additional authors not shown)
Abstract:
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.