-
Deep Few-view High-resolution Photon-counting Extremity CT at Halved Dose for a Clinical Trial
Authors:
Mengzhou Li,
Chuang Niu,
Ge Wang,
Maya R Amma,
Krishna M Chapagain,
Stefan Gabrielson,
Andrew Li,
Kevin Jonker,
Niels de Ruiter,
Jennifer A Clark,
Phil Butler,
Anthony Butler,
Hengyong Yu
Abstract:
The latest X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging for tissue characterization and material decomposition. However, both radiation dose and imaging speed need improvement for contrast-enhanced and other studies. Despite the success of deep learning methods for 2D few-view reconstruction, applying them to HR volumetric reconstr…
▽ More
The latest X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging for tissue characterization and material decomposition. However, both radiation dose and imaging speed need improvement for contrast-enhanced and other studies. Despite the success of deep learning methods for 2D few-view reconstruction, applying them to HR volumetric reconstruction of extremity scans for clinical diagnosis has been limited due to GPU memory constraints, training data scarcity, and domain gap issues. In this paper, we propose a deep learning-based approach for PCCT image reconstruction at halved dose and doubled speed in a New Zealand clinical trial. Particularly, we present a patch-based volumetric refinement network to alleviate the GPU memory limitation, train network with synthetic data, and use model-based iterative refinement to bridge the gap between synthetic and real-world data. The simulation and phantom experiments demonstrate consistently improved results under different acquisition conditions on both in- and off-domain structures using a fixed network. The image quality of 8 patients from the clinical trial are evaluated by three radiologists in comparison with the standard image reconstruction with a full-view dataset. It is shown that our proposed approach is essentially identical to or better than the clinical benchmark in terms of diagnostic image quality scores. Our approach has a great potential to improve the safety and efficiency of PCCT without compromising image quality.
△ Less
Submitted 18 March, 2024;
originally announced March 2024.
-
Broadband and Wide Angle Nonreciprocal Thermal Emission from Weyl Semimetal Structures
Authors:
A. Butler,
C. Argyropoulos
Abstract:
Nonreciprocal thermal emission is a cutting-edge technology that enables fundamental control over thermal radiation and has exciting applications in thermal energy harvesting. However, so far one of the foremost challenges is making nonreciprocal emission to operate over a broad wavelength range and for multiple angles. In this work, we solve this outstanding problem by proposing three different t…
▽ More
Nonreciprocal thermal emission is a cutting-edge technology that enables fundamental control over thermal radiation and has exciting applications in thermal energy harvesting. However, so far one of the foremost challenges is making nonreciprocal emission to operate over a broad wavelength range and for multiple angles. In this work, we solve this outstanding problem by proposing three different types of structures always utilizing only one Weyl semimetal (WSM) thin film combined with one or two additional dielectric or metallic layers and terminated by a metallic substrate. First a tradeoff relationship between the magnitude and bandwidth of the thermal nonreciprocity contrast is established based on the thickness of the WSM film. Then, the bandwidth broadening effect is demonstrated via the insertion of a dielectric spacer layer that can also be fine-tuned by varying its thickness. Finally, further control on the resulting strong nonreciprocal thermal radiation is demonstrated by the addition of a thin metallic layer in the proposed few layer designs. The presented composite structures work for a broad frequency range and multiple emission angles, consisting highly advantageous properties to various nonreciprocal thermal radiation applications. Moreover, the proposed designs do not require any patterning and can be experimentally realized by simple deposition fabrication methods. They are expected to aid in the creation of broadband nonreciprocal thermal emitters that can find applications in new energy harvesting devices.
△ Less
Submitted 27 June, 2023;
originally announced June 2023.
-
Plasmon Enhanced Quantum Properties of Single Photon Emitters with Hybrid Hexagonal Boron Nitride Silver Nanocube Systems
Authors:
Mohammadjavad Dowran,
Andrew Butler,
Suvechhya Lamichhane,
Adam Erickson,
Ufuk Kilic,
Sy-Hwang Liou,
Christos Argyropoulos,
Abdelghani Laraoui
Abstract:
Hexagonal boron nitride (hBN) has emerged as a promising ultrathin host of single photon emitters (SPEs) with favorable quantum properties at room temperature, making it a highly desirable element for integrated quantum photonic networks. One major challenge of using these SPEs in such applications is their low quantum efficiency. Recent studies have reported an improvement in quantum efficiency b…
▽ More
Hexagonal boron nitride (hBN) has emerged as a promising ultrathin host of single photon emitters (SPEs) with favorable quantum properties at room temperature, making it a highly desirable element for integrated quantum photonic networks. One major challenge of using these SPEs in such applications is their low quantum efficiency. Recent studies have reported an improvement in quantum efficiency by up to two orders of magnitude when integrating an ensemble of emitters such as boron vacancy defects in multilayered hBN flakes embedded within metallic nanocavities. However, these experiments have not been extended to SPEs and are mainly focused on multiphoton effects. Here, we study the quantum single photon properties of hybrid nanophotonic structures composed of SPEs created in ultrathin hBN flakes coupled with plasmonic silver nanocubes. We demonstrate > 200% plasmonic enhancement of the SPE properties, manifested by a strong increase in the SPE fluorescence. Such enhancement is explained by rigorous numerical simulations where the hBN flake is in direct contact with the Ag nanocubes that cause the plasmonic effects. The presented strong and fast single photon emission obtained at room-temperature with a compact hybrid nanophotonic platform can be very useful to various emerging applications in quantum optical communications and computing.
△ Less
Submitted 20 April, 2023; v1 submitted 1 April, 2023;
originally announced April 2023.
-
Exceptional points in parity-time symmetric plasmonic Huygens metasurfaces
Authors:
Andrew Butler,
Christos Argyropoulos
Abstract:
Parity-Time (PT) symmetric optical structures exhibit several unique and interesting characteristics with the most popular being exceptional points. While the emerging concept of PT-symmetry has been extensively investigated in bulky photonic designs, its exotic functionalities in nanophotonic non-Hermitian plasmonic systems still remain relatively unexplored. Towards this goal, in this work we an…
▽ More
Parity-Time (PT) symmetric optical structures exhibit several unique and interesting characteristics with the most popular being exceptional points. While the emerging concept of PT-symmetry has been extensively investigated in bulky photonic designs, its exotic functionalities in nanophotonic non-Hermitian plasmonic systems still remain relatively unexplored. Towards this goal, in this work we analyze the unusual properties of a plasmonic Huygens metasurface composed of an array of active metal-dielectric core-shell nanoparticles. By calculating the reflection and transmission coefficients of the metasurface under various levels of gain, we demonstrate the existence of reflectionless transmission when an exceptional point is formed. The proposed new active metasurface design has subwavelength thickness and can be used to realize ultracompact perfect transmission optical filters.
△ Less
Submitted 17 January, 2023;
originally announced January 2023.
-
Tunable Directional Filter for Mid-Infrared Optical Transmission Switching
Authors:
Andrew Butler,
Jack Schulz,
Christos Argyropoulos
Abstract:
Controlling the spectral and angular response of infrared (IR) radiation is a challenging task of paramount importance to various emerging photonic applications. Here, we overcome these problems by proposing and analyzing a new design of a tunable narrowband directional optical transmission filter. The presented thermally controlled multilayer filter leverages the temperature dependent phase chang…
▽ More
Controlling the spectral and angular response of infrared (IR) radiation is a challenging task of paramount importance to various emerging photonic applications. Here, we overcome these problems by proposing and analyzing a new design of a tunable narrowband directional optical transmission filter. The presented thermally controlled multilayer filter leverages the temperature dependent phase change properties of vanadium dioxide (VO2) to enable efficient and reversible fast optical switching by using a pump-probe laser excitation setup. More specifically, transmission is blocked for high intensity probe lasers due to the VO2 metallic properties induced at elevated temperatures while at low probe laser intensities high transmission through the filter occurs only for a narrowband IR range confined to near normal incident angles. The proposed multilayer composite dielectric filter is expected to have applications in optical communications, where it can act as dual functional infrared filter and optical switch.
△ Less
Submitted 26 September, 2022;
originally announced September 2022.
-
Motion Correction via Locally Linear Embedding for Helical Photon-counting CT
Authors:
Mengzhou Li,
Chiara Lowe,
Anthony Butler,
Phil Butler,
Ge Wang
Abstract:
X-ray photon-counting detector (PCD) offers low noise, high resolution, and spectral characterization, representing a next generation of CT and enabling new biomedical applications. It is well known that involuntary patient motion may induce image artifacts with conventional CT scanning, and this problem becomes more serious with PCD due to its high detector pitch and extended scan time. Furthermo…
▽ More
X-ray photon-counting detector (PCD) offers low noise, high resolution, and spectral characterization, representing a next generation of CT and enabling new biomedical applications. It is well known that involuntary patient motion may induce image artifacts with conventional CT scanning, and this problem becomes more serious with PCD due to its high detector pitch and extended scan time. Furthermore, PCD often comes with a substantial number of bad pixels, making analytic image reconstruction challenging and ruling out state-of-the-art motion correction methods that are based on analytical reconstruction. In this paper, we extend our previous locally linear embedding (LLE) cone-beam motion correction method to the helical scanning geometry, which is especially desirable given the high cost of large-area PCD. In addition to our adaption of LLE-based parametric searching to helical cone-beam photon-counting CT geometry, we introduce an unreliable-volume mask to improve the motion estimation accuracy and perform incremental updating on gradually refined sampling grids for optimization of both accuracy and efficiency. Our numerical results demonstrate that our method reduces the estimation errors near the two longitudinal ends of the reconstructed volume and overall image quality. The experimental results on clinical photon-counting scans of the patient extremities show significant resolution improvement after motion correction using our method, which reveals subtle fine structures previously hidden under motion blurring and artifacts.
△ Less
Submitted 5 April, 2022;
originally announced April 2022.
-
Mechanically Tunable Radiative Cooling for Adaptive Thermal Control
Authors:
Andrew Butler,
Christos Argyropoulos
Abstract:
Passive radiative cooling is currently the frontier technology in renewable-energy research. In terms of extraterrestrial applications, radiative cooling is a critical component to the thermal management system of a spacecraft, where the extreme environment of space can cause large temperature variations that can break and damage equipment. For terrestrial applications, nocturnal or daytime radiat…
▽ More
Passive radiative cooling is currently the frontier technology in renewable-energy research. In terms of extraterrestrial applications, radiative cooling is a critical component to the thermal management system of a spacecraft, where the extreme environment of space can cause large temperature variations that can break and damage equipment. For terrestrial applications, nocturnal or daytime radiative cooling is expected to lead to cost-effective passive heat management without the need of inefficient and costly artificial refrigeration technologies. However, most currently available radiative cooling systems cannot be changed dynamically and radiate a constant static amount of thermal power. Dynamically tunable adaptive radiative cooling systems will be a critical development to prolong the lifetime of spacecraft or improve the efficiency of terrestrial cooling systems. Here we propose stretchable radiative cooling designs that can be substantially tuned by using the simple physical mechanism of mechanical strain. When their structure is stretched, the radiated power is significantly reduced. We develop a modeling method that can simulate mechanical stretching combined with electromagnetic response to compute the tunable thermal emission of these new adaptive radiative cooling systems. The presented photonically engineered structures can be used as coatings to achieve efficient adaptive thermal control of various objects in a cost-effective and environmentally friendly way. The proposed designs are much simpler to be realized than others found in the literature and the best design achieves a high thermal emission power with a tunable range on the order of 132 W/m2.
△ Less
Submitted 24 March, 2022;
originally announced March 2022.
-
Near-field imaging of plasmonic nanopatch antennas with integrated semiconductor quantum dots
Authors:
Vasudevan Iyer,
Yoong Sheng Phang,
Andrew Butler,
Jiyang Chen,
Brian Lerner,
Christos Argyropoulos,
Thang Hoang,
Benjamin Lawrie
Abstract:
Plasmonic nanopatch antennas that incorporate dielectric gaps hundreds of picometers to several nanometers thick have drawn increasing attention over the past decade because they confine electromagnetic fields to grossly sub-diffraction limited volumes. Substantial control over the optical properties of excitons and color centers confined within these plasmonic cavities has already been demonstrat…
▽ More
Plasmonic nanopatch antennas that incorporate dielectric gaps hundreds of picometers to several nanometers thick have drawn increasing attention over the past decade because they confine electromagnetic fields to grossly sub-diffraction limited volumes. Substantial control over the optical properties of excitons and color centers confined within these plasmonic cavities has already been demonstrated with far-field optical spectroscopies, but near-field optical spectroscopies are essential to an improved understanding of the plasmon-emitter interaction at the nanoscale. Here, we characterize the intensity and phase-resolved plasmonic response of isolated nanopatch antennas with cathodoluminescence microscopy. Further, we explore the distinction between optical and electron-beam spectroscopies of coupled plasmon-exciton heterostructures to identify constraints and opportunities for future nanoscale characterization and control of hybrid nanophotonic structures. While we observe substantial Purcell enhancement in time-resolved photoluminescence spectroscopies, negligible Purcell enhancement is observed in cathodoluminescence spectroscopies of hybrid nanophotonic structures. The substantial differences in measured Purcell enhancement for electron-beam and laser excitation can be understood as a result of the different selection rules for these complementary experiments. These results provide a fundamentally new understanding of near-field plasmon-exciton interactions in nanopatch antennas that is essential to myriad emerging quantum photonic devices.
△ Less
Submitted 2 August, 2021;
originally announced August 2021.
-
The observation of vibrating pear shapes in radon nuclei: update
Authors:
P. A. Butler,
L. P. Gaffney,
P. Spagnoletti,
J. Konki,
M. Scheck,
J. F. Smith,
K. Abrahams,
M. Bowry,
J. Cederkäll,
T. Chupp,
G. De Angelis,
H. De Witte,
P. E. Garrett,
A. Goldkuhle,
C. Henrich,
A. Illana,
K. Johnston,
D. T. Joss,
J. M. Keatings,
N. A. Kelly,
M. Komorowska,
T. Kröll,
M. Lozano,
B. S. Nara Singh,
D. O'Donnell
, et al. (19 additional authors not shown)
Abstract:
There is a large body of evidence that atomic nuclei can undergo octupole distortion and assume the shape of a pear. This phenomenon is important for measurements of electric-dipole moments of atoms, which would indicate CP violation and hence probe physics beyond the standard model of particle physics. Isotopes of both radon and radium have been identified as candidates for such measurements. Her…
▽ More
There is a large body of evidence that atomic nuclei can undergo octupole distortion and assume the shape of a pear. This phenomenon is important for measurements of electric-dipole moments of atoms, which would indicate CP violation and hence probe physics beyond the standard model of particle physics. Isotopes of both radon and radium have been identified as candidates for such measurements. Here, we have observed the low-lying quantum states in $^{224}$Rn and $^{226}$Rn by accelerating beams of these radioactive nuclei. We report here additional states not assigned in our 2019 publication. We show that radon isotopes undergo octupole vibrations but do not possess static pear-shapes in their ground states. We conclude that radon atoms provide less favourable conditions for the enhancement of a measurable atomic electric-dipole moment.
△ Less
Submitted 10 June, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Evolution of Octupole Deformation in Radium Nuclei from Coulomb Excitation of Radioactive $^{222}$Ra and $^{228}$Ra Beams
Authors:
P. A. Butler,
L. P. Gaffney,
P. Spagnoletti,
K. Abrahams,
M. Bowry,
J. Cederkäll,
G. De Angelis,
H. De Witte,
P. E. Garrett,
A. Goldkuhle,
C. Henrich,
A. Illana,
K. Johnston,
D. T. Joss,
J. M. Keatings,
N. A. Kelly,
M. Komorowska,
J. Konki,
T. Kröll,
M. Lozano,
B. S. Nara Singh,
D. O'Donnell,
J. Ojala,
R. D. Page,
L. G. Pedersen
, et al. (18 additional authors not shown)
Abstract:
There is sparse direct experimental evidence that atomic nuclei can exhibit stable pear shapes arising from strong octupole correlations. In order to investigate the nature of octupole collectivity in radium isotopes, electric octupole ($E3$) matrix elements have been determined for transitions in $^{222,228}$Ra nuclei using the method of sub-barrier, multi-step Coulomb excitation. Beams of the ra…
▽ More
There is sparse direct experimental evidence that atomic nuclei can exhibit stable pear shapes arising from strong octupole correlations. In order to investigate the nature of octupole collectivity in radium isotopes, electric octupole ($E3$) matrix elements have been determined for transitions in $^{222,228}$Ra nuclei using the method of sub-barrier, multi-step Coulomb excitation. Beams of the radioactive radium isotopes were provided by the HIE-ISOLDE facility at CERN. The observed pattern of $E$3 matrix elements for different nuclear transitions is explained by describing $^{222}$Ra as pear-shaped with stable octupole deformation, while $^{228}$Ra behaves like an octupole vibrator.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Effects of Distributed Roughness on Crossflow Instability through Generalized Resonance Mechanisms
Authors:
Jiyang He,
Adam Butler,
Xuesong Wu
Abstract:
Experiments have shown that micron-sized distributed surface roughness can significantly promote transition in a three-dimensional boundary layer dominated by crossflow insta- bility. This sensitive effect has not yet been fully explained physically and mathematically. Unlike past researches focusing on the receptivity of the boundary layer to surface roughness, or on the local stability of the mo…
▽ More
Experiments have shown that micron-sized distributed surface roughness can significantly promote transition in a three-dimensional boundary layer dominated by crossflow insta- bility. This sensitive effect has not yet been fully explained physically and mathematically. Unlike past researches focusing on the receptivity of the boundary layer to surface roughness, or on the local stability of the modified mean flow, this paper seeks possible inherent mechanisms by investigating the effects of distributed surface roughness on crossflow instability through resonant interactions with eigenmodes. A key observation is that the perturbation induced by roughness with specific wavenumbers can interact with two eigenmodes (travelling and stationary vortices) through triadic resonance, or interact with one eigenmode (stationary vortices) through Bragg scattering. Unlike the usual triadic resonance of neutral, or nearly neutral, eigenmodes, the present triadic resonance can take place among modes with O(1) growth rates, provided that these are equal; unlike the usual Bragg scattering involving neutral waves, crossflow stationary vortices can also be unstable. For these amplifying waves, the generalized triadic resonance and Bragg scattering are put forward, and the resulting corrections to the growth rates are derived by a multiple-scale method. The analysis is extended to the case where up to four crossflow vortices interact with each other in the presence of suitable roughness components. The numerical results for Falkner-Skan-Cooke boundary layers show that roughness with a small height (a few percent of the local boundary-layer thickness) can change growth rates substantially (by a more-or-less O(1) amount)....
△ Less
Submitted 14 July, 2018;
originally announced July 2018.
-
MARS-MD: rejection based image domain material decomposition
Authors:
C. J. Bateman,
D. Knight,
B. Brandwacht,
J. Mc Mahon,
J. Healy,
R. Panta,
R. Aamir,
K. Rajendran,
M. Moghiseh,
M. Ramyar,
D. Rundle,
J. Bennett,
N. de Ruiter,
D. Smithies,
S. T. Bell,
R. Doesburg,
A. Chernoglazov,
V. B. H. Mandalika,
M. Walsh,
M. Shamshad,
M. Anjomrouz,
A. Atharifard,
L. Vanden Broeke,
S. Bheesette,
T. Kirkbride
, et al. (6 additional authors not shown)
Abstract:
This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problem…
▽ More
This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problems, each containing fewer materials; (2) solving each sub-problem; and (3) applying rejection criteria to eliminate all but one sub-problem's solution. An advantage of this process is that different constraints can be applied to each sub-problem if necessary. In addition, the result of this process is that solutions will be sparse in the material domain, which reduces crossover of signal between material images. Two algorithms based on this process are presented: the Segmentation variant, which uses segmented material classes to define each sub-problem; and the Angular Rejection variant, which defines the rejection criteria using the angle between reconstructed attenuation vectors.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
The SPEDE spectrometer
Authors:
P. Papadakis,
D. M. Cox,
G. G. O'Neill,
M. J. G. Borge,
P. A. Butler,
L. P. Gaffney,
P. T. Greenlees,
R. -D. Herzberg,
A. Illana,
D. T. Joss,
J. Konki,
T. Kröll,
J. Ojala,
R. D. Page,
P. Rahkila,
K. Ranttila,
J. Thornhill,
J. Tuunanen,
P. Van Duppen,
N. Warr,
J. Pakarinen
Abstract:
The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation…
▽ More
The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb-excitation experiments using radioactive ion beams.
△ Less
Submitted 21 September, 2017;
originally announced September 2017.
-
The Hidden K-edge Signal in K-edge Imaging
Authors:
Christopher J. Bateman,
Kishore Rajendran,
Niels J. A. de Ruiter,
Anthony P. Butler,
Philip H. Butler,
Peter F. Renaud
Abstract:
K-edge imaging is commonly used for viewing contrast pharmaceuticals in a variety of multi-energy x-ray imaging techniques, ranging from dual-energy and spectral computed tomography to fluoroscopy. When looking for the K-edge signal of a specific contrast, by taking measurements either side of the K-edge, it is found that the K-edge is not always observable for low concentrations. We have also obs…
▽ More
K-edge imaging is commonly used for viewing contrast pharmaceuticals in a variety of multi-energy x-ray imaging techniques, ranging from dual-energy and spectral computed tomography to fluoroscopy. When looking for the K-edge signal of a specific contrast, by taking measurements either side of the K-edge, it is found that the K-edge is not always observable for low concentrations. We have also observed that the ability to see the K-edge is unit dependent - a K-edge that is not observable in computed tomography (CT) reconstructed linear attenuation units can often be made visible by converting to Hounsfield units.
This paper presents an investigation of this K-edge hiding phenomenon. We conclude that if a multi-energy x-ray measurement of any K-edge material contains a signal of any other material, then there will be a positive concentration of that K-edge material below which its K-edge cannot be observed without extracting the K-edge signal through means of basis decomposition. Mathematical descriptions of this limiting minimum concentration is provided in three cases - multi-energy radiographic projection images; and reconstructed multi-energy CT images for both linear attenuation and Hounsfield units. Two important properties of this limiting concentration are provided: the minimum concentration for Hounsfield units is always strictly less than the minimum concentration for linear attenuation; and the minimum concentration for radiographic projections will typically be much larger than the minimum concentration for reconstructed linear attenuation. Finally experimental observation of this phenomenon is presented using data collected by the MARS spectral CT scanner equipped with a CdTe Medipix-3RX camera operating in charge-summing mode, where it is also shown that the K-edge can be recovered through basis decomposition.
△ Less
Submitted 13 June, 2015;
originally announced June 2015.
-
Design of a Marx-Topology Modulator for FNAL Linac
Authors:
T. A. Butler,
F. G. Garcia,
M. R. Kufer,
H. Pfeffer,
D. Wolff
Abstract:
The Fermilab Proton Improvement Plan (PIP) was formed in late 2011 to address important and necessary upgrades to the Proton Source machines (Injector line, Linac and Booster). The goal is to increase the proton flux by doubling the Booster beam cycle rate while maintaining the same intensity per cycle, the same uptime, and the same residual activation in the enclosure. For the Linac, the main foc…
▽ More
The Fermilab Proton Improvement Plan (PIP) was formed in late 2011 to address important and necessary upgrades to the Proton Source machines (Injector line, Linac and Booster). The goal is to increase the proton flux by doubling the Booster beam cycle rate while maintaining the same intensity per cycle, the same uptime, and the same residual activation in the enclosure. For the Linac, the main focus within PIP is to address reliability. One of the main tasks is to replace the present hard-tube modulator used on the 200 MHz RF system. Plans to replace this high power system with a Marx-topology modulator, capable of providing the required waveform sha** to stabilize the accelerating gradient and compensate for beam loading, will be presented, along with development data from the prototype unit.
△ Less
Submitted 28 April, 2015;
originally announced April 2015.
-
Alignment and resolution studies of a MARS scanner
Authors:
A. P. Butler,
P. H. Butler,
S. T. Bell,
G. Chelkov,
M. Demichev,
A. Gongadze,
S. Kotov,
D. Kozhevnikov,
U. Kruchonak,
I. Potrap,
P. Smolyanskiy,
A. Zhemchugov
Abstract:
The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise…
▽ More
The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise knowledge of several geometrical parameters of a tomograph, such as displacement of a rotation axis, x-ray source position with respect to a camera, and camera inclinations. Use of inaccurate parameters leads to a poor sample reconstruction. Non-ideal positioning of camera, x-ray source and cylindrical rotating frame (gantry) itself on which these parts are located, leads to the need for tomograph alignment. In this note we describe the alignment procedure that was used to get different geometrical corrections for the reconstruction. Also, several different estimations of the final spatial resolution for reconstructed images are presented.
△ Less
Submitted 23 March, 2015; v1 submitted 29 January, 2015;
originally announced January 2015.
-
Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip
Authors:
A. P. Butler,
P. H. Butler,
S. T. Bell,
G. A. Chelkov,
D. V. Dedovich,
M. A. Demichev,
V. G. Elkin,
M. I. Gostkin,
S. A. Kotov,
D. A. Kozhevnikov,
U. G. Kruchonak,
A. A. Nozdrin,
S. Yu. Porokhovoy,
I. N. Potrap,
P. I. Smolyanskiy,
M. M. Zakhvatkin,
A. S. Zhemchugov
Abstract:
This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with the resolution and the efficiency of the pixel detector is used for the calibration. The energy resolution of the detector is also measured during the calibratio…
▽ More
This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with the resolution and the efficiency of the pixel detector is used for the calibration. The energy resolution of the detector is also measured during the calibration. The use of per-pixel calibration allows to achieve a good energy resolution of the Timepix detector with GaAs:Cr sensor: 8% and 13% at 60 keV and 20 keV, respectively.
△ Less
Submitted 14 January, 2015;
originally announced January 2015.
-
Reducing beam hardening effects and metal artefacts using Medipix3RX: With applications from biomaterial science
Authors:
K. Rajendran,
M. F. Walsh,
N. J. A. de Ruiter,
A. I. Chernoglazov,
R. K. Panta,
A. P. H. Butler,
P. H. Butler,
S. T. Bell,
N. G. Anderson,
T. B. F. Woodfield,
S. J. Tredinnick,
J. L. Healy,
C. J. Bateman,
R. Aamir,
R. M. N. Doesburg,
P. F. Renaud,
S. P. Gieseg,
D. J. Smithies,
J. L. Mohr,
V. B. H. Mandalika,
A. M. T. Opie,
N. J. Cook,
J. P. Ronaldson,
S. J. Nik,
A. Atharifard
, et al. (6 additional authors not shown)
Abstract:
This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routi…
▽ More
This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routine. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. Narrow high energy acquisition using the photon-processing detector revealed substantial reduction in beam hardening effects and metal artefacts.
△ Less
Submitted 20 November, 2013;
originally announced November 2013.
-
MARS spectral molecular imaging of lamb tissue: data collection and image analysis
Authors:
R Aamir,
A Chernoglazov,
C J Bateman,
A P H Butler,
P H Butler,
N G Anderson,
S T Bell,
R K Panta,
J L Healy,
J L Mohr,
K Rajendran,
M F Walsh,
N de Ruiter,
S P Gieseg,
T Woodfield,
P F Renaud,
L Brooke,
S Abdul-Majid,
M Clyne,
R Glendenning,
P J Bones,
M Billinghurst,
C Bartneck,
H Mandalika,
R Grasset
, et al. (13 additional authors not shown)
Abstract:
Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectros…
▽ More
Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectroscopic photon-processing detector, to discriminate fat, calcium, and water in tissue. We present data collected from a sample of lamb meat including bone as an illustrative example of human tissue imaging. The data is analyzed using our 3D Algebraic Reconstruction Algorithm (MARS-ART) and by material decomposition based on a constrained linear least squares algorithm. The results presented here clearly show the quantification of lipid-like, water-like and bone-like components of tissue. However, it is also clear to us that better algorithms could extract more information of clinical interest from our data. Because we are one of the first to present data from multi-energy photon-processing small animal CT systems, we make the raw, partial and fully processed data available with the intention that others can analyze it using their familiar routines. The raw, partially processed and fully processed data of lamb tissue along with the phantom calibration data can be found at [http://hdl.handle.net/10092/8531].
△ Less
Submitted 23 January, 2014; v1 submitted 18 November, 2013;
originally announced November 2013.
-
Design, Implementation and First Measurements with the Medipix Neutron Camera in CMS
Authors:
Dorothea Pfeiffer,
Austin Ball,
Alan Bell,
Anthony Butler,
Philip Butler,
Richard Hall-Wilton,
Jeroen Hegeman,
Stuart Lansley,
Gary Keen,
David Krofcheck,
Steffen Mueller,
Alick Macpherson,
Stanislav Pospisil,
Hamish Silverwood,
Emmanuel Tsesmelis,
Zdenek Vykydal
Abstract:
The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the…
▽ More
The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux rate is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.
△ Less
Submitted 6 May, 2011;
originally announced May 2011.