-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
O. Azzolini,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
D. Biare,
M. Biassoni,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Camacho,
A. Caminata
, et al. (140 additional authors not shown)
Abstract:
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure…
▽ More
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.
△ Less
Submitted 1 April, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.
-
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
S. Copello
, et al. (95 additional authors not shown)
Abstract:
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrino…
▽ More
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.
△ Less
Submitted 3 July, 2014;
originally announced July 2014.
-
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (94 additional authors not shown)
Abstract:
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simu…
▽ More
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.
△ Less
Submitted 17 April, 2014;
originally announced April 2014.
-
Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (96 additional authors not shown)
Abstract:
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detecto…
▽ More
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0νββ$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.
△ Less
Submitted 13 February, 2015; v1 submitted 25 February, 2014;
originally announced February 2014.
-
Initial performance of the CUORE-0 experiment
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (88 additional authors not shown)
Abstract:
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-domina…
▽ More
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
△ Less
Submitted 31 July, 2014; v1 submitted 4 February, 2014;
originally announced February 2014.
-
Validation of techniques to mitigate copper surface contamination in CUORE
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (93 additional authors not shown)
Abstract:
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-…
▽ More
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit on the number of background counts in the region of interest is 0.02-0.03 counts/keV/kg/y depending on the adopted mitigation technique.
△ Less
Submitted 4 April, 2013; v1 submitted 3 October, 2012;
originally announced October 2012.
-
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (91 additional authors not shown)
Abstract:
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data…
▽ More
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.
△ Less
Submitted 1 February, 2013; v1 submitted 12 September, 2012;
originally announced September 2012.
-
Signal and noise simulation of CUORE bolometric detectors
Authors:
M. Carrettoni,
M. Vignati
Abstract:
Bolometric detectors are used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. By operating at cryogenic temperatures, they are able to detect particle energies from a few keV up to several MeV, measuring the temperature rise produced by the energy released. This work focusses on the bolometers of the CUORE experimen…
▽ More
Bolometric detectors are used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. By operating at cryogenic temperatures, they are able to detect particle energies from a few keV up to several MeV, measuring the temperature rise produced by the energy released. This work focusses on the bolometers of the CUORE experiment, which are made of TeO$_2$ crystals. The response of these detectors is nonlinear with energy and changes with the operating temperature. The noise depends on the working conditions and significantly affects the energy resolution and the detection performances at low energies. We present a software tool to simulate signal and noise of CUORE-like bolometers, including effects generated by operating temperature drifts, nonlinearities and pileups. The simulations agree well with data.
△ Less
Submitted 18 July, 2011; v1 submitted 20 June, 2011;
originally announced June 2011.
-
Generation of Noise Time Series with arbitrary Power Spectrum
Authors:
M. Carrettoni,
O. Cremonesi
Abstract:
Noise simulation is a very powerful tool in signal analysis hel** to foresee the system performance in real experimental situations. Time series generation is however a hard challenge when a robust model of the noise sources is missing. We present here a simple computational technique which allows the generation of noise samples of fixed length, given a desired power spectrum. A few applications…
▽ More
Noise simulation is a very powerful tool in signal analysis hel** to foresee the system performance in real experimental situations. Time series generation is however a hard challenge when a robust model of the noise sources is missing. We present here a simple computational technique which allows the generation of noise samples of fixed length, given a desired power spectrum. A few applications of the method are also discussed.
△ Less
Submitted 11 November, 2010; v1 submitted 16 June, 2010;
originally announced June 2010.
-
Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay
Authors:
C. Arnaboldi,
C. Brofferio,
A. Bryant,
C. Bucci,
L. Canonica,
S. Capelli,
M. Carrettoni,
M. Clemenza,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
E. Fiorini,
Z. Ge,
A. Giachero,
L. Gironi,
A. Giuliani,
P. Gorla,
E. Guardincerri,
R. Kadel,
K. Kazkaz,
L. Kogler,
Y. Kolomensky,
J. Larsen,
M. Laubenstein,
Y. Li
, et al. (21 additional authors not shown)
Abstract:
High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consuma…
▽ More
High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consumables, ancillaries and intermediary products used for TeO2 crystals production are reported. Production and certification protocols are presented and resulting ready-to-use TeO2 crystals are described.
△ Less
Submitted 20 May, 2010;
originally announced May 2010.