First results of spherical GEMs
Authors:
Serge Duarte Pinto,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis,
Hans Taureg,
Marco Villa
Abstract:
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at w…
▽ More
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles.
Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the limit of the angular acceptance of the detector. With these components first tests are done in a setup with a spherical entrance window but a planar readout structure; results will be presented and discussed.
A flat readout structure poses difficulties, however. Therefore we will show advanced plans to make a prototype of an entirely spherical double-GEM detector, including a spherical 2D readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability.
△ Less
Submitted 24 November, 2010;
originally announced November 2010.
-
Progress on large area GEMs (VCI 2010)
Authors:
Marco Villa,
Serge Duarte Pinto,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Hans Taureg,
Miranda van Stenis
Abstract:
The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in lar…
▽ More
The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in large area GEMs have also been addressed. Using the new improvements it was possible to build a prototype triple-GEM detector of ~ 2000 cm2 active area, aimed at an application for the TOTEM T1 upgrade. Further refinements of the single mask technique give great control over the shape of the GEM holes and the size of the rims, which can be tuned as needed. In this framework, simulation studies can help to understand the GEM behavior depending on the hole shape.
△ Less
Submitted 7 July, 2010;
originally announced July 2010.
-
Spherical GEMs for parallax-free detectors
Authors:
Serge Duarte Pinto,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis,
Hans Taureg,
Marco Villa
Abstract:
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial…
▽ More
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. The method is inexpensive and flexible towards possible changes in the design.
We show advanced plans to make a prototype of an entirely spherical triple-GEM detector, including a spherical readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability. A completely spherical gaseous detector has never been made before.
△ Less
Submitted 17 November, 2009;
originally announced November 2009.
-
Progress on large area GEMs
Authors:
Serge Duarte Pinto,
Marco Villa,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis
Abstract:
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development.
A single-mask technique overcomes the cumbersome p…
▽ More
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development.
A single-mask technique overcomes the cumbersome practice of alignment of two masks, which limits the achievable lateral size. The holes obtained with this technique are conical, and have a so-called rim, a small insulating clearance around the hole in the substrate. Further refinements of this technique allow greater control over the shape of holes and the size of rims. Also, an improvement in homogeneity over large areas is expected.
Simulation studies have been done to examine the effect of hole shape on the behavior of GEMs. Such studies can help understanding how to use new enhancements of the technique to optimize performance.
Many potential applications for large area GEMs foresee large production volumes. Production issues have been studied, and single-mask GEMs turn out to be much more suitable for large scale production than standard GEMs.
△ Less
Submitted 26 November, 2009; v1 submitted 28 September, 2009;
originally announced September 2009.
-
Making spherical GEMs
Authors:
Serge Duarte Pinto,
Marco Villa,
Matteo Alfonsi,
Ian Brock,
Gabriele Croci,
Eric David,
Rui de Oliveira,
Leszek Ropelewski,
Miranda van Stenis,
Hans Taureg
Abstract:
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap for x-rays can be formed. This would eliminate the parallax error in an x-ray diffraction setup, which limits the spatial resolution at wide diffraction angles. The method is inexpensi…
▽ More
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap for x-rays can be formed. This would eliminate the parallax error in an x-ray diffraction setup, which limits the spatial resolution at wide diffraction angles. The method is inexpensive and flexible towards possible changes in the design.
We show advanced plans to make a prototype of an entirely spherical triple-GEM detector, including a spherical readout structure. This detector will have a superior position resolution, also at wide diffraction angles, and a high rate capability. A completely spherical gaseous detector has never been made before.
△ Less
Submitted 6 November, 2009; v1 submitted 18 September, 2009;
originally announced September 2009.
-
The design and performance of the ZEUS Micro Vertex detector
Authors:
A. Polini,
I. Brock,
S. Goers,
A. Kappes,
U. F. Katz,
E. Hilger,
J. Rautenberg,
A. Weber,
A. Mastroberardino,
E. Tassi,
V. Adler,
L. A. T. Bauerdick,
I. Bloch,
T. Haas,
U. Klein,
U. Koetz,
G. Kramberger,
E. Lobodzinska,
R. Mankel,
J. Ng,
D. Notz,
M. C. Petrucci,
B. Surrow,
G. Watt,
C. Youngman
, et al. (57 additional authors not shown)
Abstract:
In order to extend the tracking acceptance, to improve the primary and secondary vertex reconstruction and thus enhancing the tagging capabilities for short lived particles, the ZEUS experiment at the HERA Collider at DESY installed a silicon strip vertex detector. The barrel part of the detector is a 63 cm long cylinder with silicon sensors arranged around an elliptical beampipe. The forward pa…
▽ More
In order to extend the tracking acceptance, to improve the primary and secondary vertex reconstruction and thus enhancing the tagging capabilities for short lived particles, the ZEUS experiment at the HERA Collider at DESY installed a silicon strip vertex detector. The barrel part of the detector is a 63 cm long cylinder with silicon sensors arranged around an elliptical beampipe. The forward part consists of four circular shaped disks. In total just over 200k channels are read out using $2.9 {\rm m^2}$ of silicon. In this report a detailed overview of the design and construction of the detector is given and the performance of the completed system is reviewed.
△ Less
Submitted 21 August, 2007;
originally announced August 2007.