-
Measurement of the permanent electric dipole moment of the neutron
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Burghoff,
E. Chanel,
Z. Chowdhuri,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
B. Franke,
A. Fratangelo,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten
, et al. (59 additional authors not shown)
Abstract:
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19…
▽ More
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection
Authors:
N. Sachdeva,
I. Fan,
E. Babcock,
M. Burghoff,
T. E. Chupp,
S. Degenkolb,
P. Fierlinger,
S. Haude,
E. Kraegeloh,
W. Kilian,
S. Knappe-Grüneberg,
F. Kuchler,
T. Liu,
M. Marino,
J. Meinel,
K. Rolfs,
Z. Salhi,
A. Schnabel,
J. T. Singh,
S. Stuiber,
W. A. Terrano,
L. Trahms,
J. Voigt
Abstract:
We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement camp…
▽ More
We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst})\times10^{-28}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 1.4 \times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of five more sensitive than the limit set in 2001.
△ Less
Submitted 26 September, 2019;
originally announced September 2019.
-
Towards direct neuronal current imaging via ultra-low-field MR
Authors:
Nora Höfner,
Rainer Körber,
Martin Burghoff
Abstract:
The feasibility of using ultra-low-field magnetic resonance (ULF MR) for direct neuronal current imaging (NCI) is investigated by phantom measurements. The aim of NCI is to improve the current localization accuracy for neuronal activity of established methods like electroencephalography (EEG) or magnetoencephalography (MEG) (~1 cm). A measurement setup was developed addressing the main challenge o…
▽ More
The feasibility of using ultra-low-field magnetic resonance (ULF MR) for direct neuronal current imaging (NCI) is investigated by phantom measurements. The aim of NCI is to improve the current localization accuracy for neuronal activity of established methods like electroencephalography (EEG) or magnetoencephalography (MEG) (~1 cm). A measurement setup was developed addressing the main challenge of reaching the necessary sensitivity in order to possibly resolve the faint influence of neuronal magnetic fields on 1H nuclear spin precession. Phantom measurements close to physiology conditions are performed simulating a specific long-lasting neuronal activity evoked in the secondary somatosensory cortex showing that the signal-to-noise ratio (SNR) of the setup needs to be further increased by at least a factor of 2.
△ Less
Submitted 26 June, 2019;
originally announced June 2019.
-
A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection
Authors:
N. Sachdeva,
I. Fan,
E. Babcock,
M. Burghoff,
T. E. Chupp,
S. Degenkolb,
P. Fierlinger,
E. Kraegeloh,
W. Kilian,
S. Knappe-Grüneberg,
F. Kuchler,
T. Liu,
M. Marino,
J. Meinel,
Z. Salhi,
A. Schnabel,
J. T. Singh,
S. Stuiber,
W. A. Terrano,
L. Trahms,
J. Voigt
Abstract:
We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systemat…
▽ More
We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systematic effects is $d_A(^{129}\mathrm{Xe}) = (0.26 \pm 2.33_\mathrm{stat} \pm 0.72_\mathrm{syst})\times10^{-27}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 4.81\times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of 1.4 more sensitive than the previous limit.
△ Less
Submitted 7 February, 2019;
originally announced February 2019.
-
A modular, extendible and field-tolerant multichannel vector magnetometer based on current sensor SQUIDs
Authors:
Jan-Hendrik Storm,
Dietmar Drung,
Martin Burghoff,
Rainer Körber
Abstract:
We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and spin precession. Further demanding applications are magnetorelaxometry and ultra-low-field nuclear magnetic resonance (ULF NMR), where pulsed fields of up to 10…
▽ More
We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and spin precession. Further demanding applications are magnetorelaxometry and ultra-low-field nuclear magnetic resonance (ULF NMR), where pulsed fields of up to 100 mT are typically applied. The system is operated inside the Berlin Magnetically Shielded Room and equipped with 18 magnetometers consisting of niobium (Nb) wire-wound pick-up coils. A total of 16 small pick-up coils with 17.1 mm diameter form a regular grid with individual channels arranged to ensure system sensitivity covers all three orthogonal spatial directions. Two large hexagonal pick-up coils with an equivalent diameter of 74.5 mm sensitive in z-direction surround the grid at two different heights and are suitable for the detection of deep sources. Each coil is connected to the input of a thin-film Nb SQUID current sensor via a detachable superconducting contact. The SQUIDs are equipped with integrated input current limiters. Feedback into the pick-up coils minimizes crosstalk between channels. The current sensor chip package includes a superconducting shield of Nb. The field distortion of the prototype and a multi-module arrangement was analysed by numerical simulation. The measured noise of the small magnetometers was between 0.6 and 1.5 fT/Hz$^{1/2}$, and well below 1 fT/Hz$^{1/2}$ for the large ones. Using a software gradiometer, we achieved a minimum noise level of 0.54 fT/Hz$^{1/2}$. We performed ULF NMR experiments, verifying the system's robustness against pulsed fields, and magnetoencephalographgy (MEG) on somatosensory evoked neuronal activity. The low noise performance of our 18-channel prototype enabled the detection of high-frequency components at around 1 kHz by MEG.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
Authors:
J. M. Pendlebury,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss
, et al. (25 additional authors not shown)
Abstract:
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calcula…
▽ More
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL).
This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.
△ Less
Submitted 13 October, 2015; v1 submitted 15 September, 2015;
originally announced September 2015.
-
A measurement of the neutron to 199Hg magnetic moment ratio
Authors:
S. Afach,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
Z. Grujic,
P. G. Harris,
W. Heil,
V. Hélaine,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
A. Knecht
, et al. (29 additional authors not shown)
Abstract:
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.
△ Less
Submitted 31 October, 2014; v1 submitted 30 October, 2014;
originally announced October 2014.
-
A magnetically shielded room with ultra low residual field and gradient
Authors:
I. Altarev,
E. Babcock,
D. Beck,
M. Burghoff,
S. Chesnevskaya,
T. Chupp,
S. Degenkolb,
I. Fan,
P. Fierlinger,
A. Frei,
E. Gutsmiedl,
S. Knappe-Grüneberg,
F. Kuchler,
T. Lauer,
P. Link,
T. Lins,
M. Marino,
J. McAndrew,
B. Niessen,
S. Paul,
G. Petzoldt,
U. Schläpfer,
A. Schnabel,
S. Sharma,
J. Singh
, et al. (7 additional authors not shown)
Abstract:
A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental p…
▽ More
A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus.
△ Less
Submitted 24 March, 2014;
originally announced March 2014.
-
An Improved Search for the Neutron Electric Dipole Moment
Authors:
M. Burghoff,
A. Schnabel,
G. Ban,
T. Lefort,
Y. Lemiere,
O. Naviliat-Cuncic,
E. Pierre,
G. Quemener,
J. Zejma,
M. Kasprzak,
P. Knowles,
A. Weis,
G. Pignol,
D. Rebreyend,
S. Afach,
G. Bison,
J. Becker,
N. Severijns,
S. Roccia,
C. Plonka-Spehr,
J. Zennerz,
W. Heil,
H. C. Koch,
A. Kraft,
T. Lauer
, et al. (12 additional authors not shown)
Abstract:
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved…
▽ More
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
Ultra-sensitive magnetometry based on free precession of nuclear spins
Authors:
C. Gemmel,
W. Heil,
K. Lenz,
Ch. Ludwig,
K. Thulley,
Yu. Sobolev,
M. Burghoff,
S. Knappe-Grueneberg,
W. Kilian,
W. Mueller,
A. Schnabel,
F. Seifert,
L. Trahms,
St. Baessler
Abstract:
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be employed to control fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron as well as in…
▽ More
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be employed to control fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron as well as in a new type of 3He/129Xe clock comparison experiment which should be sensitive to a sidereal variation of the relative spin precession frequency. Characteristic spin precession times T_2 of up to 60h could be measured. In combination with a signal-to-noise ratio of > 5000:1, this leads to a sensitivity level of deltaB= 1fT after an integration time of 220s and to deltaB= 10^(-4)fT after one day. Even in that sensitivity range, the magnetometer performance is statistically limited, and noise sources inherent to the magnetometer are not limiting. The reason is that free precessing 3He (129Xe) nuclear spins are almost completely decoupled from the environment. That makes this type of magnetometer in particular attractive for precision field measurements where a long-term stability is required.
△ Less
Submitted 22 May, 2009;
originally announced May 2009.