-
HTESP (High-throughput electronic structure package): a Package for the high-throughput $ab$ $initio$ calculations
Authors:
Niraj K. Nepal,
Paul C. Canfield,
Lin-Lin Wang
Abstract:
High-throughput $ab$ $initio$ calculations are the indispensable parts of data-driven discovery of new materials with desirable properties, as reflected in the establishment of several online material databases. The accumulation of extensive theoretical data through computations enables data-driven discovery by constructing machine learning and artificial intelligence models to predict novel compo…
▽ More
High-throughput $ab$ $initio$ calculations are the indispensable parts of data-driven discovery of new materials with desirable properties, as reflected in the establishment of several online material databases. The accumulation of extensive theoretical data through computations enables data-driven discovery by constructing machine learning and artificial intelligence models to predict novel compounds and forecast their properties. Efficient usage and extraction of data from these existing online material databases can accelerate the next stage materials discovery that targets different and more advanced properties, such as electron-phonon coupling for phonon-mediated superconductivity. However, extracting data from these databases, generating tailored input files for different $ab$ $initio$ calculations, performing such calculations, and analyzing new results can be demanding tasks. Here, we introduce a software package named "HTESP" (High-Throughput Electronic Structure Package) written in Python and Bash languages, which automates the entire workflow including data extraction, input file generation, calculation submission, result collection and plotting. Our HTESP will help speed up future computational materials discovery processes.
△ Less
Submitted 17 June, 2024; v1 submitted 6 June, 2024;
originally announced June 2024.
-
Simplified feedback control system for Scanning Tunneling Microscopy
Authors:
Francisco Martín-Vega,
Víctor Barrena,
Raquel Sánchez-Barquilla,
Marta Fernández-Lomana,
José Benito Llorens,
Beilun Wu,
Antón Fente,
David Perconte Duplain,
Ignacio Horcas,
Raquel López,
Javier Blanco,
Juan Antonio Higuera,
Samuel Mañas-Valero,
Na Hyun Jo,
Juan Schmidt,
Paul C. Canfield,
Gabino Rubio-Bollinger,
José Gabriel Rodrigo,
Edwin Herrera,
Isabel Guillamón,
Hermann Suderow
Abstract:
A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between tip and sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on…
▽ More
A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between tip and sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here we discuss another approach, using a computer and data acquisition through the USB port. We find that it allows succesful ultra low noise studies of surfaces at cryogenic temperatures. We show results on different compounds, a type II Weyl semimetal (WTe$_2$), a quasi two-dimensional dichalcogenide superconductor (2H-NbSe$_2$), a magnetic Weyl semimetal (Co$_3$Sn$_2$S$_2$) and an iron pnictide superconductor (FeSe).
△ Less
Submitted 27 April, 2022;
originally announced April 2022.
-
Low temperature competing magnetic energy scales in the topological ferrimagnet TbMn6Sn6
Authors:
S. X. M. Riberolles,
Tyler J. Slade,
D. L. Abernathy,
G. E. Granroth,
Bing Li,
Y. Lee,
P. C. Canfield,
B. G. Ueland,
Liqin Ke,
R. J. McQueeney
Abstract:
TbMn6Sn6 is a metallic ferrimagnet displaying signatures of both topological electrons and topological magnons arising from ferromagnetism and spin-orbit coupling within its Mn kagome layers. Inelastic neutron scattering measurements find strong ferromagnetic (FM) interactions within the Mn kagome layer and reveal a magnetic bandwidth of ~230 meV. The low-energy magnetic excitations are characteri…
▽ More
TbMn6Sn6 is a metallic ferrimagnet displaying signatures of both topological electrons and topological magnons arising from ferromagnetism and spin-orbit coupling within its Mn kagome layers. Inelastic neutron scattering measurements find strong ferromagnetic (FM) interactions within the Mn kagome layer and reveal a magnetic bandwidth of ~230 meV. The low-energy magnetic excitations are characterized by strong FM Mn-Mn and antiferromagnetic (AFM) Mn-Tb interlayer magnetic couplings. We observe weaker, competing long-range FM and AFM Mn-Mn interlayer interactions similar to those driving helical magnetism in the YMn6Sn6 system. Combined with density-functional theory calculations, we find that competing Mn-Mn interlayer magnetic interactions occur in all RMn6Sn6 compounds with R= Y, Gd-Lu, resulting in magnetic instabilities and tunability when Mn-R interactions are weak. In the case of TbMn6Sn6, strong AFM Mn-Tb coupling ensures a highly stable three-dimensional ferrimagnetic network.
△ Less
Submitted 24 June, 2022; v1 submitted 27 October, 2021;
originally announced October 2021.
-
Nuclear Magnetic Resonance Probe Head Design for Precision Strain Control
Authors:
T. Kissikov,
R. Sarkar,
B. T. Bush,
M. Lawson,
P. C. Canfield,
N. J. Curro
Abstract:
We present the design and construction of an NMR probe to investigate single crystals under strain at cryogenic temperatures. The probe head incorporates a piezoelectric-based apparatus from Razorbill Instruments that enables both compressive and tensile strain tuning up to strain values on the order of 0.3% with a precision of 0.001%. $^{75}$As NMR in BaFe$_2$As$_2$ reveals large changes to the e…
▽ More
We present the design and construction of an NMR probe to investigate single crystals under strain at cryogenic temperatures. The probe head incorporates a piezoelectric-based apparatus from Razorbill Instruments that enables both compressive and tensile strain tuning up to strain values on the order of 0.3% with a precision of 0.001%. $^{75}$As NMR in BaFe$_2$As$_2$ reveals large changes to the electric field gradient, and indicates that the strain is homogeneous to within 16% over the volume of the NMR coil.
△ Less
Submitted 24 August, 2017;
originally announced August 2017.
-
A single-solenoid pulsed-magnet system for single-crystal scattering studies
Authors:
Zahirul Islam,
Dana Capatina,
Jacob P. C. Ruff,
Ritesh K. Das,
Emil Trakhtenberg,
Hiroyuki Nojiri,
Yasuo Narumi,
Ulrich Welp,
Paul C. Canfield
Abstract:
We present a pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies with the magnetic field applied on or close to the scattering plane. The apparatus consists of a single large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic…
▽ More
We present a pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies with the magnetic field applied on or close to the scattering plane. The apparatus consists of a single large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic fields close to $\sim 30$ T with a zero-to-peak-field rise time of $\sim$2.9 ms are generated by discharging a 40 kJ capacitor bank into the magnet coil. The unique characteristic of this instrument is the preservation of maximum scattering angle ($\sim 23.6^\circ$) on the entrance and exit sides of the magnet bore by virtue of a novel double-funnel insert. This instrument will facilitate x-ray diffraction and spectroscopic studies that are impractical, if not impossible, to perform using split-pair and narrow-opening solenoid magnets, and offers a practical solution for preserving optical access in future higher-field pulsed magnets.
△ Less
Submitted 7 February, 2012; v1 submitted 30 September, 2011;
originally announced September 2011.
-
Millimeter-wave study of London penetration depth temperature dependence in Ba(Fe0.926Co0.074)2As2 single crystal
Authors:
A. A. Barannik,
N. T. Cherpak,
N. Ni,
M. A. Tanatar,
S. A. Vitusevich,
V. N. Skresanov,
P. C. Canfield,
R. Prozorov,
V. V. Glamazdin,
K. I. Torokhtii
Abstract:
In-plane surface Ka-band microwave impedance of optimally doped single crystals of the Fe-based superconductor Ba(Fe0.926Co0.074)2As2 (Tc= 22.8K) was measured. Sensitive sapphire disk quasi-optical resonator with high-Tc cuprate conducting endplates was developed specially for Fe-pnictide superconductors. It allowed finding temperature variation of London penetration depth in a form of power law,…
▽ More
In-plane surface Ka-band microwave impedance of optimally doped single crystals of the Fe-based superconductor Ba(Fe0.926Co0.074)2As2 (Tc= 22.8K) was measured. Sensitive sapphire disk quasi-optical resonator with high-Tc cuprate conducting endplates was developed specially for Fe-pnictide superconductors. It allowed finding temperature variation of London penetration depth in a form of power law, namely Δλ(T)~ Tn with n = 2.8 from low temperatures up to at least 0.6Tc consisted with radio-frequency measurements. This exponent points towards nodeless state with pairbreaking scattering, which can support one of the extended s-pairing symmetries. The dependence λ(T) at low temperatures is well described by one superconducting small-gap (Δ\cong 0.75 in kTc units, where k is Boltzman coefficient) exponential dependence.
△ Less
Submitted 30 June, 2011;
originally announced June 2011.
-
Experimental Setup for the Measurement of the Thermoelectric Power in Zero and Applied Magnetic Field
Authors:
Eundeok Mun,
Sergey L. Bud'ko,
Milton S. Torikachvili,
Paul C. Canfield
Abstract:
An experimental setup was developed for the measurement of the thermoelectric power (TEP, Seebeck coefficient) in the temperature range from 2 to 350 K and magnetic fields up to 140 kOe. The system was built to fit in a commercial cryostat and is versatile, accurate and automated; using two heaters and two thermometers increases the accuracy of the TEP measurement. High density data of temperatu…
▽ More
An experimental setup was developed for the measurement of the thermoelectric power (TEP, Seebeck coefficient) in the temperature range from 2 to 350 K and magnetic fields up to 140 kOe. The system was built to fit in a commercial cryostat and is versatile, accurate and automated; using two heaters and two thermometers increases the accuracy of the TEP measurement. High density data of temperature sweeps from 2 to 350 K can be acquired in under 16 hours and high density data of isothermal field sweeps from 0 to 140 kOe can be obtained in under 2 hours. Calibrations for the system have been performed on a platinum wire and Bi$_{2}$Sr$_{2}$CaCu$_{2}$O$_{8+δ}$ high $T_{c}$ superconductors. The measured TEP of phosphor-bronze (voltage lead wire) turns to be very small, where the absolute TEP value of phosphor-bronze wire is much less than 0.5 $μ$V/K below 80 K. For copper and platinum wires measured against to the phosphor-bronze wire, the agreement between measured results and the literature data is good. To demonstrate the applied magnetic field response of the system, we report measurements of the TEP on single crystal samples of LaAgSb$_{2}$ and CeAgSb$_{2}$ in fields up to 140 kOe.
△ Less
Submitted 3 March, 2010;
originally announced March 2010.
-
A small sealed Ta crucible for thermal analysis of volatile metallic samples
Authors:
Y. Janssen,
M. Angst,
K. W. Dennis,
P. C. Canfield,
R. W. McCallum
Abstract:
Differential thermal analysis on metallic alloys containing volatile elements can be highly problematic. Here we show how measurements can be performed in commercial, small-sample, equipment without modification. This is achieved by using a sealed Ta crucible, easily fabricated from Ta tubing and sealed in a standard arc furnace. The crucible performance is demonstrated by measurements on a mixt…
▽ More
Differential thermal analysis on metallic alloys containing volatile elements can be highly problematic. Here we show how measurements can be performed in commercial, small-sample, equipment without modification. This is achieved by using a sealed Ta crucible, easily fabricated from Ta tubing and sealed in a standard arc furnace. The crucible performance is demonstrated by measurements on a mixture of Mg and MgB$_2$, after heating up to 1470$^{\circ}{\rm C}$. We also show data, measured on an alloy with composition Gd$_{40}$Mg$_{60}$, that clearly shows both the liquidus and a peritectic, and is consistent with published phase diagram data.
△ Less
Submitted 2 November, 2005;
originally announced November 2005.