A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 25 June, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
Single channel PICOSEC Micromegas detector with improved time resolution
Authors:
A. Utrobicic,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (25 additional authors not shown)
Abstract:
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo…
▽ More
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.