Performance in beam tests of Carbon-enriched irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector
Authors:
S. Ali,
H. Arnold,
S. L. Auwens,
L. A. Beresford,
D. E. Boumediene,
A. M. Burger,
L. Cadamuro,
L. Castillo García,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
D. Dannheim,
V. Dao,
A. Gabrielli,
Y. El Ghazali,
H. El Jarrari,
V. Gautam,
S. Grinstein,
J. Guimarães da Costa,
S. Guindon,
X. Jia,
G. Kramberger,
Y. Liu,
K. Ma,
N. Makovec,
S. Manzoni
, et al. (12 additional authors not shown)
Abstract:
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation env…
▽ More
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation environment, LGADs have been optimized by adding carbon in the gain layer, thus reducing the acceptor removal rate after irradiation. Performances of several carbon-enriched LGAD sensors from different vendors, and irradiated with high fluences of 1.5 and 2.5 x 10^15 neq/cm2, have been measured in beam test campaigns during the years 2021 and 2022 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few um. Collected charge, time resolution and hit efficiency measurements are presented. In addition, the efficiency uniformity is also studied as a function of the position of the incident particle inside the sensor pad.
△ Less
Submitted 17 March, 2023; v1 submitted 14 March, 2023;
originally announced March 2023.
-
Run 2 Upgrades to the CMS Level-1 Calorimeter Trigger
Authors:
B. Kreis,
J. Berryhill,
R. Cavanaugh,
K. Mishra,
R. Rivera,
L. Uplegger,
L. Apanasevich,
J. Zhang,
J. Marrouche,
N. Wardle,
R. Aggleton,
F. Ball,
J. Brooke,
D. Newbold,
S. Paramesvaran,
D. Smith,
M. Baber,
A. Bundock,
M. Citron,
A. Elwood,
G. Hall,
G. Iles,
C. Laner,
B. Penning,
A. Rose
, et al. (39 additional authors not shown)
Abstract:
The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed app…
▽ More
The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed approach allow for improved position and energy resolution. Data processing in both stages of the upgrade is performed with new, Xilinx Virtex-7 based AMC cards.
△ Less
Submitted 18 November, 2015;
originally announced November 2015.
-
Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube
Authors:
L. Cadamuro,
M. Calvi,
L. Cassina,
A. Giachero,
C. Gotti,
B. Khanji,
M. Maino,
C. Matteuzzi,
G. Pessina
Abstract:
The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect single photon signals make this tube suitable for an application in high energy physics, such as for RICH detectors. Four tubes and two different bias voltage divide…
▽ More
The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect single photon signals make this tube suitable for an application in high energy physics, such as for RICH detectors. Four tubes and two different bias voltage dividers have been tested. The results of a standard characterization of the gain and the anode uniformity, the dark signal rate, the cross-talk and the device behaviour as a function of temperature have been studied. The behaviour of the tube is studied in a longitudinal magnetic field up to 100 Gauss. Shields made of a high permeability material are also investigated. The deterioration of the device performance due to long time operation at intense light exposure is studied. A quantitative analysis of the variation of the gain and the dark signals rate due to the aging is described.
△ Less
Submitted 13 March, 2014;
originally announced March 2014.