-
Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos
Authors:
LiquidO Consortium,
:,
A. Cabrera,
M. Chen,
F. Mantovani,
A. Serafini,
V. Strati,
J. Apilluelo,
L. Asquith,
J. L. Beney,
T. J. C. Bezerra,
M. Bongrand,
C. Bourgeois,
D. Breton,
M. Briere,
J. Busto,
A. Cadiou,
E. Calvo,
V. Chaumat,
E. Chauveau,
B. J. Cattermole,
P. Chimenti,
C. Delafosse,
H. de Kerret,
S. Dusini
, et al. (55 additional authors not shown)
Abstract:
The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity…
▽ More
The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity dominated by potassium (40K) and the decay chains of uranium (238U) and thorium (232Th). This radiogenic energy output is critical to planetary dynamics and must be accurately measured for a complete understanding of the overall heat budget and thermal history of the Earth. Detecting geoneutrinos remains the only direct probe to do so and constitutes a challenging objective in modern neutrino physics. In particular, the intriguing potassium geoneutrinos have never been observed and thus far have been considered impractical to measure. We propose here a novel approach for potassium geoneutrino detection using the unique antimatter signature of antineutrinos to reduce the otherwise overwhelming backgrounds to observing this rarest signal. The proposed detection framework relies on the innovative LiquidO detection technique to enable positron (e+) identification and antineutrino interactions with ideal isotope targets identified here for the first time. We also provide the complete experimental methodology to yield the first potassium geoneutrino discovery.
△ Less
Submitted 23 August, 2023; v1 submitted 8 August, 2023;
originally announced August 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Calibration of the scintillation of cerium-doped yttrium aluminum garnet crystals irradiated by monoenergetic 4 MeV energy electrons
Authors:
K. Burdonov,
P. Forestier-Colleoni,
J. -N. Cayla,
T. Ceccotti,
S. Chance,
V. Chaumat,
N. Delerue,
H. Guler,
V. Lelasseux,
B. Lucas,
J. Fuchs
Abstract:
This paper presents the results of measurements of fluorescing cerium-doped yttrium aluminum garnet crystals after being irradiated by an accelerated electron beam with energy of around 4 MeV. The measurements were performed using the PHIL linear accelerator at LAL (France). We observe linear dependence of the crystal emission to the electron beam charge and the isotropy of the photon emission. We…
▽ More
This paper presents the results of measurements of fluorescing cerium-doped yttrium aluminum garnet crystals after being irradiated by an accelerated electron beam with energy of around 4 MeV. The measurements were performed using the PHIL linear accelerator at LAL (France). We observe linear dependence of the crystal emission to the electron beam charge and the isotropy of the photon emission. We provide the calibration coefficients of the photon emission depending on the charge of the accelerated electron beam for two crystals originating from two different manufacturers.
△ Less
Submitted 3 March, 2021;
originally announced March 2021.
-
Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment
Authors:
F. M. Addesa,
L. Burmistrov,
D. Breton,
G. Cavoto,
V. Chaumat,
S. Dubos,
L. Esposito,
F. Galluccio,
M. Garattini,
F. Iacoangeli,
J. Maalmi,
D. Mirarchi,
A. Natochii,
V. Puill,
R. Rossi,
W. Scandale,
S. Montesano,
A. Stocchi
Abstract:
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on…
▽ More
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on thin fused silica bars in the beam pipe vacuum which intercept charged particles and generate Cherenkov light. The first version of the CpFM is installed since 2015 in the crystal-assisted collimation setup of the UA9 experiment. In this paper the procedures to make the detector operational and fully integrated in the UA9 setup are described. The most important standard operations of the detector are presented. They have been used to commission and characterize the detector, providing moreover the measurement of the integrated channeled beam profile and several functionality tests as the determination of the crystal bending angle.
The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and the results are applied to the flux measurement discussed here in detail.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
Status report of the ESCULAP project at Orsay: External injection of low energy electrons in a Plasma
Authors:
Elsa Baynard,
Christelle Bruni,
Kevin Cassou,
Vincent Chaumat,
Nicolas Delerue,
Julien Demailly,
Denis Douillet,
Noureddine El Kamchi,
David Garzella,
Olivier Guilbaud,
Stephane Jenzer,
Sophie Kazamias,
Viacheslav Kubytskyi,
Pierre Lepercq,
Bruno Lucas,
Gilles Maynard,
Olivier Neveu,
Moana Pittman,
Rui Prazeres,
Harsh Purwar,
David Ros,
Cynthia Vallerand,
Ke Wang
Abstract:
The ESCULAP project aims at studying external injection of low energy (\SI{10}{MeV}) electrons in a plasma in the quasilinear regime. This facility will use the photo injector PHIL and the high power laser LASERIX. We will give a status report of the preliminary work on the facility and the status of the two machines. We will also present the results of simulations showing the expected performance…
▽ More
The ESCULAP project aims at studying external injection of low energy (\SI{10}{MeV}) electrons in a plasma in the quasilinear regime. This facility will use the photo injector PHIL and the high power laser LASERIX. We will give a status report of the preliminary work on the facility and the status of the two machines. We will also present the results of simulations showing the expected performances of the facility.
△ Less
Submitted 5 March, 2018; v1 submitted 26 February, 2018;
originally announced February 2018.
-
Modelling of laser-plasma acceleration of relativistic electrons in the frame of ESCULAP project
Authors:
E. Baynard,
C. Bruni,
K. Cassou,
V. Chaumat,
N. Delerue,
J. Demailly,
D. Douillet,
N. El Kamchi,
D. Garzella,
O. Guilbaud,
S. Jenzer,
S. Kazamias,
V. Kubytskyi,
P. Lepercq,
B. Lucas,
G. Maynard,
O. Neveu,
M. Pittman,
R. Prazeres,
H. Purwar,
D. Ros,
K. Wang
Abstract:
We present numerical simulations results on the injection and acceleration of a 10 MeV, 10 pC electrons beam in a plasma wave generated in a gas cell by a 2J, 45 fs laser beam. This modeling is related to the ESCULAP project in which the electrons accelerated by the PHIL photo-injector is injected in a gas cell irradiated by the laser beam of the LASERIX system. Extensive modeling of the experimen…
▽ More
We present numerical simulations results on the injection and acceleration of a 10 MeV, 10 pC electrons beam in a plasma wave generated in a gas cell by a 2J, 45 fs laser beam. This modeling is related to the ESCULAP project in which the electrons accelerated by the PHIL photo-injector is injected in a gas cell irradiated by the laser beam of the LASERIX system. Extensive modeling of the experiment was performed in order to determine optimal parameters of the laser plasma configurations. This was done with the newly developed numerical code WakeTraj . We propose a configuration that benefits of a highly compressed electron bunch and for which the injected electron beam can be efficiently coupled to the plasma wave and accelerated up to 140 MeV, with an energy spread lower than 5%.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Longitudinal compression and transverse matching of electron bunch for external injection LPWA at ESCULAP
Authors:
K. Wang,
E. Baynard,
C. Bruni,
K. Cassou,
V. Chaumat,
N. Delerue,
J. Demailly,
D. Douillet,
N. El. Kamchi,
D. Garzella,
O. Guilbaud,
S. Jenzer,
S. Kazamias,
V. Kubytskyi,
P. Lepercq,
B. Lucas,
G. Maynard,
O. Neveu,
M. Pittman,
R. Prazeres,
H. Purwar,
D. Ros
Abstract:
We present theoretical and numerical studies of longitudinal compression and transverse matching of electron bunch before injecting into the Laser-plasma Wake Field Accelerator (LWFA) foreseen at the ESCULAP project in ORSAY. Longitudinal compression is performed with a dogleg chicane, the chicane is designed based on theory of beam optics, beam dynamics in dogleg is studied with ImpactT and cross…
▽ More
We present theoretical and numerical studies of longitudinal compression and transverse matching of electron bunch before injecting into the Laser-plasma Wake Field Accelerator (LWFA) foreseen at the ESCULAP project in ORSAY. Longitudinal compression is performed with a dogleg chicane, the chicane is designed based on theory of beam optics, beam dynamics in dogleg is studied with ImpactT and cross checked with CSRtrack, both 3D space charge (SC) and coherent synchrotron radiation (CSR) effects are included. Simulation results show that the energy chirp at the dogleg entrance should be smaller than the nominal optic design value, in order to compensate the negative energy chirp increase caused by longitudinal SC, while CSR can be ignored in our case. With an optimized configuration, the electron bunch ($\sim$10MeV, 10pC) is compressed from 0.9ps RMS to 70fs RMS (53fs FWHM), with a peak current of 152A. Transverse matching is realized with a doublet and a triplet, they are matched with Madx and the electron bunch is tracked with ImpactT, simulation results show little difference with the nominal design values, that is due to the SC effect. Finally, by simply adjusting the quadrupole strength, a preliminary optimized configuration has been achieved, that matches the Courant-Snyder (C-S) parameters to $α_{x}=0.01$,$α_{y}=-0.02$, $β_{x}=0.014$m,$β_{y}=0.012$m at the plasma entrance.
△ Less
Submitted 5 December, 2017;
originally announced December 2017.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
PHIL photoinjector test line
Authors:
M. Alves,
C. Arnault,
D. Auguste,
J. L. Babigeon,
F. Blot,
J. Brossard,
C. Bruni,
S. Cavalier,
J. N. Cayla,
V. Chaumat,
J. Collin,
M. Dehamme,
M. Demarest,
J. P. Dugal,
M. Elkhaldi,
I. Falleau,
A. Gonnin,
M. Jore,
E. Jules,
B. Leluan,
P. Lepercq,
F. Letellier,
E. Mandag,
J. C. Marrucho,
B. Mercier
, et al. (8 additional authors not shown)
Abstract:
LAL is now equiped with its own platform for photoinjectors tests and Research and Developement, named PHIL (PHotoInjectors at LAL). This facility has two main purposes: push the limits of the photoinjectors performances working on both the design and the associated technology and provide a low energy (MeV) short pulses (ps) electron beam for the interested users. Another very important goal of th…
▽ More
LAL is now equiped with its own platform for photoinjectors tests and Research and Developement, named PHIL (PHotoInjectors at LAL). This facility has two main purposes: push the limits of the photoinjectors performances working on both the design and the associated technology and provide a low energy (MeV) short pulses (ps) electron beam for the interested users. Another very important goal of this machine will be to provide an opportunity to form accelerator physics students, working in a high technology environment. To achieve this goal a test line was realised equipped with an RF source, magnets and beam diagnostics. In this article we will desrcibe the PHIL beamline and its characteristics together with the description of the first two photoinjector realised in LAL and tested: the ALPHAX and the PHIN RF Guns.
△ Less
Submitted 24 September, 2012;
originally announced September 2012.