The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Performance of the LHCb RICH detectors during LHC Run 2
Authors:
R. Calabrese,
M. Fiorini,
E. Luppi,
L. Minzoni,
I. Slazyk,
L. Tomassetti,
M. Bartolini,
R. Cardinale,
F. Fontanelli,
A. Petrolini,
A. Pistone,
M. Calvi,
C. Matteuzzi,
A. Lupato,
G. Simi,
M. Kucharczyk,
B. Malecki,
M. Witek,
S. Benson,
M. Blago,
G. Cavallero,
A. Contu,
C. D'Ambrosio,
C. Frei,
T. Gys
, et al. (57 additional authors not shown)
Abstract:
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
△ Less
Submitted 26 May, 2022;
originally announced May 2022.
-
Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes
Authors:
M. Andreotti,
S. Capelli,
G. Cavallero,
S. Chiozzi,
A. Cotta Ramusino,
C. D'Ambrosio,
M. Fiorini,
E. Franzoso,
C. Frei,
S. Gallorini,
S. Gambetta,
C. Giugliano,
C. Gotti,
T. Gys,
F. Keizer,
M. Maino,
B. Malecki,
L. Minzoni,
S. Mitchell,
I. Neri,
A. Petrolini,
D. Piedigrossi,
G. Robertson,
A. Sergi,
G. Simi
, et al. (4 additional authors not shown)
Abstract:
Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform…
▽ More
Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.
△ Less
Submitted 23 November, 2021; v1 submitted 2 October, 2021;
originally announced October 2021.
-
Test of the photon detection system for the LHCb RICH Upgrade in a charged particle beam
Authors:
M. K. Baszczyk,
M. Benettoni,
R. Calabrese,
R. Cardinale,
P. Carniti,
L. Cassina,
G. Cavallero,
L. Cojocariu,
A. Cotta Ramusino,
C. D'Ambrosio,
P. A. Dorosz,
S. Easo,
S. Eisenhardt,
M. Fiorini,
C. Frei,
S. Gambetta,
V. Gibson,
C. Gotti,
N. Harnew,
J. He,
F. Keizer,
W. Kucewicz,
F. Maciuc,
M. Maino,
R. Malaguti
, et al. (16 additional authors not shown)
Abstract:
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto…
▽ More
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto-electronic chain from the Multi-Anode PMT photosensor to the readout and data acquisition system.
△ Less
Submitted 10 October, 2016;