Accuracy of parameterized proton range models; a comparison
Authors:
Helge Egil Seime Pettersen,
Mamdouh Chaar,
Ilker Meric,
Odd Harald Odland,
Jarle Rambo Sølie,
Dieter Röhrich
Abstract:
An accurate calculation of proton ranges in phantoms or detector geometries is crucial for decision making in proton therapy and proton imaging. To this end, several parameterizations of the range-energy relationship exist, with different levels of complexity and accuracy. In this study we compare the accuracy four different parameterizations models: Two analytical models derived from the Bethe eq…
▽ More
An accurate calculation of proton ranges in phantoms or detector geometries is crucial for decision making in proton therapy and proton imaging. To this end, several parameterizations of the range-energy relationship exist, with different levels of complexity and accuracy. In this study we compare the accuracy four different parameterizations models: Two analytical models derived from the Bethe equation, and two different interpolation schemes applied to range-energy tables. In conclusion, a spline interpolation scheme yields the highest reproduction accuracy, while the shape of the energy loss-curve is best reproduced with the differentiated Bragg-Kleeman equation.
△ Less
Submitted 2 August, 2017; v1 submitted 28 April, 2017;
originally announced April 2017.
Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes
Authors:
Helge Egil Seime Pettersen,
Johan Alme,
Aleksandra Biegun,
Anthony van den Brink,
Mamdouh Chaar,
Dominik Fehlker,
Ilker Meric,
Odd Harald Odland,
Thomas Peitzmann,
Elena Rocco,
Hongkai Wang,
Shiming Yang,
Chunhui Zhang,
Dieter Röhrich
Abstract:
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stop** power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stop** power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the…
▽ More
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stop** power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stop** power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stop** power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeteris applied for reconstruction of the tracks and energies of individual high energy protons. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.
△ Less
Submitted 14 June, 2017; v1 submitted 7 November, 2016;
originally announced November 2016.