A novel inverse algorithm to solve IPO-IMPT of proton FLASH therapy with sparse filters
Authors:
Nathan Harrison,
Minglei Kang,
Ruirui Liu,
Serdar Charyyev,
Niklas Wahl,
Wei Liu,
Jun Zhou,
Kristin A. Higgins,
Charles Simone,
Jeffrey Bradley,
William S. Dynan,
Liyong Lin
Abstract:
Purpose:The recently proposed IPO-IMPT framework allows simultaneous optimization of dose, dose rate, and LET for FLASH treatment planning. Finding solutions to IPO-IMPT is difficult due to computational intensiveness. Nevertheless, an inverse solution that simultaneously specifies the geometry of a sparse filter and weights of a proton intensity map is desirable for both clinical and preclinical…
▽ More
Purpose:The recently proposed IPO-IMPT framework allows simultaneous optimization of dose, dose rate, and LET for FLASH treatment planning. Finding solutions to IPO-IMPT is difficult due to computational intensiveness. Nevertheless, an inverse solution that simultaneously specifies the geometry of a sparse filter and weights of a proton intensity map is desirable for both clinical and preclinical applications. Such solutions can reduce effective biological dose to organs at risk in cancer patients as well as reduce the number of animal irradiations needed to derive extra biological dose models in preclinical studies.
Methods:Unlike our initial forward heuristic, this inverse IPO-IMPT solution includes simultaneous optimization of sparse range compensation, sparse range modulation, and spot intensity. The daunting computational tasks vital to this endeavor were resolved iteratively with a distributed computing framework to enable Simultaneous Intensity and Energy Modulation and Compensation (SIEMAC). SIEMAC was demonstrated on a human lung cancer patient and a minipig.
Results:SIEMAC improves maps of spot intensities and patient-field-specific sparse range compensators and range modulators. For the lung cancer patient, at our max nozzle current of 300 nA, dose rate coverage above 100 Gy/s increased from 57% to 96% in the lung and from 93% to 100% in the heart, and LET coverage above 4 keV/um dropped from 68% to 9% in the lung and from 26% to <1% in the heart. For a simple minipig plan, the FWHM of the dose, dose rate, and LET distributions decreased by 30%, 1.6%, and 57%, respectively, again with similar target dose coverage, thus reducing uncertainty in these quantities for preclinical studies.
Conclusion:The inverse solution to IPO-IMPT demonstrated the capability to simultaneously modulate sub-spot proton energy and intensity distributions for clinical and preclinical studies.
△ Less
Submitted 19 April, 2023; v1 submitted 22 February, 2023;
originally announced February 2023.
-
Validation of the Quantum Physics Processes Underlying the Integrated Optimization of Proton FLASH Radiotherapy
Authors:
Nathan Harrison,
Serdar Charyyev,
Cristina Oancea,
Alexander Stanforth,
Shuang Zhou,
William Dynan,
Tiezhi Zhang,
Steven Biegalski,
Liyong Lin
Abstract:
FLASH is a new treatment modality that requires optimization of dose, dose rate, and LET. Here we validate these three quantities under FLASH conditions, which includes the quantum uncertainty in the time-dependent instantaneous dose rate (IDR) curves and LET spectra that underlie the newly proposed integrated optimization framework.
Measurements of dose, IDR, and LET were performed at the Emory…
▽ More
FLASH is a new treatment modality that requires optimization of dose, dose rate, and LET. Here we validate these three quantities under FLASH conditions, which includes the quantum uncertainty in the time-dependent instantaneous dose rate (IDR) curves and LET spectra that underlie the newly proposed integrated optimization framework.
Measurements of dose, IDR, and LET were performed at the Emory Proton Therapy Center using a FLASH proton beam with a nominal energy of 250 MeV and a 3D printed ridge filter. Because 3D printing resin is made from a proprietary chemical formula, we developed a method for realistically characterizing and modeling the material in simulations. Absolute dose in 3D space was measured using a 2D MatriXX PT detector as well as by a novel 4D multi-layer strip ionization chamber (MLSIC), which also simultaneously measures IDR. Further timing data was measured in the secondary beam by detecting prompt gammas using a Minipix Timepix3; a second detector, Advapix Timepix3, was used to measure LET. To account for the quantum mechanical nature of particle transport, we developed a technique for detecting individual protons within a high flux primary beam, which was necessary for properly measuring LET spectra.
TOPAS simulations agreed with measurement, with absolute dose typically having a gamma passing rate of at least 95% (3 mm/3% criteria). Likewise, IDR and LET showed good agreement, with averaged IDR values agreeing within 0.3% with fluctuations on the order of 10%, and LET distributions overlap** by at least 85% and showing an increase in high LET components (greater than 4 keV/um) with increasing depth.
As LET and FLASH optimization continues to grow in popularity, measuring IDR, LET, and dose will become even more important, and we expect that the methods described here will prove to be useful tools in radiotherapy treatment planning and QA.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
Measurement of the time structure of FLASH beams using prompt gamma rays and secondary neutrons as surrogates
Authors:
Serdar Charyyev,
Ruirui Liu,
Xiaofeng Yang,
Jun Zhou,
Anees Dhabaan,
William S. Dynan,
Cristina Oancea,
Liyong Lin
Abstract:
We aim to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH radiotherapy using a pixelated semiconductor detector. Measurements of the time structure of FLASH irradiations were performed using fast, pixelated spectral detectors, AdvaPIX-TPX3 and Minipix-TPX3. The latter has a fraction of its sensor coated with a neutron sensitive material. With litt…
▽ More
We aim to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH radiotherapy using a pixelated semiconductor detector. Measurements of the time structure of FLASH irradiations were performed using fast, pixelated spectral detectors, AdvaPIX-TPX3 and Minipix-TPX3. The latter has a fraction of its sensor coated with a neutron sensitive material. With little or no dead time and an ability to resolve events that are closely spaced in time (tens of ns), both detectors can accurately determine IRTs as long as pile-ups are avoided. To avoid pile-ups, we placed the detectors beyond the Bragg peak or at a large scattering angle. We acquired prompt gamma rays and secondary neutrons and calculated IRTs based on timestamps of the first (beam-on) and the last (beam-off) charged species. We also measured scan times in x, y, and diagonal directions. We performed these measurements for a single spot, a small animal field, a patient field, and a ridge filter optimized field to demonstrate in vivo online monitoring of IRT. All measurements were compared to vendor log files. Differences between measurements and log files for a single spot, a small animal field, and a patient field were within 1%, 0.3% and 1%, respectively. In vivo monitoring of IRTs was accurate within 0.1% for AdvaPIX-TPX3 and within 6.1% for Minipix-TPX3. The scan times in x, y, and diagonal directions were 4.0, 3.4, and 4.0 ms, respectively. Overall, the AdvaPIX-TPX3 can measure FLASH IRTs within 1% accuracy, indicating that prompt gamma rays are a good surrogate for primary protons. The Minipix-TPX3 showed a higher discrepancy, suggesting a need for further investigation. The scan times (3.4 \pm 0.05 ms) in the 60-mm distance of y-direction were less than (4.0 \pm 0.06 ms) in the 24-mm distance of x-direction, confirming the much faster scanning speed of the Y magnets than that of X.
△ Less
Submitted 2 September, 2022;
originally announced September 2022.
-
Characterization of 250 MeV protons from Varian ProBeam pencil beam scanning system for FLASH radiation therapy
Authors:
Serdar Charyyev,
Chih-Wei Chang,
Mingyao Zhu,
Liyong Lin,
Katja Langen,
Anees Dhabaan
Abstract:
Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it is not typical to use 250 MeV protons for routine clinical treatments and as such 250 MeV may not have been characterized in the commissioning. In this study, w…
▽ More
Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it is not typical to use 250 MeV protons for routine clinical treatments and as such 250 MeV may not have been characterized in the commissioning. In this study, we aim to characterize 250 MeV protons from Varian ProBeam system for FLASH RT as well as assess the ability of clinical monitoring ionization chamber (MIC) for FLASH-readiness. We measured data needed for beam commissioning: integral depth dose (IDD) curve, spot sigma, and absolute dose calibration. To evaluate MIC, we measured output as a function of beam current. To characterize a 250 MeV FLASH beam, we measured: (1) central axis DR as a function of current and spot spacing and arrangement, (2) for a fixed spot spacing, the maximum field size that still achieves FLASH DR (i.e., > 40 Gy/s), (3) DR reproducibility. All FLASH DR measurements were performed using ion chamber for the absolute dose and irradiation times were obtained from log files. We verified dose measurements using EBT-XD films and irradiation times using a fast, pixelated spectral detector. R90 and R80 from IDD were 37.58 and 37.69 cm, and spot sigma at isocenter were σx=3.336 and σy=3.332 mm, respectively. The absolute dose output was measured as 0.377 GyE*mm2/MU for the commissioning conditions. Output was stable for beam currents up to 15 nA, and it gradually increased to 12-fold for 115 nA. DR depended on beam current, spot spacing and arrangement and could be reproduced within 4.2% variations. Even though FLASH was achieved and the largest field size that delivers FLASH DR was determined as 35x35 mm2, current MIC has DR dependence and users should measure DR each time for their FLASH applications.
△ Less
Submitted 25 January, 2023; v1 submitted 9 August, 2022;
originally announced August 2022.
-
An Integrated Biological Optimization framework for proton SBRT FLASH treatment planning allows dose, dose rate, and LET optimization using patient-specific ridge filters
Authors:
Ruirui Liu,
Serdar Charyyev,
Niklas Wahl,
Wei Liu,
Minglei Kang,
Jun Zhou,
Xiaofeng Yang,
Filipa Baltazar,
Martina Palkowitsch,
Kristin Higgins,
William Dynan,
Jeffrey Bradley,
Liyong Lin
Abstract:
Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an Integrated Biological Optimization IMPT (IBO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged LET (LETd). Methods: We d…
▽ More
Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an Integrated Biological Optimization IMPT (IBO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged LET (LETd). Methods: We developed inverse planning software to design patient-specific ridge filters that spread the Bragg peak from a fixed-energy, 250 MeV beam to a proximal beam-specific planning target volume. The software optimizes patient-specific ridge filter and uses a Monte Carlo calculation engine, based on Geant4, to provide dose and LET influence matrices. Plan optimization, using matRAD, accommodates the IBO-IMPT objective function considering dose, dose rate, and LET simultaneously with minimum MU constraints. The framework enables design of both regularly spaced and sparse-optimized ridge filters, which allow faster delivery and selective LET optimization. Volume distributions and histograms for dose, DADR, and LETd are compared using evaluation structures specific to the heart and lung. Results: We used IBO-IMPT to design ridge filters for a central lung tumor patient. The IBO-IMPT framework selectively spared heart and lung by reducing LET and increasing dose rate, relative to IMPT planning. Sparse-optimized ridge filters were superior to regularly spaced ridge filters in dose rate. Together, these innovations substantially increased the DADR in the heart and lung while maintaining good target coverage. The volume that received a FLASH dose rate of higher 40 Gy/second increased by 31% for heart and 50% for lung. Conclusion: This proof-of-concept study demonstrates the feasibility of using an IBO-IMPT framework to accomplish proton FLASH SBPT, accounting for dose, DADR, and LETd simultaneously.
△ Less
Submitted 16 July, 2022;
originally announced July 2022.
-
Learning-Based Synthetic Dual Energy CT Imaging from Single Energy CT for Stop** Power Ratio Calculation in Proton Radiation Therapy
Authors:
Serdar Charyyev,
Tonghe Wang,
Yang Lei,
Beth Ghavidel,
Jonathan J. Beitler,
Mark McDonald,
Walter J. Curran,
Tian Liu,
Jun Zhou,
Xiaofeng Yang
Abstract:
Purpose: Dual-energy CT (DECT) has been shown to derive stop** power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely implemented as SECT in proton radiation therapy simulation. This work presents a learning-based method to synthetize DECT images from SECT for proton radiation…
▽ More
Purpose: Dual-energy CT (DECT) has been shown to derive stop** power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely implemented as SECT in proton radiation therapy simulation. This work presents a learning-based method to synthetize DECT images from SECT for proton radiation therapy. Methods: The proposed method uses a residual attention generative adversarial network. Residual blocks with attention gates were used to force the model focus on the difference between DECT maps and SECT images. To evaluate the accuracy of the method, we retrospectively investigated 20 head-and-neck cancer patients with both DECT and SECT scans available. The high and low energy CT images acquired from DECT acted as learning targets in the training process for SECT datasets and were evaluated against results from the proposed method using a leave-one-out cross-validation strategy. To evaluate our method in the context of a practical application, we generated SPR maps from sDECT using physics-based dual-energy stoichiometric method and compared the maps to those generated from DECT. Results: The synthesized DECT images showed an average mean absolute error around 30 Hounsfield Unit (HU) across the whole-body volume. The corresponding SPR maps generated from synthetic DECT showed an average normalized mean square error of about 1% with reduced noise level and artifacts than those from original DECT. Conclusions: The accuracy of the synthesized DECT image by our machine-learning-based method was evaluated on head and neck patient, and potential feasibility for proton treatment planning and dose calculation was shown by generating SPR map using the synthesized DECT.
△ Less
Submitted 25 May, 2020;
originally announced May 2020.