-
TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector
Authors:
E. Albuquerque,
M. Araújo,
A. Benaglia,
A. Boletti,
R. Bugalho,
T. Coutinho,
F. De Guio,
P. Faccioli,
L. Ferramacho,
M. Firlej,
T. Fiutowski,
R. Francisco,
M. Gallinaro,
A. Ghezzi,
J. Hollar,
M. Idzik,
H. Legoinha,
N. Leonardo,
C. Leong,
M. T. Lucchini,
M. Malberti,
G. Marozzo,
G. Da Molin,
J. Moron,
T. Niknejad
, et al. (16 additional authors not shown)
Abstract:
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.…
▽ More
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.
△ Less
Submitted 1 April, 2024;
originally announced April 2024.
-
The CGEM-IT readout chain
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
R. Bugalho,
A. Calcaterra,
S. Cerioni,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
A. Di Francesco,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
S. Garbolino,
I. Garzia,
M. Gatta
, et al. (22 additional authors not shown)
Abstract:
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output b…
▽ More
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.
△ Less
Submitted 17 August, 2021; v1 submitted 19 May, 2021;
originally announced May 2021.
-
Design and performance of the TIGER front-end ASIC for the BESIII Cylindrical Gas Electron Multiplier detector
Authors:
Fabio Cossio,
Maxim Alexeev,
Ricardo Bugalho,
Junying Chai,
Weishuai Cheng,
Manuel D. Da Rocha Rolo,
Agostino Di Francesco,
Michela Greco,
Chongyang Leng,
Huaishen Li,
Marco Maggiora,
Simonetta Marcello,
Marco Mignone,
Angelo Rivetti,
Joao Varela,
Richard Wheadon
Abstract:
We present the design and characterization of TIGER (Turin Integrated Gem Electronics for Readout), a 64-channel ASIC developed for the readout of the CGEM (Cylindrical Gas Electron Multiplier) detector, the proposed inner tracker for the 2018 upgrade of the BESIII experiment, carried out at BEPCII in Bei**g. Each ASIC channel features a charge sensitive amplifier coupled to a dual-branch shaper…
▽ More
We present the design and characterization of TIGER (Turin Integrated Gem Electronics for Readout), a 64-channel ASIC developed for the readout of the CGEM (Cylindrical Gas Electron Multiplier) detector, the proposed inner tracker for the 2018 upgrade of the BESIII experiment, carried out at BEPCII in Bei**g. Each ASIC channel features a charge sensitive amplifier coupled to a dual-branch shaper stage, optimized for timing and charge measurement, followed by a mixed-mode back-end that extracts and digitizes the timestamp and charge of the input signals. The time-of-arrival is provided by a set of low-power TDCs, based on analogue interpolation techniques, while the charge measurement is obtained either from the Time-over-Threshold information or with a sample-and-hold circuit. The ASIC has been fabricated in a 110 nm CMOS technology and designed to operate with a 1.2 V power supply, an input capacitance of about 100 pF, an input dynamic range between 3 and 50 fC, a power consumption of about 12 mW/channel and a sustained event rate of 60 kHz/channel. The design and test results of TIGER first prototype are presented showing its full functionality.
△ Less
Submitted 13 March, 2019;
originally announced March 2019.
-
Online energy discrimination at DAQ front-end level on pixelated TOF-PET systems
Authors:
C. Zorraquino,
L. Ferramacho,
R. Bugalho,
M. Zvolsky,
T. Niknejad,
J. C. Silva,
S. Tavernier,
P. Guerra,
J. Varela,
A. Santos
Abstract:
Pixelated PET systems produce higher count rates as they integrate several detecting channels per detector module. An increased data flow from the detectors posses higher needs on the bandwidth requirements. We aim to optimize the bandwidth usage efficiency by filtering on the fly the detected events with non valid energies. PET systems with a SiPM-ASIC readout scheme are being extensively used to…
▽ More
Pixelated PET systems produce higher count rates as they integrate several detecting channels per detector module. An increased data flow from the detectors posses higher needs on the bandwidth requirements. We aim to optimize the bandwidth usage efficiency by filtering on the fly the detected events with non valid energies. PET systems with a SiPM-ASIC readout scheme are being extensively used to get enhanced images on Time-Of-Flight PET scanners. These kind of digital readout systems are specially interesting for the application of on-line processing techniques given the ease of access to each detected event digital information. This study purses the analysis of on-line processing techniques on the DAQ front-end level (on-detector electronics) for pixelated PET systems with SiPM-ASIC readout. In particular, we worked with a tunable on-line energy discriminating stage. For the optimization of its hardwired internal limits we analyzed the system energy space. We explored different solutions dependent or not on the system's energy calibration. Results obtained through the different filter versions confirm the minimal resources consumption of such processing techniques implemented at DAQ front-end level. Our experiences showed how the filtering process reduces the bandwidth needs excluding from the data stream all non valid energy events and thus improving the system sensitivity under saturation conditions. Additionally, these experiments highlight how setting proper energy limits we ensure the preservation of the system performance, which maintains its original energy and time resolution. Under the light of these findings, we see a great potential on the application of on-line processing techniques for Time-Of-Flight PET at the DAQ font-end level (on-detector electronics) and so we envisaged more complex processing methods.
△ Less
Submitted 4 April, 2018; v1 submitted 6 February, 2018;
originally announced February 2018.
-
A custom readout electronics for the BESIII CGEM detector
Authors:
M. Da Rocha Rolo,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
R. Bugalho,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
A. Di Francesco,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava
, et al. (31 additional authors not shown)
Abstract:
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to…
▽ More
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to reduce the total number of channels to about 10 000. The channels are readout by 160 dedicated integrated 64-channel front-end ASICs, providing a time and charge measurement and featuring a fully-digital output. The energy measurement is extracted either from the time-over-threshold (ToT) or the 10-bit digitisation of the peak amplitude of the signal. The time of the event is generated by quad-buffered low-power TDCs, allowing for rates in excess of 60 kHz per channel. The TDCs are based on analogue interpolation techniques and produce a time stamp (or two, if working in ToT mode) of the event with a time resolution better than 50 ps. The front-end noise, based on a CSA and CR-RC2 shapers, dominate the channel intrinsic time jitter, which is less than 5 ns r.m.s.. The time information of the hit can be used to reconstruct the track path, operating the detector as a small TPC and hence improving the position resolution when the distribution of the cloud, due to large incident angle or magnetic field, is very broad. Event data is collected by an off-detector motherboard, where each GEM-ROC readout card handles 4 ASIC carrier PCBs (512 channels). Configuration upload and data readout between the off-detector electronics and the VME-based data collector cards are managed by bi-directional fibre optical links.
△ Less
Submitted 28 June, 2017; v1 submitted 7 June, 2017;
originally announced June 2017.
-
Asymmetric Data Acquisition System for an Endoscopic PET-US Detector
Authors:
Carlos Zorraquino,
Ricardo Bugalho,
Manuel Rolo,
Jose C. Silva,
Viesturs Vecklans,
Rui Silva,
Catarina Ortigao,
Jorge A. Neves,
Stefaan Tavernier,
Pedro Guerra,
Joao Varela
Abstract:
According to current prognosis studies of pancreatic cancer, survival rate nowadays is still as low as 6% mainly due to late detections. Taking into account the location of the disease within the body and making use of the level of miniaturization in radiation detectors that can be achieved at the present time, EndoTOFPET-US collaboration aims at the development of a multimodal imaging technique f…
▽ More
According to current prognosis studies of pancreatic cancer, survival rate nowadays is still as low as 6% mainly due to late detections. Taking into account the location of the disease within the body and making use of the level of miniaturization in radiation detectors that can be achieved at the present time, EndoTOFPET-US collaboration aims at the development of a multimodal imaging technique for endoscopic pancreas exams that combines the benefits of high resolution metabolic information from Time-Of- Flight (TOF) Positron Emission Tomography (PET) and anatomical information from ultrasound (US). A system with such capabilities calls for an application-specific high-performance Data Acquisition System (DAQ) able to control and readout data from two different detectors.
△ Less
Submitted 3 November, 2015; v1 submitted 16 June, 2014;
originally announced June 2014.