AGATA - Advanced Gamma Tracking Array
Authors:
S. Akkoyun,
A. Algora,
B. Alikhani,
F. Ameil,
G. de Angelis,
L. Arnold,
A. Astier,
A. AtaƧ,
Y. Aubert,
C. Aufranc,
A. Austin,
S. Aydin,
F. Azaiez,
S. Badoer,
D. L. Balabanski,
D. Barrientos,
G. Baulieu,
R. Baumann,
D. Bazzacco,
F. A. Beck,
T. Beck,
P. Bednarczyk,
M. Bellato,
M. A. Bentley,
G. Benzoni
, et al. (329 additional authors not shown)
Abstract:
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the…
▽ More
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realization of gamma-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly-segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterization of the crystals was measured and compared with detector-response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximize its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer.
△ Less
Submitted 17 September, 2012; v1 submitted 24 November, 2011;
originally announced November 2011.
Lock-in detection using a cryogenic low noise looped current preamplifier for the readout of resistive bolometers
Authors:
D. Yvon,
V. Sushkov,
R. Bernard,
J. L. Bret,
B. Cahan,
O. Cloue,
O. Maillard,
B. Mazeau,
J. P. Passerieux,
B. Paul,
C. Veyssiere
Abstract:
We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by the readout time constant due to the thermometer resistance and the input capacitance. Using cold JFETs, this preamplifier board is shown to have very low no…
▽ More
We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by the readout time constant due to the thermometer resistance and the input capacitance. Using cold JFETs, this preamplifier board is shown to have very low noise: the Johnson noise of the source resistor (1 fA/Hz1/2) dominated in our noise measurements. We also implemented a lock-in chain using this preamplifier. Because of fast risetime, compensation of the phase shift may be unnecessary. If implemented, no tuning is necessary when the sensor impedance changes. Transients are very short, and thus low-passing or sampling of the signal is simplified. In case of spurious noise, the modulation frequency can be chosen in a much wider frequency range, without requiring a new calibration of the apparatus.
△ Less
Submitted 20 June, 2001; v1 submitted 17 February, 1999;
originally announced February 1999.