ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target
Authors:
M. Monterial,
K. T. Schmitt,
C. Prokop,
E. Leal-Cidoncha,
M. Anastasiou,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. H. Dongwi,
N. Fotiades,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
J. King,
J. L. Klay,
J. Latta
, et al. (15 additional authors not shown)
Abstract:
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio betwee…
▽ More
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.
△ Less
Submitted 9 July, 2021; v1 submitted 10 June, 2021;
originally announced June 2021.
-
Measurement of the normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio from threshold to 30 MeV with the fission Time Projection Chamber
Authors:
R. J. Casperson,
D. M. Asner,
J. Baker,
R. G. Baker,
J. S. Barrett,
N. S. Bowden,
C. Brune,
J. Bundgaard,
E. Burgett,
D. A. Cebra,
T. Classen,
M. Cunningham,
J. Deaven,
D. L. Duke,
I. Ferguson,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
S. Grimes,
E. Guardincerri,
U. Hager,
C. Hagmann,
M. Heffner,
D. Hensle,
N. Hertel
, et al. (39 additional authors not shown)
Abstract:
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the…
▽ More
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time-of-flight. The $^{238}$U(n,f)/$^{235}$U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the $^{238}$U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.$β$5 at 14.5 MeV.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Performance of a MICROMEGAS-based TPC in a high-energy neutron beam
Authors:
Lucas Snyder,
Brett Manning,
Nathaniel S. Bowden,
Jeremy Bundgaard,
Robert J. Casperson,
Daniel A. Cebra,
Timothy Classen,
Dana L. Duke,
Joshua Gearhart,
Uwe Greife,
Christian Hagmann,
Michael Heffner,
David Hensle,
Daniel Higgins,
Donald Isenhower,
Jonathan King,
Jennifer L. Klay,
Verena Geppert-Kleinrath,
Walter Loveland,
Joshua A. Magee,
Michael P. Mendenhall,
Samuele Sangiorgio,
Brandon Seilhan,
Kyle T. Schmitt,
Fredrik Tovesson
, et al. (5 additional authors not shown)
Abstract:
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some dr…
▽ More
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. For a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Calibration and performance of the STAR Muon Telescope Detector using cosmic rays
Authors:
C. Yang,
X. J. Huang,
C. M. Du,
B. C. Huang,
Z. Ahammed,
A. Banerjee,
P. Bhattarari,
S. Biswas,
B. Bowen,
J. Butterworth,
M. Calderón de la Barca Sánchez,
H. Carson,
S. Chattopadhyay,
D. Cebra,
H. F. Chen,
J. P. Cheng,
M. Codrington,
G. Eppley,
C. Flores,
F. Geurts,
G. W. Hoffmann,
A. Jentsch,
A. Kesich,
C. Li,
Y. J. Li
, et al. (13 additional authors not shown)
Abstract:
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained…
▽ More
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained were ~100 ps and ~1-2 cm, respectively. These values are comparable to those obtained from cosmic-ray bench tests and test beams.
△ Less
Submitted 5 February, 2014;
originally announced February 2014.
-
The STAR Time Projection Chamber: A Unique Tool for Studying High Multiplicity Events at RHIC
Authors:
M. Anderson,
J. Berkovitz,
W. Betts,
R. Bossingham,
F. Bieser,
R. Brown,
M. Burkes,
M. Calderon de la Barca Sanchez,
D. Cebra,
M. Cherney,
J. Chrin,
W. R. Edwards,
V. Ghazikhanian,
D. Greiner,
M. Gilkes,
D. Hardtke,
G. Harper,
E. Hjort,
H. Huang,
G. Igo,
S. Jacobson,
D. Keane,
S. R. Klein,
G. Koehler,
L. Kotchenda
, et al. (23 additional authors not shown)
Abstract:
The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete coverage around the beam-line, and provides complete tracking for charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass frame. Charged par…
▽ More
The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete coverage around the beam-line, and provides complete tracking for charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass frame. Charged particles with momenta greater than 100 MeV/c are recorded. Multiplicities in excess of 3,000 tracks per event are routinely reconstructed in the software. The TPC measures 4 m in diameter by 4.2 m long, making it the largest TPC in the world.
△ Less
Submitted 26 January, 2003;
originally announced January 2003.
-
The Forward Time Projection Chamber (FTPC) in STAR
Authors:
K. H. Ackermann,
F. Bieser,
F. P. Brady,
D. Cebra,
J. E. Draper,
V. Eckardt,
T. Eggert,
H. Fessler,
K. J. Foley,
V. Ghazikhanian,
T. J. Hallman,
M. Heffner,
H. Huemmler,
J. Klay,
S. R. Klein,
A. Lebedev,
M. J. LeVine,
T. Ljubicic,
G. Lo Curto,
R. S. Longacre,
M. Oldenburg,
HG. Ritter,
J. L. Romero,
N. Schmitz,
A. Schuettauf
, et al. (5 additional authors not shown)
Abstract:
Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |η| < 4.0. For optimal use of the available space and in order to cope with the high track density of central Au+Au collisions at RHIC, a novel design was developed using radial drift in a low diffusion gas. From prototype measurements a 2-track…
▽ More
Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |η| < 4.0. For optimal use of the available space and in order to cope with the high track density of central Au+Au collisions at RHIC, a novel design was developed using radial drift in a low diffusion gas. From prototype measurements a 2-track resolution of 1-2 mm is expected.
△ Less
Submitted 15 November, 2002;
originally announced November 2002.