Integrable Magnetic Fluid Hyperthermia Systems for 3D Magnetic Particle Imaging
Authors:
André Behrends,
Huimin Wei,
Alexander Neumann,
Thomas Friedrich,
Anna C. Bakenecker,
Matthias Graeser,
Thorsten M. Buzug
Abstract:
Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object tra…
▽ More
Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic par-ticle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
Moving Table Magnetic Particle Imaging: A stepwise approach preserving high spatio-temporal resolution
Authors:
Patryk Szwargulski,
Nadine Gdaniec,
Matthias Graeser,
Martin Möddel,
Florian Griese,
Kannan M. Krishnan,
Thorsten M. Buzug,
Tobias Knopp
Abstract:
Magnetic Particle Imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI the size of the field of view scales with the strengths of the applied magnetic fields. In clinical applications those strengths are limited by peripheral nerve stimulation, specific absorption rates,…
▽ More
Magnetic Particle Imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI the size of the field of view scales with the strengths of the applied magnetic fields. In clinical applications those strengths are limited by peripheral nerve stimulation, specific absorption rates, and the requirement to acquire images of high spatial resolution. Therefore, the size of the field of view is usually a few cubic centimeters. To bypass this limitation, additional focus fields and/or external object movements can be applied. In this work, the latter approach is investigated. An object is moved through the scanner bore one step at a time, while the MPI scanner continuously acquires data from its static field of view. Using a 3D phantom and dynamic 3D in vivo data it is shown that the data from such a moving table experiment can be jointly reconstructed after reordering the data with respect to the stepwise object shifts and heart beat phases.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
Authors:
Matthias Gräser,
Tobias Knopp,
Patryk Szwargulski,
Thomas Friedrich,
Anselm von Gladiss,
Michael Kaul,
Kannan M Krishnan,
Harald Ittrich,
Gerhard Adam,
Thorsten M. Buzug
Abstract:
Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first ha…
▽ More
Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the measurement of mice. The setup is capable of detecting 5 ng of iron in vitro at 2.14 sec acquisition time. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In vivo MPI mouse images of a 512 ng bolus at 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines improving the comparability of future MPI studies.
△ Less
Submitted 5 May, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.