Construction of Precision sMDT Detector for ATLAS Muon Spectrometer Upgrade
Authors:
D. Amidei,
N. Anderson,
A. Chen,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
Y. Guo,
J. Li,
X. Meng,
K. Nelson,
V. Pillsbury,
E. Salzer,
T. Schwarz,
L. Simpson,
Z. Wang,
C. Weaverdyck,
C. Wei,
Z. Yang,
M. Yuan,
B. Zhou,
J. Zhu
Abstract:
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms f…
▽ More
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 +- 7 microns with an average detection efficiency above 99 %. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Construction and testing of sMDT tubes at the University of Michigan for the ATLAS Muon Spectrometer upgrade
Authors:
C. Wei,
A. Chen,
D. Amidei,
N. Anderson,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
J. Li,
P. Lugato,
J. Minnella,
S. Moskaitis,
K. Nelson,
V. Pillsbury,
E. Salzer,
L. Simpson,
Z. C. Wang,
Z. R. Wang,
C. Weaverdyck,
Z. Yang,
B. Zhou
Abstract:
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in d…
▽ More
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in detail. More than 99% of the tubes meet the tube QA/QC specifications based on 2100 tubes built at UM. The UM test stations are also used for QA/QC testing on the tubes constructed at Michigan State University. These tubes are being used to construct the sMDT chambers which will replace the current MDT chambers of the barrel inner station of the Muon Spectrometer.
△ Less
Submitted 8 September, 2022;
originally announced September 2022.
-
Model of ionic currents through microtubule nanopores and the lumen
Authors:
Holly Freedman,
Vahid Rezania,
Avner Priel,
Eric Carpenter,
Sergei Y. Noskovd,
Jack A. Tuszynski
Abstract:
It has been suggested that microtubules and other cytoskeletal filaments may act as electrical transmission lines. An electrical circuit model of the microtubule is constructed incorporating features of its cylindrical structure with nanopores in its walls. This model is used to study how ionic conductance along the lumen is affected by flux through the nanopores when an external potential is ap…
▽ More
It has been suggested that microtubules and other cytoskeletal filaments may act as electrical transmission lines. An electrical circuit model of the microtubule is constructed incorporating features of its cylindrical structure with nanopores in its walls. This model is used to study how ionic conductance along the lumen is affected by flux through the nanopores when an external potential is applied across its two ends. Based on the results of Brownian dynamics simulations, the nanopores were found to have asymmetric inner and outer conductances, manifested as nonlinear IV curves. Our simulations indicate that a combination of this asymmetry and an internal voltage source arising from the motion of the C-terminal tails causes a net current to be pumped across the microtubule wall and propagate down the microtubule through the lumen. This effect is demonstrated to enhance and add directly to the longitudinal current through the lumen resulting from an external voltage source, and could be significant in amplifying low-intensity endogenous currents within the cellular environment or as a nano-bioelectronic device.
△ Less
Submitted 8 December, 2009; v1 submitted 10 August, 2009;
originally announced August 2009.