-
Pore size estimation in axon-mimicking microfibres with diffusion-relaxation MRI
Authors:
Erick J. Canales-Rodríguez,
Marco Pizzolato,
Feng-Lei Zhou,
Muhamed Barakovic,
Jean-Philippe Thiran,
Derek K. Jones,
Geoffrey J. M. Parker,
Tim B. Dyrby
Abstract:
Purpose: This study aims to evaluate two distinct approaches for fibre radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfibre phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. Theory and Methods: A general diffusion-relaxation theoretical model for the spherical mean sig…
▽ More
Purpose: This study aims to evaluate two distinct approaches for fibre radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfibre phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. Theory and Methods: A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from Scanning Electron Microscope images. Results: Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, though some discrepancies were observed. The spherical mean power-law method overestimated fibre radii. Conversely, the T2-based method exhibited higher sensitivity to smaller fibre radii but faced limitations in accurately estimating the radius in one particular phantom, possibly due to material-specific relaxation changes. Conclusion: The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibres. The T2-based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fibre radius estimation, highlights the advantages and limitations of both methods and provides datasets for reproducible research.
△ Less
Submitted 21 December, 2023; v1 submitted 5 November, 2023;
originally announced November 2023.
-
Estimating axon radius using diffusion-relaxation MRI: calibrating a surface-based relaxation model with histology
Authors:
Muhamed Barakovic,
Marco Pizzolato,
Chantal M. W. Tax,
Umesh Rudrapatna,
Stefano Magon,
Tim B. Dyrby,
Cristina Granziera,
Jean-Philippe Thiran,
Derek K. Jones,
Erick J. Canales-Rodríguez
Abstract:
Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit o…
▽ More
Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit of dMRI signals even when using the most advanced human MRI scanners. Therefore, new MRI methods that are sensitive to small axon radii are needed. In this proof-of-concept investigation, we examine whether a surface-based axonal relaxation process could mediate a relationship between intra-axonal T2 and T1 times and inner axon radius, as measured using postmortem histology. A unique in vivo human diffusion-T1-T2 relaxation dataset was acquired on a 3T MRI scanner with ultra-strong diffusion gradients, using a strong diffusion-weighting (i.e., b = 6,000 s/mm$^2$) and multiple inversion and echo times. A second reduced diffusion-T2 dataset was collected at various echo times to evaluate the model further. The intra-axonal relaxation times were estimated by fitting a diffusion-relaxation model to the orientation-averaged spherical mean signals. Our analysis revealed that the proposed surface-based relaxation model effectively explains the relationship between the estimated relaxation times and the histological axon radius measured in various corpus callosum regions. Using these histological values, we developed a novel calibration approach to predict axon radius in other areas of the corpus callosum. Notably, the predicted radii and those determined from histological measurements were in close agreement.
△ Less
Submitted 13 August, 2023; v1 submitted 18 April, 2023;
originally announced April 2023.
-
Cellular EXchange Imaging (CEXI): Evaluation of a diffusion model including water exchange in cells using numerical phantoms of permeable spheres
Authors:
Rémy Gardier,
Juan Luis Villarreal Haro,
Erick J. Canales-Rodriguez,
Ileana O. Jelescu,
Gabriel Girard,
Jonathan Rafael-Patino,
Jean-Philippe Thiran
Abstract:
Purpose: Biophysical models of diffusion MRI have been developed to characterize microstructure in various tissues, but existing models are not suitable for tissue composed of permeable spherical cells. In this study we introduce Cellular Exchange Imaging (CEXI), a model tailored for permeable spherical cells, and compares its performance to a related Ball \& Sphere (BS) model that neglects permea…
▽ More
Purpose: Biophysical models of diffusion MRI have been developed to characterize microstructure in various tissues, but existing models are not suitable for tissue composed of permeable spherical cells. In this study we introduce Cellular Exchange Imaging (CEXI), a model tailored for permeable spherical cells, and compares its performance to a related Ball \& Sphere (BS) model that neglects permeability. Methods: We generated DW-MRI signals using Monte-Carlo simulations with a PGSE sequence in numerical substrates made of spherical cells and their extracellular space for a range of membrane permeability. From these signals, the properties of the substrates were inferred using both BS and CEXI models. Results: CEXI outperformed the impermeable model by providing more stable estimates cell size and intracellular volume fraction that were diffusion time-independent. Notably, CEXI accurately estimated the exchange time for low to moderate permeability levels previously reported in other studies ($κ<25μm/s$). However, in highly permeable substrates ($κ=50μm/s$), the estimated parameters were less stable, particularly the diffusion coefficients. Conclusion: This study highlights the importance of modeling the exchange time to accurately quantify microstructure properties in permeable cellular substrates. Future studies should evaluate CEXI in clinical applications such as lymph nodes, investigate exchange time as a potential biomarker of tumor severity, and develop more appropriate tissue models that account for anisotropic diffusion and highly permeable membranes.
△ Less
Submitted 7 June, 2023; v1 submitted 28 March, 2023;
originally announced March 2023.
-
Microstructure estimation from diffusion-MRI: Compartmentalized models in permeable cellular tissue
Authors:
Rémy Gardier,
Juan Luis Villarreal Haro,
Erick J Canales-Rodrıguez,
Ileana O. Jelescu,
Gabriel Girard,
Jonathan Rafael-Patino,
Jean-Philippe Thiran
Abstract:
Diffusion-weighted magnetic resonance imaging (DW-MRI) is used to characterize brain tissue microstructure employing tissue-specific biophysical models. A current limitation, however, is that most of the proposed models are based on the assumption of negligible water exchange between the intra- and extracellular compartments, which might not be valid in various brain tissues, including unmyelinate…
▽ More
Diffusion-weighted magnetic resonance imaging (DW-MRI) is used to characterize brain tissue microstructure employing tissue-specific biophysical models. A current limitation, however, is that most of the proposed models are based on the assumption of negligible water exchange between the intra- and extracellular compartments, which might not be valid in various brain tissues, including unmyelinated axons, gray matter, and tumors. The purpose of this work is to quantify the effect of membrane permeability on the estimates of two popular models neglecting exchange, and compare their performance with a model including exchange. To this aim, DW-MRI experiments were performed in controlled environments with Monte-Carlo simulations. The DW-MRI signals were generated in numerical substrates mimicking biological tissue made of spherical cells with permeable membranes like cancerous tissue or the brain gray matter. From these signals, the substrates properties were estimated using SANDI and VERDICT, the two compartment-based models neglecting exchange, and CEXI, a new model which includes exchange. Our results show that, in cellular permeable tissue, the model with exchange outperformed models without exchange in the estimation of the tissue properties by providing more stable estimates of cell size, intracellular volume fraction and extracellular diffusion coefficient. Moreover, the model with exchange estimated accurately the exchange time in the range of permeability reported for cellular tissue. Finally, the simulations performed in this work showed that the exchange between the intracellular and the extracellular space cannot be neglected in permeable tissue with a conventional PGSE sequence, to obtain accurate estimates. Consequently, existing compartmentalized models of impermeable tissue cannot be used for microstructure estimation of cellular permeable tissue.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Slice estimation in diffusion MRI of neonatal and fetal brains in image and spherical harmonics domains using autoencoders
Authors:
Hamza Kebiri,
Gabriel Girard,
Yasser Aleman-Gomez,
Thomas Yu,
Andras Jakab,
Erick Jorge Canales-Rodriguez,
Meritxell Bach Cuadra
Abstract:
Diffusion MRI (dMRI) of the develo** brain can provide valuable insights into the white matter development. However, slice thickness in fetal dMRI is typically high (i.e., 3-5 mm) to freeze the in-plane motion, which reduces the sensitivity of the dMRI signal to the underlying anatomy. In this study, we aim at overcoming this problem by using autoencoders to learn unsupervised efficient represen…
▽ More
Diffusion MRI (dMRI) of the develo** brain can provide valuable insights into the white matter development. However, slice thickness in fetal dMRI is typically high (i.e., 3-5 mm) to freeze the in-plane motion, which reduces the sensitivity of the dMRI signal to the underlying anatomy. In this study, we aim at overcoming this problem by using autoencoders to learn unsupervised efficient representations of brain slices in a latent space, using raw dMRI signals and their spherical harmonics (SH) representation. We first learn and quantitatively validate the autoencoders on the develo** Human Connectome Project pre-term newborn data, and further test the method on fetal data. Our results show that the autoencoder in the signal domain better synthesized the raw signal. Interestingly, the fractional anisotropy and, to a lesser extent, the mean diffusivity, are best recovered in missing slices by using the autoencoder trained with SH coefficients. A comparison was performed with the same maps reconstructed using an autoencoder trained with raw signals, as well as conventional interpolation methods of raw signals and SH coefficients. From these results, we conclude that the recovery of missing/corrupted slices should be performed in the signal domain if the raw signal is aimed to be recovered, and in the SH domain if diffusion tensor properties (i.e., fractional anisotropy) are targeted. Notably, the trained autoencoders were able to generalize to fetal dMRI data acquired using a much smaller number of diffusion gradients and a lower b-value, where we qualitatively show the consistency of the estimated diffusion tensor maps.
△ Less
Submitted 28 August, 2022;
originally announced August 2022.
-
Axial and radial axonal diffusivities from single encoding strongly diffusion-weighted MRI
Authors:
Marco Pizzolato,
Erick Jorge Canales-Rodríguez,
Mariam Andersson,
Tim B. Dyrby
Abstract:
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the…
▽ More
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the sum of the contributions from axons. At the same time, spherical averaging leads to a major simplification of the modeling by removing the need to explicitly account for the unknown orientation distribution of axons. However, the spherically averaged signal acquired at strong diffusion weightings is not sensitive to the axial diffusivity, which cannot therefore be estimated. After revising existing theory, we introduce a new general method for the estimation of both axonal diffusivities at strong diffusion weightings based on zonal harmonics modeling. We additionally show how this could lead to estimates that are free from partial volume bias with, for instance, gray matter. We test the method on publicly available data from the MGH Adult Diffusion Human Connectome project dataset. We report reference values of axonal diffusivities based on 34 subjects, and derive estimates of axonal radii. We address the estimation problem also from the angle of the required data preprocessing, the presence of biases related to modeling assumptions, current limitations, and future possibilities.
△ Less
Submitted 6 July, 2022;
originally announced July 2022.
-
Validation and Generalizability of Self-Supervised Image Reconstruction Methods for Undersampled MRI
Authors:
Thomas Yu,
Tom Hilbert,
Gian Franco Piredda,
Arun Joseph,
Gabriele Bonanno,
Salim Zenkhri,
Patrick Omoumi,
Meritxell Bach Cuadra,
Erick Jorge Canales-Rodríguez,
Tobias Kober,
Jean-Philippe Thiran
Abstract:
Deep learning methods have become the state of the art for undersampled MR reconstruction. Particularly for cases where it is infeasible or impossible for ground truth, fully sampled data to be acquired, self-supervised machine learning methods for reconstruction are becoming increasingly used. However potential issues in the validation of such methods, as well as their generalizability, remain un…
▽ More
Deep learning methods have become the state of the art for undersampled MR reconstruction. Particularly for cases where it is infeasible or impossible for ground truth, fully sampled data to be acquired, self-supervised machine learning methods for reconstruction are becoming increasingly used. However potential issues in the validation of such methods, as well as their generalizability, remain underexplored. In this paper, we investigate important aspects of the validation of self-supervised algorithms for reconstruction of undersampled MR images: quantitative evaluation of prospective reconstructions, potential differences between prospective and retrospective reconstructions, suitability of commonly used quantitative metrics, and generalizability. Two self-supervised algorithms based on self-supervised denoising and the deep image prior were investigated. These methods are compared to a least squares fitting and a compressed sensing reconstruction using in-vivo and phantom data. Their generalizability was tested with prospectively under-sampled data from experimental conditions different to the training. We show that prospective reconstructions can exhibit significant distortion relative to retrospective reconstructions/ground truth. Furthermore, pixel-wise quantitative metrics may not capture differences in perceptual quality accurately, in contrast to a perceptual metric. In addition, all methods showed potential for generalization; however, generalizability is more affected by changes in anatomy/contrast than other changes. We further showed that no-reference image metrics correspond well with human rating of image quality for studying generalizability. Finally, we showed that a well-tuned compressed sensing reconstruction and learned denoising perform similarly on all data.
△ Less
Submitted 12 September, 2022; v1 submitted 29 January, 2022;
originally announced January 2022.
-
Robust Monte-Carlo Simulations in Diffusion-MRI: Effect of the substrate complexity and parameter choice on the reproducibility of results
Authors:
Jonathan Rafael-Patino,
David Romascano,
Alonso Ramirez-Manzanares,
Erick Jorge Canales-Rodríguez,
Gabriel Girard,
Jean-Philippe Thiran
Abstract:
Monte-Carlo Diffusion Simulations (MCDS) have been used extensively as a ground truth tool for the validation of microstructure models for Diffusion-Weighted MRI. However, methodological pitfalls in the design of the biomimicking geometrical configurations and the simulation parameters can lead to approximation biases. Such pitfalls affect the reliability of the estimated signal, as well as its va…
▽ More
Monte-Carlo Diffusion Simulations (MCDS) have been used extensively as a ground truth tool for the validation of microstructure models for Diffusion-Weighted MRI. However, methodological pitfalls in the design of the biomimicking geometrical configurations and the simulation parameters can lead to approximation biases. Such pitfalls affect the reliability of the estimated signal, as well as its validity and reproducibility as ground truth data. In this work, we first present a set of experiments in order to study three critical pitfalls encountered in the design of MCDS in the literature, namely, the number of simulated particles and time steps, simplifications in the intra-axonal substrate representation, and the impact of the substrate's size on the signal stemming from the extra-axonal space. The results obtained show important changes in the simulated signals and the recovered microstructure features when changes in those parameters are introduced. Thereupon, driven by our findings from the first studies, we outline a general framework able to generate complex substrates. We show the framework's capability to overcome the aforementioned simplifications by generating a complex crossing substrate, which preserves the volume in the crossing area and achieves a high packing density. The results presented in this work,along with the simulator developed, pave the way towards more realistic and reproducible Monte-Carlo simulations for Diffusion-Weighted MRI.
△ Less
Submitted 13 November, 2019; v1 submitted 29 August, 2019;
originally announced August 2019.
-
Spherical deconvolution of multichannel diffusion MRI data with non-Gaussian noise models and spatial regularization
Authors:
Erick J. Canales-Rodríguez,
Alessandro Daducci,
Stamatios N. Sotiropoulos,
Emmanuel Caruyer,
Santiago Aja-Fernández,
Joaquim Radua,
Jesús María Yurramendi Mendizabal,
Yasser Iturria-Medina,
Lester Melie-García,
Yasser Alemán-Gómez,
Jean-Philippe Thiran,
Salvador Sarró,
Edith Pomarol-Clotet,
Raymond Salvador
Abstract:
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods fo…
▽ More
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods for multichannel signal combination lead to Rician and noncentral Chi noise distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to Rician and noncentral Chi likelihood models. To quantify the benefits of using proper noise models, RUMBA-SD was compared with dRL-SD, a well-established method based on the RL algorithm for Gaussian noise. Another aim of the study was to quantify the impact of including a total variation (TV) spatial regularization term in the estimation framework. To do this, we developed TV spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The evaluation was performed by comparing various quality metrics on 132 three-dimensional synthetic phantoms involving different inter-fiber angles and volume fractions, which were contaminated with noise mimicking patterns generated by data processing in multichannel scanners. The results demonstrate that the inclusion of proper likelihood models leads to an increased ability to resolve fiber crossings with smaller inter-fiber angles and to better detect non-dominant fibers. The inclusion of TV regularization dramatically improved the resolution power of both techniques. The above findings were also verified in brain data.
△ Less
Submitted 8 October, 2015; v1 submitted 23 October, 2014;
originally announced October 2014.