Injection and capture of antiprotons in a Penning-Malmberg trap using a drift tube accelerator and degrader foil
Authors:
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
M. Hori,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Maeckel,
S. Migliorati,
D. J. Murtagh,
Y. Nagata
, et al. (11 additional authors not shown)
Abstract:
The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate…
▽ More
The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate antiprotons and optimize the injection energy into the degrader foils. By increasing the beam energy to 119 keV, a cooled antiproton accumulation efficiency of (26 +- 6)% was achieved.
△ Less
Submitted 11 June, 2024; v1 submitted 14 March, 2024;
originally announced March 2024.
-
Upgrade of the positron system of the ASACUSA-Cusp experiment
Authors:
A. Lanz,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
D. J. Murtagh,
A. Nanda,
L. Nowak
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator a…
▽ More
The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator and therefore decreasing the number of transfer cycles, the contamination of the vacuum has been reduced. Further to this, a new rare gas moderator and buffer gas trap, previously used at the Aarhus University, were installed. Measurements from Aarhus suggested that the number of positrons could be increased by a factor of four in comparison to the old system used at CERN. This would mean a reduction of the time needed for accumulating a sufficient number of positrons (of the order of a few million) for an antihydrogen production cycle. Initial tests have shown that the new system yields a comparable number of positrons to the old system.
△ Less
Submitted 14 July, 2023; v1 submitted 12 July, 2023;
originally announced July 2023.
-
Slow positron production and storage for the ASACUSA-Cusp experiment
Authors:
D. J. Murtagh,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Mal\-bru\-not,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
A. Nanda,
L. Nowak
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in po…
▽ More
The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in positron accumulation by a factor of ($52\pm3)$
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
SDR, EVC, and SDREVC: Limitations and Extensions
Authors:
E. D. Hunter,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
D. J. Murtagh,
A. Nanda,
L. Nowak
, et al. (12 additional authors not shown)
Abstract:
Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrat…
▽ More
Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrate (2) an alternative to SDREVC, using e-kick instead of EVC and (3) an upper limit for how much plasma can be cooled to T < 20 K using EVC. This limit depends on the space charge, not on the number of particles or the plasma density.
△ Less
Submitted 3 June, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.