-
Improving neutrino energy estimation of charged-current interaction events with recurrent neural networks in MicroBooNE
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
A. Barnard,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
J. Bateman,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book
, et al. (164 additional authors not shown)
Abstract:
We present a deep learning-based method for estimating the neutrino energy of charged-current neutrino-argon interactions. We employ a recurrent neural network (RNN) architecture for neutrino energy estimation in the MicroBooNE experiment, utilizing liquid argon time projection chamber (LArTPC) detector technology. Traditional energy estimation approaches in LArTPCs, which largely rely on reconstr…
▽ More
We present a deep learning-based method for estimating the neutrino energy of charged-current neutrino-argon interactions. We employ a recurrent neural network (RNN) architecture for neutrino energy estimation in the MicroBooNE experiment, utilizing liquid argon time projection chamber (LArTPC) detector technology. Traditional energy estimation approaches in LArTPCs, which largely rely on reconstructing and summing visible energies, often experience sizable biases and resolution smearing because of the complex nature of neutrino interactions and the detector response. The estimation of neutrino energy can be improved after considering the kinematics information of reconstructed final-state particles. Utilizing kinematic information of reconstructed particles, the deep learning-based approach shows improved resolution and reduced bias for the muon neutrino Monte Carlo simulation sample compared to the traditional approach. In order to address the common concern about the effectiveness of this method on experimental data, the RNN-based energy estimator is further examined and validated with dedicated data-simulation consistency tests using MicroBooNE data. We also assess its potential impact on a neutrino oscillation study after accounting for all statistical and systematic uncertainties and show that it enhances physics sensitivity. This method has good potential to improve the performance of other physics analyses.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Measurement of the differential cross section for neutral pion production in charged-current muon neutrino interactions on argon with the MicroBooNE detector
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
M. B. Brunetti,
L. Camilleri
, et al. (163 additional authors not shown)
Abstract:
We present a measurement of neutral pion production in charged-current interactions using data recorded with the MicroBooNE detector exposed to Fermilab's booster neutrino beam. The signal comprises one muon, one neutral pion, any number of nucleons, and no charged pions. Studying neutral pion production in the MicroBooNE detector provides an opportunity to better understand neutrino-argon interac…
▽ More
We present a measurement of neutral pion production in charged-current interactions using data recorded with the MicroBooNE detector exposed to Fermilab's booster neutrino beam. The signal comprises one muon, one neutral pion, any number of nucleons, and no charged pions. Studying neutral pion production in the MicroBooNE detector provides an opportunity to better understand neutrino-argon interactions, and is crucial for future accelerator-based neutrino oscillation experiments. Using a dataset corresponding to $6.86 \times 10^{20}$ protons on target, we present single-differential cross sections in muon and neutral pion momenta, scattering angles with respect to the beam for the outgoing muon and neutral pion, as well as the opening angle between the muon and neutral pion. Data extracted cross sections are compared to generator predictions. We report good agreement between the data and the models for scattering angles, except for an over-prediction by generators at muon forward angles. Similarly, the agreement between data and the models as a function of momentum is good, except for an underprediction by generators in the medium momentum ranges, $200-400$ MeV for muons and $100-200$ MeV for pions.
△ Less
Submitted 6 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Search for heavy neutral leptons in electron-positron and neutral-pion final states with the MicroBooNE detector
Authors:
MicroBooNE collaboration,
P. Abratenko,
O. Alterkait,
D. Andrade Aldana,
L. Arellano,
J. Asaadi,
A. Ashkenazi,
S. Balasubramanian,
B. Baller,
G. Barr,
D. Barrow,
J. Barrow,
V. Basque,
O. Benevides Rodrigues,
S. Berkman,
A. Bhanderi,
A. Bhat,
M. Bhattacharya,
M. Bishai,
A. Blake,
B. Bogart,
T. Bolton,
J. Y. Book,
M. B. Brunetti,
L. Camilleri
, et al. (163 additional authors not shown)
Abstract:
We present the first search for heavy neutral leptons (HNL) decaying into $νe^+e^-$ or $νπ^0$ final states in a liquid-argon time projection chamber using data collected with the MicroBooNE detector. The data were recorded synchronously with the NuMI neutrino beam from Fermilab's Main Injector corresponding to a total exposure of $7.01 \times 10^{20}$ protons on target. We set upper limits at the…
▽ More
We present the first search for heavy neutral leptons (HNL) decaying into $νe^+e^-$ or $νπ^0$ final states in a liquid-argon time projection chamber using data collected with the MicroBooNE detector. The data were recorded synchronously with the NuMI neutrino beam from Fermilab's Main Injector corresponding to a total exposure of $7.01 \times 10^{20}$ protons on target. We set upper limits at the $90\%$ confidence level on the mixing parameter $\lvert U_{μ4}\rvert^2$ in the mass ranges $10\le m_{\rm HNL}\le 150$ MeV for the $νe^+e^-$ channel and $150\le m_{\rm HNL}\le 245$ MeV for the $νπ^0$ channel, assuming $\lvert U_{e 4}\rvert^2 = \lvert U_{τ4}\rvert^2 = 0$. These limits represent the most stringent constraints in the mass range $35<m_{\rm HNL}<175$ MeV and the first constraints from a direct search for $νπ^0$ decays.
△ Less
Submitted 12 January, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Time-encoded pseudo-continuous arterial spin labeling: increasing SNR in ASL angiography
Authors:
Joseph G. Woods,
S. Sophie Schauman,
Mark Chiew,
Michael A. Chappell,
Thomas W. Okell
Abstract:
Purpose: Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the improvements in SNR from using larger flip angles, made possible…
▽ More
Purpose: Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the improvements in SNR from using larger flip angles, made possible by the shorter readout, are quantitatively investigated.
Methods: The SNR of a conventional (sequential) protocol with 9 readouts and a 4-by-3 time-encoded protocol with 3 readouts (giving 9 matched timepoints) were directly compared using simulations and in vivo data. Both protocols were compared using readouts with constant (CFA) and variable flip angles (VFA), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored.
Results: The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared to CFAs by 25% and 21% for the sequential and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest optimizing the background suppression could improve in vivo SNR by a further 16%.
Conclusion: Time-encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles which can double the SNR compared to a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.
△ Less
Submitted 1 April, 2022;
originally announced April 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Low-Energy Physics in Neutrino LArTPCs
Authors:
D. Caratelli,
W. Foreman,
A. Friedland,
S. Gardiner,
I. Gil-Botella,
G. Karagiorgi,
M. Kirby,
G. Lehmann Miotto,
B. R. Littlejohn,
M. Mooney,
J. Reichenbacher,
A. Sousa,
K. Scholberg,
J. Yu,
T. Yang,
S. Andringa,
J. Asaadi,
T. J. C. Bezerra,
F. Capozzi,
F. Cavanna,
E. Church,
A. Himmel,
T. Junk,
J. Klein,
I. Lepetic
, et al. (264 additional authors not shown)
Abstract:
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below…
▽ More
In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon do**. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
N. Anfimov,
A. Ankowski,
M. Antonova,
S. Antusch
, et al. (1041 additional authors not shown)
Abstract:
This report describes the conceptual design of the DUNE near detector
This report describes the conceptual design of the DUNE near detector
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
J-PARC Neutrino Beamline Upgrade Technical Design Report
Authors:
K. Abe,
H. Aihara,
A. Ajmi,
C. Alt,
C. Andreopoulos,
M. Antonova,
S. Aoki,
Y. Asada,
Y. Ashida,
A. Atherton,
E. Atkin,
S. Ban,
F. C. T. Barbato,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz,
A. Beloshapkin,
V. Berardi,
L. Berns,
S. Bhadra,
J. Bian,
S. Bienstock,
A. Blondel,
S. Bolognesi
, et al. (360 additional authors not shown)
Abstract:
In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to $2\times{}10^{22}$ protons-on-target in the next decade, aiming at an initial observation of CP violation with $3σ$ or higher significance in the case of maximal CP violation. Methods to increase the neut…
▽ More
In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to $2\times{}10^{22}$ protons-on-target in the next decade, aiming at an initial observation of CP violation with $3σ$ or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described.
△ Less
Submitted 14 August, 2019;
originally announced August 2019.
-
Measurement of the $ν_μ$ charged-current cross sections on water, hydrocarbon, iron, and their ratios with the T2K on-axis detectors
Authors:
K. Abe,
R. Akutsu,
A. Ali,
C. Andreopoulos,
L. Anthony,
M. Antonova,
S. Aoki,
A. Ariga,
Y. Ashida,
Y. Awataguchi,
Y. Azuma,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
C. Barry,
M. Batkiewicz-Kwasniak,
F. Bench,
V. Berardi,
S. Berkman,
R. M. Berner,
L. Berns,
S. Bhadra,
S. Bienstock,
A. Blondely
, et al. (292 additional authors not shown)
Abstract:
We report a measurement of the flux-integrated $ν_μ$ charged-current cross sections on water, hydrocarbon, and iron in the T2K on-axis neutrino beam with a mean neutrino energy of 1.5 GeV. The measured cross sections on water, hydrocarbon, and iron are $σ^{\rm{H_{2}O}}_{\rm{CC}}$ = (0.840$\pm 0.010$(stat.)$^{+0.10}_{-0.08}$(syst.))$\times$10$^{-38}$cm$^2$/nucleon, $σ^{\rm{CH}}_{\rm{CC}}$ = (0.817…
▽ More
We report a measurement of the flux-integrated $ν_μ$ charged-current cross sections on water, hydrocarbon, and iron in the T2K on-axis neutrino beam with a mean neutrino energy of 1.5 GeV. The measured cross sections on water, hydrocarbon, and iron are $σ^{\rm{H_{2}O}}_{\rm{CC}}$ = (0.840$\pm 0.010$(stat.)$^{+0.10}_{-0.08}$(syst.))$\times$10$^{-38}$cm$^2$/nucleon, $σ^{\rm{CH}}_{\rm{CC}}$ = (0.817$\pm 0.007$(stat.)$^{+0.11}_{-0.08}$(syst.))$\times$10$^{-38}$cm$^2$/nucleon, and $σ^{\rm{Fe}}_{\rm{CC}}$ = (0.859$\pm 0.003$(stat.) $^{+0.12}_{-0.10}$(syst.))$\times$10$^{-38}$cm$^2$/nucleon respectively, for a restricted phase space of induced muons: $θ_μ<45^{\circ}$ and $p_μ>$0.4 GeV/$c$ in the laboratory frame. The measured cross section ratios are ${σ^{\rm{H_{2}O}}_{\rm{CC}}}/{σ^{\rm{CH}}_{\rm{CC}}}$ = 1.028$\pm 0.016$(stat.)$\pm 0.053$(syst.), ${σ^{\rm{Fe}}_{\rm{CC}}}/{σ^{\rm{H_{2}O}}_{\rm{CC}}}$ = 1.023$\pm 0.012$(stat.)$\pm 0.058$(syst.), and ${σ^{\rm{Fe}}_{\rm{CC}}}/{σ^{\rm{CH}}_{\rm{CC}}}$ = 1.049$\pm 0.010$(stat.)$\pm 0.043$(syst.). These results, with an unprecedented precision for the measurements of neutrino cross sections on water in the studied energy region, show good agreement with the current neutrino interaction models used in the T2K oscillation analyses.
△ Less
Submitted 21 April, 2019;
originally announced April 2019.
-
T2K ND280 Upgrade -- Technical Design Report
Authors:
K. Abe,
H. Aihara,
A. Ajmi,
C. Andreopoulos,
M. Antonova,
S. Aoki,
Y. Asada,
Y. Ashida,
A. Atherton,
E. Atkin,
D. Attié,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz,
A. Beloshapkin,
V. Berardi,
L. Berns,
S. Bhadra,
J. Bian,
S. Bienstock,
A. Blondel,
J. Boix,
S. Bolognesi
, et al. (359 additional authors not shown)
Abstract:
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve…
▽ More
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve the physics reach of the T2K-II project. This goal is achieved by modifying the upstream part of the detector, adding a new highly granular scintillator detector (Super-FGD), two new TPCs (High-Angle TPC) and six TOF planes. Details about the detector concepts, design and construction methods are presented, as well as a first look at the test-beam data taken in Summer 2018. An update of the physics studies is also presented.
△ Less
Submitted 14 October, 2020; v1 submitted 11 January, 2019;
originally announced January 2019.