-
Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics
Authors:
A. Nadolski,
J. D. Vieira,
J. A. Sobrin,
A. M. Kofman,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. R. Cheshire IV,
G. E. Chesmore,
J. F. Cliche,
A. Cukierman,
T. de Haan,
M. Dierickx,
J. Ding,
D. Dutcher,
W. Everett
, et al. (64 additional authors not shown)
Abstract:
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of com…
▽ More
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially-available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97 +/- 2)% transmittance and the lenslet coating sample achieves (94 +/- 3)% transmittance.
△ Less
Submitted 2 March, 2020; v1 submitted 6 December, 2019;
originally announced December 2019.
-
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Authors:
A. J. Anderson,
P. A. R. Ade,
Z. Ahmed,
J. S. Avva,
P. S. Barry,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of the…
▽ More
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-lab characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.
△ Less
Submitted 27 July, 2019;
originally announced July 2019.
-
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Authors:
A. N. Bender,
A. J. Anderson,
J. S. Avva,
P. A. R. Ade,
Z. Ahmed,
P. S. Barry,
R. Basu Thakur,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current…
▽ More
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of $\sim$16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G's measurements of sky power on large angular scales. Measurements also show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Design and characterization of the SPT-3G receiver
Authors:
J. A. Sobrin,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Gallichio,
A. Gilbert,
J. C. Groh,
S. T. Guns,
N. W. Halverson
, et al. (46 additional authors not shown)
Abstract:
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle…
▽ More
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We highlight several key features and design principles of the new receiver, and summarize its performance to date.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Broadband anti-reflective coatings for cosmic microwave background experiments
Authors:
A. Nadolski,
A. M. Kofman,
J. D. Vieira,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Fu,
J. Gallicchio,
A. Gilbert
, et al. (49 additional authors not shown)
Abstract:
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth comp…
▽ More
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to $\sim$700 mm diameter) and lenslets ($\sim$5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetrafluoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Calorimetric observation of single He2* excimers in a 100 mK He bath
Authors:
F. W. Carter,
S. A. Hertel,
M. J. Rooks,
P. V. E. McClintock,
D. N. McKinsey,
D. E. Prober
Abstract:
We report the first calorimetric detection of individual He2* excimers within a bath of superfluid 4He. The detector used in this work is a single superconducting titanium transition edge sensor (TES) with an energy resolution of ~1 eV, immersed directly in the helium bath. He2* excimers are produced in the surrounding bath using an external gamma-ray source. These excimers exist either as short-l…
▽ More
We report the first calorimetric detection of individual He2* excimers within a bath of superfluid 4He. The detector used in this work is a single superconducting titanium transition edge sensor (TES) with an energy resolution of ~1 eV, immersed directly in the helium bath. He2* excimers are produced in the surrounding bath using an external gamma-ray source. These excimers exist either as short-lived singlet or long-lived triplet states. We demonstrate detection of both states: in the singlet case the calorimeter records the absorption of a prompt 15 eV photon, and in the triplet case the calorimeter records a direct interaction of the molecule with the TES surface, which deposits a distinct fraction of the 15 eV, released upon decay, into the surface. We also briefly discuss the detector fabrication and characterization.
△ Less
Submitted 7 July, 2016; v1 submitted 2 May, 2016;
originally announced May 2016.
-
Proposal for a GHz count rate near-IR single-photon detector based on a nanoscale superconducting transition edge sensor
Authors:
Daniel F. Santavicca,
Faustin W. Carter,
Daniel E. Prober
Abstract:
We describe a superconducting transition edge sensor based on a nanoscale niobium detector element. This device is predicted to be capable of energy-resolved near-IR single-photon detection with a GHz count rate. The increased speed and sensitivity of this device compared to traditional transition edge sensors result from the very small electronic heat capacity of the nanoscale detector element. I…
▽ More
We describe a superconducting transition edge sensor based on a nanoscale niobium detector element. This device is predicted to be capable of energy-resolved near-IR single-photon detection with a GHz count rate. The increased speed and sensitivity of this device compared to traditional transition edge sensors result from the very small electronic heat capacity of the nanoscale detector element. In the present work, we calculate the predicted thermal response time and energy resolution. We also discuss approaches for achieving efficient optical coupling to the sub-wavelength detector element using a resonant near-IR antenna.
△ Less
Submitted 21 February, 2012;
originally announced February 2012.