-
Longitudinal spin-relaxation optimization for miniaturized optically pumped magnetometers
Authors:
A. P. McWilliam,
S. Dyer,
D. Hunter,
M. Mrozowski,
S. J. Ingleby,
O. Sharp,
D. P. Burt,
P. F. Griffin,
J. P. McGilligan,
E. Riis
Abstract:
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal re…
▽ More
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, $γ_{10}$, and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted through employing an optically pumped magnetometer operating in a free-induction-decay configuration. $γ_{10}$ is extracted across a range of nitrogen pressures between $\sim$~60~-~700~Torr, measuring a minimum of 140~Hz at 115~Torr. Additionally, we achieve sensitivities as low as 130 ~fT/$\sqrt{\text{Hz}}$ at a bias field amplitude of $\sim 50~μ$T. With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance.
△ Less
Submitted 3 July, 2024; v1 submitted 27 June, 2024;
originally announced June 2024.
-
Real-time buffer gas pressure tuning in a micro-machined vapor cell
Authors:
S. Dyer,
A. McWilliam,
D. Hunter,
S. Ingleby,
D. P. Burt,
O. Sharp,
F. Mirando,
P. F. Griffin,
E. Riis,
J. P. McGilligan
Abstract:
We demonstrate a controllable depletion of the nitrogen buffer gas pressure in a micro-machined cesium (Cs) vapor cell from the dynamic heating of an alkali dispenser pill. When the alkali source is laser activated, the gettering compounds within the alkali pill dispenser reduce the nitrogen (N$_2$) content from the vapor for fine-tuning of the alkali to buffer gas pressure ratio. Additionally, we…
▽ More
We demonstrate a controllable depletion of the nitrogen buffer gas pressure in a micro-machined cesium (Cs) vapor cell from the dynamic heating of an alkali dispenser pill. When the alkali source is laser activated, the gettering compounds within the alkali pill dispenser reduce the nitrogen (N$_2$) content from the vapor for fine-tuning of the alkali to buffer gas pressure ratio. Additionally, we decrease the buffer gas pressure below 100$\,$mTorr to evaluate the presence of other potential broadening mechanisms. Real-time control of the gas pressure ratio in the vapor cell will have notable benefits for refining atomic sensor performance and provide a routine to achieve various target pressures across a wafer bonded with a uniform back-filled buffer gas pressure.
△ Less
Submitted 12 April, 2023;
originally announced April 2023.
-
Micro-machined deep silicon atomic vapor cells
Authors:
S. Dyer,
P. F. Griffin,
A. S. Arnold,
F. Mirando,
D. P. Burt,
E. Riis,
J. P. McGilligan
Abstract:
Using a simple and cost-effective water jet process, silicon etch depth limitations are overcome to realize a $6\,$mm deep atomic vapor cell. While the minimum silicon feature size was limited to a $1.5\,$mm width in these first generation vapor cells, we successfully demonstrate a two-chamber geometry by including a $\sim$25~mm meandering channel between the alkali pill chamber and main interroga…
▽ More
Using a simple and cost-effective water jet process, silicon etch depth limitations are overcome to realize a $6\,$mm deep atomic vapor cell. While the minimum silicon feature size was limited to a $1.5\,$mm width in these first generation vapor cells, we successfully demonstrate a two-chamber geometry by including a $\sim$25~mm meandering channel between the alkali pill chamber and main interrogation chamber. We evaluate the impact of the channel conductance on the introduction of alkali vapor density during the pill activation process, and mitigate glass damage and pill contamination near the main chamber. Finally, we highlight the improved signal achievable in the $6\,$mm silicon cell compared to standard $2\,$mm path length silicon vapor cells.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
A simple imaging solution for chip-scale laser cooling
Authors:
A. Bregazzi,
P. F. Griffin,
A. S. Arnold,
D. P. Burt,
G. Martinez,
R. Boudot,
J. Kitching,
E. Riis,
J. P. McGilligan
Abstract:
We demonstrate a simple stacked scheme that enables absorption imaging through a hole in the surface of a grating magneto-optical trap (GMOT) chip, placed immediately below a micro-fabricated vacuum cell. The imaging scheme is capable of overcoming the reduced optical access and surface scatter that is associated with this chip-scale platform, while further permitting both trap** and imaging of…
▽ More
We demonstrate a simple stacked scheme that enables absorption imaging through a hole in the surface of a grating magneto-optical trap (GMOT) chip, placed immediately below a micro-fabricated vacuum cell. The imaging scheme is capable of overcoming the reduced optical access and surface scatter that is associated with this chip-scale platform, while further permitting both trap** and imaging of the atoms from a single incident laser beam. The through-hole imaging is used to characterise the impact of the reduced optical overlap volume of the GMOT in the chip-scale cell, with an outlook to an optimised atom number in low volume systems.
△ Less
Submitted 26 August, 2021;
originally announced August 2021.
-
Stand-alone vacuum cell for compact ultracold quantum technologies
Authors:
Oliver S. Burrow,
Paul F. Osborn,
Edward Boughton,
Francesco Mirando,
David P. Burt,
Paul F. Griffin,
Aidan S. Arnold,
Erling Riis
Abstract:
Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pum** is often required. Here, we present a centilitre-scale ceramic v…
▽ More
Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pum** is often required. Here, we present a centilitre-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fibre. A cold atom demonstrator based on the vacuum cell delivers $10^7$ laser-cooled $^{87}$Rb atoms per second, using minimal electrical power. With continuous Rb gas emission active pum** yields a $10^{-7}\,$mbar equilibrium pressure, and passive pum** stabilises to $3\times 10^{-6}\,$mbar, with a $17\,$day time constant. A vacuum cell, with no Rb dispensing and only passive pum**, has currently kept a similar pressure for more than \ch{500 days}. The passive-pum** vacuum lifetime is several years, estimated from short-term He throughput, with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.
△ Less
Submitted 2 September, 2021; v1 submitted 19 January, 2021;
originally announced January 2021.