Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence
Authors:
A. Bornheim,
W. Lustermann,
K. Stachon,
G. Reales Gutiérrez,
A. Benaglia,
F. De Guio,
A. Ghezzi,
M. T. Lucchini,
M. Malberti,
S. Palluotto,
T. Tabarelli de Fatis,
M. Benettoni,
R. Carlin,
M. Tosi,
R. Rossin,
P. Meridiani,
R. Paramatti,
F. Santanastasio,
J. C. Silva,
J. Varela,
A. Heering,
A. Karneyeu,
Y. Musienko,
M. Wayne,
T. Anderson
, et al. (5 additional authors not shown)
Abstract:
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about…
▽ More
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.
△ Less
Submitted 23 August, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.
-
The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
L. Barcellan,
C. Baldanza,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
A. Bergnoli,
L. C. Blanco Ramos,
L. Borgonovi,
A. Bragagnolo,
V. Cafaro,
A. Calderon,
E. Calvo,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo,
J. M. Cela Ruiz
, et al. (121 additional authors not shown)
Abstract:
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the s…
▽ More
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98\% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
J. M. Barcala,
L. Barcellan,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
L. C. Blanco Ramos,
A. Boletti,
A. Bragagnolo,
J. A. Brochero Cifuentes,
V. Cafaro,
A. Calderon,
E. Calvo,
A. Cappati,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo
, et al. (118 additional authors not shown)
Abstract:
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irrad…
▽ More
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
The design and performance of the ZEUS Micro Vertex detector
Authors:
A. Polini,
I. Brock,
S. Goers,
A. Kappes,
U. F. Katz,
E. Hilger,
J. Rautenberg,
A. Weber,
A. Mastroberardino,
E. Tassi,
V. Adler,
L. A. T. Bauerdick,
I. Bloch,
T. Haas,
U. Klein,
U. Koetz,
G. Kramberger,
E. Lobodzinska,
R. Mankel,
J. Ng,
D. Notz,
M. C. Petrucci,
B. Surrow,
G. Watt,
C. Youngman
, et al. (57 additional authors not shown)
Abstract:
In order to extend the tracking acceptance, to improve the primary and secondary vertex reconstruction and thus enhancing the tagging capabilities for short lived particles, the ZEUS experiment at the HERA Collider at DESY installed a silicon strip vertex detector. The barrel part of the detector is a 63 cm long cylinder with silicon sensors arranged around an elliptical beampipe. The forward pa…
▽ More
In order to extend the tracking acceptance, to improve the primary and secondary vertex reconstruction and thus enhancing the tagging capabilities for short lived particles, the ZEUS experiment at the HERA Collider at DESY installed a silicon strip vertex detector. The barrel part of the detector is a 63 cm long cylinder with silicon sensors arranged around an elliptical beampipe. The forward part consists of four circular shaped disks. In total just over 200k channels are read out using $2.9 {\rm m^2}$ of silicon. In this report a detailed overview of the design and construction of the detector is given and the performance of the completed system is reviewed.
△ Less
Submitted 21 August, 2007;
originally announced August 2007.