-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Challenges for the interaction region design of the Future Circular Collider FCC-ee
Authors:
Manuela Boscolo,
Nicola Bacchetta,
Michael Benedikt,
Laurent Brunetti,
Helmut Burkhardt,
Andrea Ciarma,
Mogens Dam,
Francesco Fransesini,
Mark Jones,
Roberto Kersevan,
Mike Koratzinos,
Marian Lueckhof,
Mauro Migliorati,
Eva Montbarbon,
Alexander Novokhatski,
Katsunobu Oide,
Luigi Pellegrino,
Freddy Poirier,
Maurizio Serluca,
Michael K. Sullivan,
Leonard Watrelot,
Frank Zimmermann
Abstract:
The FCC-ee is a proposed future high-energy, high-intensity and high-precision lepton collider. Here, we present the latest development for the FCC-ee interaction regions, which shall ensure optimum conditions for the particle physics experiments. We discuss measures of background reduction and a revised interaction region layout including a low impedance compact beam chamber design. We also discu…
▽ More
The FCC-ee is a proposed future high-energy, high-intensity and high-precision lepton collider. Here, we present the latest development for the FCC-ee interaction regions, which shall ensure optimum conditions for the particle physics experiments. We discuss measures of background reduction and a revised interaction region layout including a low impedance compact beam chamber design. We also discuss the possible impact of the radiation generated in the interaction region including beamstrahlung.
△ Less
Submitted 20 May, 2021;
originally announced May 2021.
-
Thermoelectric Sensors as Microcalorimeter Load
Authors:
L. Brunetti,
L. Oberto,
E. Vremera
Abstract:
Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward frequency limited. At INRiM the high frequency power standards are now based on coaxial thermocouples from dc to 34 GHz. Modified commercial thermocouple mounts in 7…
▽ More
Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward frequency limited. At INRiM the high frequency power standards are now based on coaxial thermocouples from dc to 34 GHz. Modified commercial thermocouple mounts in 7 mm and 3.5 mm coaxial line are used to realize the national power standard with an accuracy ranging from 0.03 % to 1 % in the mentioned frequency range.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
On Coaxial Microcalorimeter Calibration
Authors:
L. Brunetti,
L. Oberto
Abstract:
Primary power standards in the microwave domain are realized using a calorimetric technique, usually identified with the used measurement system, i.e., the microcalorimeter. It is adjusted for measurement of power ratios with a relative accuracy that, after an appropriate system calibration, is of order of 10^-3, at least in the microwave domain (1 GHz-18 GHz). Hereby we describe the calibration p…
▽ More
Primary power standards in the microwave domain are realized using a calorimetric technique, usually identified with the used measurement system, i.e., the microcalorimeter. It is adjusted for measurement of power ratios with a relative accuracy that, after an appropriate system calibration, is of order of 10^-3, at least in the microwave domain (1 GHz-18 GHz). Hereby we describe the calibration process implemented at the Istituto Nazionale di Ricerca Metrologica (Italy) for realizing a coaxial power standard based on indirect heating thermocouples. Particular regard is devoted to describe the nearly ideal thermal load used for determining the microcalorimeter losses and their influence on the measurand accuracy.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
Improvement of primary power standard through international comparison feedback
Authors:
Luciano Brunetti,
Luca Oberto,
Marco Sellone
Abstract:
The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of power sensors both of bolometric and thermoelectric type. The critical point in the power standard realization is in the determination of the calibration const…
▽ More
The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of power sensors both of bolometric and thermoelectric type. The critical point in the power standard realization is in the determination of the calibration constant g of the microcalorimeter, a frequency dependent parameter that has huge impact on the accuracy as-sessment of the standard. The paper proposes a simple but powerful way for improving this accuracy by using the reference values provided by in-ternational key-comparisons which the microcalorimeter was involved in.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
Alternative Procedures in Realizing of the High Frequency Power Standards with Microcalorimeter and Thermoelectric Power Sensors
Authors:
Emil Vremera,
Luciano Brunetti,
Luca Oberto,
Marco Sellone
Abstract:
The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The presented procedures involve microcalorimeter measurement and calibration steps, parameters computation and systematic errors correction for both long-term and acce…
▽ More
The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The presented procedures involve microcalorimeter measurement and calibration steps, parameters computation and systematic errors correction for both long-term and accelerated algorithms. Also, a new method for determining the key parameters of high frequency power standards is proposed.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
Comparison Among Coaxial Microcalorimeter Models
Authors:
L. Brunetti,
L. Oberto,
M. Sellone,
E. Vremera
Abstract:
Thermoelectric power sensors used as power transfer standards are promising devices for further enhancements of the microcalorimetric technique in the high frequency field. A coaxial microcalorimeter has been studied, based on thermoelectric power sensors, at Istituto Nazionale di Ricerca Metrologica (INRIM). In the literature, several models have been proposed, considering different calibration p…
▽ More
Thermoelectric power sensors used as power transfer standards are promising devices for further enhancements of the microcalorimetric technique in the high frequency field. A coaxial microcalorimeter has been studied, based on thermoelectric power sensors, at Istituto Nazionale di Ricerca Metrologica (INRIM). In the literature, several models have been proposed, considering different calibration processes and error sources. Hereby we analyze these models in terms of total uncertainty for the 3.5 mm coaxial line case between 10 MHz and 26.5 GHz. Merits and limits of the models are highlighted.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
Comparison between Thermoelectric and Bolometric Microwave Power Standards
Authors:
Luciano Brunetti,
Luca Oberto,
Marco Sellone,
Emil Vremera
Abstract:
In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have been carried out with the classical twin-type microcalorimeter, fitted with N-connector test ports suitable for the frequency band 0.05 - 18 GHz. An appropriate measurand definition is given for being suitable to both s…
▽ More
In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have been carried out with the classical twin-type microcalorimeter, fitted with N-connector test ports suitable for the frequency band 0.05 - 18 GHz. An appropriate measurand definition is given for being suitable to both standard types. A system accuracy assessment is performed applying the Gaussian error propagation through the mathematical models that interpret the microcalorimeter response in each case. The results highlight advantages and weaknesses of each power standard type.
△ Less
Submitted 23 February, 2021;
originally announced February 2021.
-
Improvements on INRIM Coaxial Microcalorimeter and Outcome of a Model Comparison
Authors:
Luciano Brunetti,
Luca Oberto,
Marco Sellone,
Nosherwan Shoaib,
Emil Vremera
Abstract:
This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency band 0.05 - 40 GHz. A better temperature and power stabilization turned out to provide an improved signal/noise ratio and a drift reduction in every working condition of the microcalorimeter. The INRIM correction model…
▽ More
This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency band 0.05 - 40 GHz. A better temperature and power stabilization turned out to provide an improved signal/noise ratio and a drift reduction in every working condition of the microcalorimeter. The INRIM correction model is also compared to a traditional, but faster, one in terms of measurement uncertainty. Outcomes are presented in form of a 2.92 mm thermoelectric power sensor calibration together with results that show the improved stability and repeatability of the measurement system.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Uncertainty Analysis for Material Measurements Using the Vector Network Analyzer
Authors:
Nosherwan Shoaib,
Marco Sellone,
Luciano Brunetti,
Luca Oberto
Abstract:
This paper presents the characterization measurements and related uncertainty evaluation of a nonmagnetic material using the Vector Network Analyzer (VNA) at microwave frequencies. The permittivity of the material under test is computed from the scattering parameters (S-parameters). The aim of the work is to highlight the different uncertainty contributions affecting the permittivity.
This paper presents the characterization measurements and related uncertainty evaluation of a nonmagnetic material using the Vector Network Analyzer (VNA) at microwave frequencies. The permittivity of the material under test is computed from the scattering parameters (S-parameters). The aim of the work is to highlight the different uncertainty contributions affecting the permittivity.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
RF/MW power standard realization without unitary efficiency assumption at dc/LF
Authors:
Luca Oberto,
Luciano Brunetti
Abstract:
Thermoelectric power sensors are widely used in commercial power meters at RF and microwaves, due to their superior robustness, stability, and accuracy if compared with other types of power sensors. Furthermore, their electrical architecture and related performance turned out to be very useful in the realization of the broadband primary power standards as alternative to resistive power sensors, i.…
▽ More
Thermoelectric power sensors are widely used in commercial power meters at RF and microwaves, due to their superior robustness, stability, and accuracy if compared with other types of power sensors. Furthermore, their electrical architecture and related performance turned out to be very useful in the realization of the broadband primary power standards as alternative to resistive power sensors, i.e. bolometers. Hereby we present a comparison in term of effective efficiency of a thermoelectric sensor calibrated by applying two different methods of power substitution when used as thermal load in a coaxial microcalorimeter at RF and microwaves. The aim is to test a technology that could enable the realization of a primary RF/MW power standard independently of the assumption of unitary efficiency at the dc (or LF) reference power.
△ Less
Submitted 10 February, 2021;
originally announced February 2021.
-
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
Authors:
B. Aimard,
L. Aizawa,
C. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (138 additional authors not shown)
Abstract:
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passi…
▽ More
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.
△ Less
Submitted 20 December, 2020; v1 submitted 16 October, 2020;
originally announced October 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
Authors:
B. Aimard,
Ch. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
M. M. Badoi,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (147 additional authors not shown)
Abstract:
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kin…
▽ More
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of 3x1x1 $m^3$ has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.
△ Less
Submitted 19 October, 2018; v1 submitted 8 June, 2018;
originally announced June 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
The camera of the fifth H.E.S.S. telescope. Part I: System description
Authors:
J. Bolmont,
P. Corona,
P. Gauron,
P. Ghislain,
C. Goffin,
L. Guevara Riveros,
J. -F. Huppert,
O. Martineau-Huynh,
P. Nayman,
J. -M. Parraud,
J. -P. Tavernet,
F. Toussenel,
D. Vincent,
P. Vincent,
W. Bertoli,
P. Espigat,
M. Punch,
D. Besin,
E. Delagnes,
J. -F. Glicenstein,
Y. Moudden,
P. Venault,
H. Zaghia,
L. Brunetti,
P. -Y. David
, et al. (32 additional authors not shown)
Abstract:
In July 2012, as the four ground-based gamma-ray telescopes of the H.E.S.S. (High Energy Stereoscopic System) array reached their tenth year of operation in Khomas Highlands, Namibia, a fifth telescope took its first data as part of the system. This new Cherenkov detector, comprising a 614.5 m^2 reflector with a highly pixelized camera in its focal plane, improves the sensitivity of the current ar…
▽ More
In July 2012, as the four ground-based gamma-ray telescopes of the H.E.S.S. (High Energy Stereoscopic System) array reached their tenth year of operation in Khomas Highlands, Namibia, a fifth telescope took its first data as part of the system. This new Cherenkov detector, comprising a 614.5 m^2 reflector with a highly pixelized camera in its focal plane, improves the sensitivity of the current array by a factor two and extends its energy domain down to a few tens of GeV.
The present part I of the paper gives a detailed description of the fifth H.E.S.S. telescope's camera, presenting the details of both the hardware and the software, emphasizing the main improvements as compared to previous H.E.S.S. camera technology.
△ Less
Submitted 26 May, 2014; v1 submitted 22 October, 2013;
originally announced October 2013.
-
Status of the Super-B factory Design
Authors:
W. Wittmer,
K. Bertsche,
A. Chao,
A. Novokhatski,
Y. Nosochkov,
J. Seeman,
M. K. Sullivan,
U. Wienands,
S. Weathersby,
A. V. Bogomyagkov,
E. Levichev,
S. Nikitin,
P. Piminov,
D. Shatilov,
S. Sinyatkin,
P. Vobly,
I. N. Okunev,
B. Bolzon,
L. Brunetti,
A. Jeremie,
M. E. Biagini,
R. Boni,
M. Boscolo,
T. Demma,
A. Drago
, et al. (20 additional authors not shown)
Abstract:
The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 10…
▽ More
The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 10$^{36}$ cm$^{-2}$ sec$^{-1}$. This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the $Υ$(4S) resonance. The present design is based on extremely low emittance beams colliding at a large Piwinski angle to allow very low $β_y^\star$ without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and allowing for a higher beam-beam parameter. The project has flexible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal polarization of the electron beam at the Interaction Point. Optimized for best colliding-beam performance, the facility may also provide high-brightness photon beams for synchrotron radiation applications.
△ Less
Submitted 9 October, 2011;
originally announced October 2011.
-
The True-Twin microcalorimeter: a proof-of-concept experiment
Authors:
Luca Oberto,
Luciano Brunetti,
Marco Sellone
Abstract:
We present a proof-of-concept experiment to realize microwave primary power standard with a true-twin microcalorimeter. Double feeding line microcalorimeters are widely used by National Metrology Institutes. A drawback concerns the system calibration: traditional processes changes measurement conditions between system characterization and the measurement stage. Nevertheless, if the feeding lines a…
▽ More
We present a proof-of-concept experiment to realize microwave primary power standard with a true-twin microcalorimeter. Double feeding line microcalorimeters are widely used by National Metrology Institutes. A drawback concerns the system calibration: traditional processes changes measurement conditions between system characterization and the measurement stage. Nevertheless, if the feeding lines are made twin, a measurement scheme that avoids separate characterization can be applied, equations simplify and time consumption is halved. Here we demonstrates the feasibility of the idea. The result of an effective efficiency spectroscopy of a thermoelectric power sensor is compared with figures obtained with well established methods.
△ Less
Submitted 2 May, 2011;
originally announced May 2011.
-
Realization and preliminary measurements on a 94 GHz SIS mixer
Authors:
L. Oberto,
N. De Leo,
M. Fretto,
A. Tartari,
L. Brunetti,
V. Lacquaniti
Abstract:
In this paper we present the realization and a preliminary characterization of a SIS based receiver. It has been developed for the MASTER experiment that consists in a three-band SIS receiver (94, 225 and 345 GHz) for astrophysical observations through the atmospheric windows available at high altitude dry sites. The measurements performed establish an upper limit to the overall receiver noise tem…
▽ More
In this paper we present the realization and a preliminary characterization of a SIS based receiver. It has been developed for the MASTER experiment that consists in a three-band SIS receiver (94, 225 and 345 GHz) for astrophysical observations through the atmospheric windows available at high altitude dry sites. The measurements performed establish an upper limit to the overall receiver noise temperature. A comparison has been tried with the MASTER requirements and with state of the art results. A noise figure of 110 K has been obtained at 94 GHz, about 22 times the quantum limit.
△ Less
Submitted 17 September, 2010; v1 submitted 11 May, 2010;
originally announced May 2010.