Diamond-optic enhanced photon collection efficiency for sensing with nitrogen-vacancy centers
Authors:
Muhib Omar,
Andreas Conta,
Andreas Westerhoff,
Raphael Hasse,
Georgios Chatzidrosos,
Dmitry Budker,
Arne Wickenbrock
Abstract:
We present a design to increase the amount of collected fluorescence emitted by nitrogen-vacancy color centers in diamond used for quantum-sensing. An improvement was measured in collected fluorescence when comparing oppositely faced emitting surfaces by a factor of 3.8(1). This matches ray-tracing simulation results. This design therefore improves on the shot noise limited sensitivity in optical…
▽ More
We present a design to increase the amount of collected fluorescence emitted by nitrogen-vacancy color centers in diamond used for quantum-sensing. An improvement was measured in collected fluorescence when comparing oppositely faced emitting surfaces by a factor of 3.8(1). This matches ray-tracing simulation results. This design therefore improves on the shot noise limited sensitivity in optical read-out based measurements of for instance magnetic and electric fields, pressure, temperature and rotations.
△ Less
Submitted 16 January, 2023;
originally announced January 2023.
-
Battery characterization via eddy-current imaging with nitrogen-vacancy centers in diamond
Authors:
Xue Zhang,
Georgios Chatzidrosos,
Yinan Hu,
Huijie Zheng,
Arne Wickenbrock,
Alexej Jerschow,
Dmitry Budker
Abstract:
Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries in a noninvasive detection. We demonstrate a microwave-free AC magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between NV centers and individual substitutional nitrogen (P1) centers…
▽ More
Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries in a noninvasive detection. We demonstrate a microwave-free AC magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between NV centers and individual substitutional nitrogen (P1) centers occurring at 51.2 mT. We apply the technique to non-destructive solid-state battery imaging. By detecting the eddy-current-induced magnetic field of the battery, we distinguish a defect on the external electrode and identify structural anomalies within the battery body. The achieved spatial resolution is $360\,μ\rm m$. The maximum magnetic field and phase shift generated by the battery at the modulation frequency of 5 kHz are estimated as 0.04 mT and 0.03 rad respectively.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Probing topological spin structures using light-polarization and magnetic microscopy
Authors:
Till Lenz,
Georgios Chatzidrosos,
Zhiyuan Wang,
Lykourgos Bougas,
Yannick Dumeige,
Arne Wickenbrock,
Nico Kerber,
Jakub Zázvorka,
Fabian Kammerbauer,
Mathias Kläui,
Zeeshawn Kazi,
Kai-Mei C. Fu,
Kohei Itoh,
Hideyuki Watanabe,
Dmitry Budker
Abstract:
We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.
We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.
△ Less
Submitted 7 October, 2020;
originally announced October 2020.
-
High homogeneity permanent magnet for diamond magnetometry
Authors:
Arne Wickenbrock,
Huijie Zheng,
Georgios Chatzidrosos,
Joseph Shaji Rebeirro,
Tim Schneemann,
Peter Bluemler
Abstract:
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while kee** stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup.…
▽ More
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while kee** stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for the proposed use.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
Microwave-free vector magnetometry with nitrogen-vacancy centers along a single axis in diamond
Authors:
Huijie Zheng,
Zhiyin Sun,
Georgios Chatzidrosos,
Chen Zhang,
Kazuo Nakamura,
Hitoshi Sumiya,
Takeshi Ohshima,
Junichi Isoya,
Jörg Wrachtrup,
Arne Wickenbrock,
Dmitry Budker
Abstract:
Sensing vector magnetic fields is critical to many applications in fundamental physics, bioimaging, and material science. Magnetic-field sensors exploiting nitrogen-vacancy (NV) centers are particularly compelling as they offer high sensitivity and spatial resolution even at nanoscale. Achieving vector magnetometry has, however, often required applying microwaves sequentially or simultaneously, li…
▽ More
Sensing vector magnetic fields is critical to many applications in fundamental physics, bioimaging, and material science. Magnetic-field sensors exploiting nitrogen-vacancy (NV) centers are particularly compelling as they offer high sensitivity and spatial resolution even at nanoscale. Achieving vector magnetometry has, however, often required applying microwaves sequentially or simultaneously, limiting the sensors' applications under cryogenic temperature. Here we propose and demonstrate a microwave-free vector magnetometer that simultaneously measures all Cartesian components of a magnetic field using NV ensembles in diamond. In particular, the present magnetometer leverages the level anticrossing in the triplet ground state at 102.4 mT, allowing the measurement of both longitudinal and transverse fields with a wide bandwidth from zero to megahertz range. Full vector sensing capability is proffered by modulating fields along the preferential NV axis and in the transverse plane and subsequent demodulation of the signal. This sensor exhibits a root mean square noise floor of about 300 pT/Hz^(1/2) in all directions. The present technique is broadly applicable to both ensemble sensors and potentially also single-NV sensors, extending the vector capability to nanoscale measurement under ambient temperatures.
△ Less
Submitted 14 April, 2020; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Infrared laser magnetometry with a NV doped diamond intracavity etalon
Authors:
Yannick Dumeige,
Jean-François Roch,
Fabien Bretenaker,
Thierry Debuisschert,
Victor Acosta,
Christoph Becher,
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Alexander Wilzewski,
Dmitry Budker
Abstract:
We propose an hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magne…
▽ More
We propose an hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magnetometer that can be operated at room-temperature. The sensitivity to the magnetic field limited by the photon shot-noise of the output laser beam is estimated to be around $250~\mathrm{fT/\sqrt{Hz}}$. Unlike usual NV center infrared magnetometry, this method would not require an external frequency stabilized laser. Since the proposed system relies on the competition between the laser threshold and an intracavity absorption, such laser-based optical sensor could be easily adapted to a broad variety of physical systems.
△ Less
Submitted 18 October, 2018;
originally announced October 2018.
-
Eddy-current imaging with nitrogen-vacancy centers in diamond
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Huijie Zheng,
Oleg Tretiak,
Yu Yang,
Dmitry Budker
Abstract:
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is…
▽ More
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is calculated as 8$\times 10 ^{5}$\,S/m\,$\sqrt[]{\textrm{Hz}}$ at 3.5\,MHz, for a cylindrical sample with radius $r_0$\,=\,1\,mm and height $h$\,=\,0.1\,mm (volume $\sim$\,0.3\,mm$^3$), at a distance of 0.5\,mm. In comparison with existing technologies, the diamond-based device exhibits a superior bandwidth and spatial resolution. In particular, we demonstrate a flat frequency response from DC to 3.5 MHz and a spatial resolution of 348\,$\pm$\,2\,$μ$m.
△ Less
Submitted 5 October, 2018;
originally announced October 2018.
-
Miniature cavity-enhanced diamond magnetometer
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Nathan Leefer,
Teng Wu,
Kasper Jensen,
Yannick Dumeige,
Dmitry Budker
Abstract:
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/…
▽ More
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/$\sqrt{\rm{Hz}}$, a projected photon shot-noise-limited sensitivity of 22 pT/$\sqrt{\rm{Hz}}$ and an estimated quantum projection-noise-limited sensitivity of 0.43 pT/$\sqrt{\rm{Hz}}$ with the sensing volume of $\sim$ 390 $μ$m $\times$ 4500 $μ$m$^{2}$. The presented miniaturized device is the basis for an endoscopic magnetic field sensor for biomedical applications.