-
neuSIM4: A comprehensive GEANT4 based neutron simulation code
Authors:
J. Park,
F. C. E. Teh,
M. B. Tsang,
K. W. Brown,
Z. Chajecki,
B. Hong,
T. Lokotko,
W. G. Lynch,
J. Wieske,
K. Zhu
Abstract:
A new neutron SIMulation program based on the versatile GEANT4 toolkit, neuSIM4, has been developed to describe interactions of neutrons in the NE213 liquid scintillator from 0.1 to 3000 MeV. neuSIM4 is designed to accommodate complicated modern detector geometry setups with multiple scintillator detectors, each of which can be outfitted with more than one photo-multiplier. To address a broad spec…
▽ More
A new neutron SIMulation program based on the versatile GEANT4 toolkit, neuSIM4, has been developed to describe interactions of neutrons in the NE213 liquid scintillator from 0.1 to 3000 MeV. neuSIM4 is designed to accommodate complicated modern detector geometry setups with multiple scintillator detectors, each of which can be outfitted with more than one photo-multiplier. To address a broad spectrum of neutron energies, two new neutron interaction physics models, KSCIN and NxQMD, have been implemented in GEANT4. For neutrons with energy below 110 MeV, we incorporate a total of eleven neutron induced reaction channels on hydrogen and carbon nuclei, including nine carbon inelastic reaction channels, into KSCIN. Beyond 110 MeV, we implement a neutron induced reaction model, NxQMD, in GEANT4. We use its results as reference to evaluate other neutron-interaction physics models in GEANT4. We find that results from an existing cascade physics model (INCL) in GEANT4 agree very well with the results from NxQMD, and results from both codes agree with new and existing light response data. To connect KSCIN to NxQMD or INCL, we introduce a transition region where the contribution of neuSIM4 linearly decreases with corresponding increased contributions from NxQMD or INCL. To demonstrate the application of the new code, we simulate the light response and performance of a 2 x 2 m2 neutron detector wall array consisting of 25 2m-long scintillation bars. We are able to compare the predicted light response functions to the shape of the experimental response functions and calculate the efficiency of the neutron detector array for neutron energies up to 200 MeV. These simulation results will be pivotal for understanding the performance of modern neutron arrays with intricate geometries, especially in the measurements of neutron energy spectra in heavy-ion reactions.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Determination of energy-dependent neutron backgrounds using shadow bars
Authors:
S. N. Paneru,
K. W. Brown,
F. C. E Teh,
K. Zhu,
M. B. Tsang,
D. DellAquila,
Z. Chajecki,
W. G. Lynch,
S. Sweany,
C. Y. Tsang,
A. K. Anthony,
J. Barney,
J. Estee,
I. Gasparic,
G. Jhang,
O. B. Khanal,
J. Mandredi,
C. Y. Niu,
R. S. Wang,
J. C. Zamora
Abstract:
Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. In the analysis presented here, the shadow bars are placed in front of neutron detectors to determine the energy dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutr…
▽ More
Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. In the analysis presented here, the shadow bars are placed in front of neutron detectors to determine the energy dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
In-flight production of an isomeric beam of $^{16}$N
Authors:
C. R. Hoffman,
T. L. Tang,
M. Avila,
Y. Ayyad,
K. W. Brown,
J. Chen,
K. A. Chipps,
H. Jayatissa,
B. P. Kay,
C. Müller-Gatermann,
H. J. Ong,
J. Song,
G. L. Wilson
Abstract:
An in-flight beam of $^{16}$N was produced via the single-neutron adding ($d$,$p$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the $^{16}$N beam which resided in its excited 0.120-MeV $J^π=0^-$ isomeric state (T$_{1/2}\approx5$ $μ$s) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$u$, and 2…
▽ More
An in-flight beam of $^{16}$N was produced via the single-neutron adding ($d$,$p$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the $^{16}$N beam which resided in its excited 0.120-MeV $J^π=0^-$ isomeric state (T$_{1/2}\approx5$ $μ$s) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$u$, and 24(2)% at a reaction energy of 13.2(2) MeV/$u$. The isomer measurements took place at an experimental station $\approx30$ m downstream of the production target and utilized an Al beam-stop** foil and a HPGe Clover detector. Composite $^{16}$N beam rate determinations were made at the experimental station and the focal plane of the Argonne in-flight radioactive ion-beam separator (RAISOR) with Si $Δ$E-E telescopes. A Distorted Wave Born Approximation (DWBA) approach was coupled with the known spectroscopic information on $^{16}$N in order to estimate the relative $^{16}$N isomer yields and composite $^{16}$N beam rates. In addition to the observed reaction-energy dependence of the isomer fraction, a large sensitivity to angular acceptance of the recoils was also observed.
△ Less
Submitted 15 April, 2022; v1 submitted 27 January, 2022;
originally announced February 2022.
-
Beam Particle Identification and Tagging of Incompletely Stripped Heavy Beams with HEIST
Authors:
A. K. Anthony,
C. Y. Niu,
R. S. Wang,
J. Wieske,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
Y. Ayyad,
J. Barney,
T. Baumann,
D. Bazin,
S. Beceiro-Novo,
J. Boza,
J. Chen,
K. J. Cook,
M. Cortesi,
T. Ginter,
W. Mittig,
A. Pype,
M. K. Smith,
C. Soto,
C. Sumithrarachchi,
J. Swaim,
S. Sweany,
F. C. E. Teh
, et al. (4 additional authors not shown)
Abstract:
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure time of flight, a multi-sampling ion chamber to measure energy loss, and a high purity Ge detector to i…
▽ More
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure time of flight, a multi-sampling ion chamber to measure energy loss, and a high purity Ge detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified $^{198}$Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89\% of all $^{198}$Pb$^{+80}$ in the beam had a purity of 86\%. We examine the issues of charge state contamination. The observed charge state populations of these ions are presented and are moderately well described by the charge state model GLOBAL.
△ Less
Submitted 23 August, 2021; v1 submitted 28 July, 2021;
originally announced July 2021.
-
Value-assigned pulse shape discrimination for neutron detectors
Authors:
F. C. E. Teh,
J. -W. Lee,
K. Zhu,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
M. B. Tsang,
A. Anthony,
J. Barney,
D. Dell'Aquila,
J. Estee,
B. Hong,
G. Jhang,
O. B. Khanal,
Y. J. Kim,
H. S. Lee,
J. W. Lee,
J. Manfredi,
S. H. Nam,
C. Y. Niu,
J. H. Park,
S. Sweany,
C. Y. Tsang,
R. Wang,
H. Wu
Abstract:
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a photomultiplier tube (PMT) at each end. The new improved method, called the ``valued-assigned PSD'' (VPSD), assigns a normalized fitting residual to every waveform as…
▽ More
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a photomultiplier tube (PMT) at each end. The new improved method, called the ``valued-assigned PSD'' (VPSD), assigns a normalized fitting residual to every waveform as the PSD value. This procedure then facilitates the incorporation of longitudinal position dependence of the scintillator, which further enhances the PSD capability of the detector system. In this paper, we use radiation emitted from an AmBe neutron source to demonstrate that the resulting neutron-gamma identification has been much improved when compared to the traditional technique that uses the geometric mean of light outputs from both PMTs. The new method has also been modified and applied to a recent experiment at the National Superconducting Cyclotron Laboratory (NSCL) that uses an analog electronic system.
△ Less
Submitted 17 June, 2021; v1 submitted 15 January, 2020;
originally announced January 2020.
-
Non-linearity effects on the light-output calibration of light charged particles in CsI(Tl) scintillator crystals
Authors:
D. Dell'Aquila,
S. Sweany,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
F. C. E. Teh,
C. -Y. Tsang,
M. B. Tsang,
K. Zhu,
C. Anderson,
A. Anthony,
S. Barlini,
J. Barney,
A. Camaiani,
G. Jhang,
J. Crosby,
J. Estee,
M. Ghazali,
F. Guan,
O. Khanal,
S. Kodali,
I. Lombardo,
J. Manfredi,
L. Morelli,
P. Morfouace
, et al. (2 additional authors not shown)
Abstract:
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48Ca + CH2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with dir…
▽ More
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48Ca + CH2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with direct low-energy beams. We also use the punch through points of p, d, and t particles from 40,48Ca + 58,64Ni, 112,124Sn collisions reactions at 139.8 MeV/u. Non-linearities, arising in particular from Tl do** and light collection efficiency in the CsI crystals, are found to significantly affect the light output and therefore the calibration of the detector response for light charged particles, especially the hydrogen isotopes. A new empirical parametrization of the hydrogen light output, L(E,Z=1,A), is proposed to account for the observed effects. Results are found to be consistent for all 48 CsI(Tl) crystals in a cluster of 12 HiRA10 telescopes.
△ Less
Submitted 21 March, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
On Determining Dead Layer and Detector Thicknesses for a Position-Sensitive Silicon Detector
Authors:
J. Manfredi,
Jenny Lee,
W. G. Lynch,
C. Y. Niu,
M. B. Tsang,
C. Anderson,
J. Barney,
K. W. Brown,
Z. Chajecki,
K. P. Chan,
G. Chen,
J. Estee,
Z. Li,
C. Pruitt,
A. M. Rogers,
A. Sanetullaev,
H. Setiawan,
R. Showalter,
C. Y. Tsang,
J. R. Winkelbauer,
Z. Xiao,
Z. Xu
Abstract:
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and the overall thickness of the detector itself. The dead layer thickness for each E detector in HiRA is extracted using a measurement of alpha particles emitted f…
▽ More
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and the overall thickness of the detector itself. The dead layer thickness for each E detector in HiRA is extracted using a measurement of alpha particles emitted from a $^{212}$Pb pin source placed close to the detector surface. This procedure also allows for energy calibrations of the E detectors, which are otherwise inaccessible for alpha source calibration as each one is sandwiched between two other detectors. The E detector thickness is obtained from a combination of elastically scattered protons and an energy-loss calculation method. Results from these analyses agree with values provided by the manufacturer.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.