Skip to main content

Showing 1–39 of 39 results for author: Breton, D

Searching in archive physics. Search in all archives.
.
  1. arXiv:2404.10565  [pdf

    cond-mat.mtrl-sci cond-mat.mes-hall physics.app-ph

    Electronic Properties of Electroactive Ferrocenyl-Functionalized MoS2

    Authors: Trung Nghia Nguyên Lê, Kirill Kondratenko, Imane Arbouch, Alain Moréac, d Jean-Christophe Le Breton, Colin van Dyck, Jérôme Cornil, Dominique Vuillaume, Bruno Fabre

    Abstract: The attachment of redox active molecules to transition metal dichalcogenides (TMDs), such as MoS2, constitutes a promising approach for designing electrochemically switchable devices through the control of the material charge/spin transport properties by the redox state of the grafted molecule and thus the applied electrical potential. In this work, defective plasma treated MoS2 is functionalized… ▽ More

    Submitted 16 April, 2024; originally announced April 2024.

    Comments: Full manuscript with figures and supporting information

    Journal ref: J. Phys. Chem. C, 128, 7706-7722 (2024)

  2. arXiv:2401.17003  [pdf, other

    physics.ins-det physics.med-ph

    Characterization of the BOLDPET optical prototype, an innovative Cherenkov detector for 511 keV $γ$ radiation

    Authors: Roman Chyzh, Gerard Tauzin, Dominique Yvon, Chi-Hsun Sung, Dominique Breton, Jihane Maalmi, Klaus Schäfers, Christian Weinheimer, Viatcheslav Sharyy

    Abstract: In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET technology uses an innovative detection liquid, trimethylbismuth, for detecting 511 keV $γ$-quanta resulting from positron annihilation. The optical signal is exclus… ▽ More

    Submitted 2 July, 2024; v1 submitted 30 January, 2024; originally announced January 2024.

    Comments: Accepted by JINST

  3. arXiv:2312.13169  [pdf, other

    physics.ins-det physics.med-ph

    First ClearMind gamma detector prototype for TOF-PET imaging

    Authors: A. Galindo-Tellez, V. Sharyy, C. -H. Sung, M. Follin, L. Cappellugola, S. Curtoni, M. Dupont, C. Morel, D. Breton, J. Maalmi, D. Yvon

    Abstract: The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crystal, which is encapsulated within a commercial Micro-Channel Plate Photomultiplier tube MAPMT253 with a bialkali photocathode directly deposited on the crystal. We… ▽ More

    Submitted 27 June, 2024; v1 submitted 20 December, 2023; originally announced December 2023.

    Comments: 23 pages, 24 figures

  4. arXiv:2312.07365  [pdf, other

    physics.ins-det hep-ex

    First characterization of a novel grain calorimeter: the GRAiNITA prototype

    Authors: Sergey Barsuk, Oleg Bezshyyko, Ianina Boyarintseva, Andrey Boyarintsev, Dominique Breton, Hervé Chanal, Alexander M. Dubovik, Andrii Kotenko, Giulia Hull, Jacques Lefrançois, Stéphane Monteil, Marie-Hélène Schune, Nazar Semkiv, Irina Tupitsyna, Mykhailo Yeresko

    Abstract: A novel type of calorimeter based on grains of inorganic scintillating crystal readout by wave length shifting fibers is proposed. The concept and main features as well as the prototype design are introduced and the first results obtained using cosmic rays are presented. The number of photo-electrons generated by cosmic rays muons in the prototype detector is estimated to be of the order of 10000… ▽ More

    Submitted 12 February, 2024; v1 submitted 12 December, 2023; originally announced December 2023.

    Comments: 11 pages, 7 figures

    Journal ref: Journal of Instrumentation, Volume 19, April 2024 2024

  5. arXiv:2308.04154  [pdf

    physics.geo-ph hep-ex physics.ins-det

    Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos

    Authors: LiquidO Consortium, :, A. Cabrera, M. Chen, F. Mantovani, A. Serafini, V. Strati, J. Apilluelo, L. Asquith, J. L. Beney, T. J. C. Bezerra, M. Bongrand, C. Bourgeois, D. Breton, M. Briere, J. Busto, A. Cadiou, E. Calvo, V. Chaumat, E. Chauveau, B. J. Cattermole, P. Chimenti, C. Delafosse, H. de Kerret, S. Dusini , et al. (55 additional authors not shown)

    Abstract: The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity… ▽ More

    Submitted 23 August, 2023; v1 submitted 8 August, 2023; originally announced August 2023.

  6. arXiv:2308.00515  [pdf, other

    hep-ex physics.ins-det

    Technical Design Report for the LUXE Experiment

    Authors: H. Abramowicz, M. Almanza Soto, M. Altarelli, R. Aßmann, A. Athanassiadis, G. Avoni, T. Behnke, M. Benettoni, Y. Benhammou, J. Bhatt, T. Blackburn, C. Blanch, S. Bonaldo, S. Boogert, O. Borysov, M. Borysova, V. Boudry, D. Breton, R. Brinkmann, M. Bruschi, F. Burkart, K. Büßer, N. Cavanagh, F. Dal Corso, W. Decking , et al. (109 additional authors not shown)

    Abstract: This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger fiel… ▽ More

    Submitted 2 August, 2023; v1 submitted 1 August, 2023; originally announced August 2023.

  7. arXiv:2303.05172  [pdf, other

    hep-ex physics.ins-det

    The JUNO experiment Top Tracker

    Authors: JUNO Collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Abid Aleem, Tsagkarakis Alexandros, Fengpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Weidong Bai, Nikita Balashov, Wander Baldini, Andrea Barresi, Davide Basilico, Eric Baussan, Marco Bellato , et al. (592 additional authors not shown)

    Abstract: The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector… ▽ More

    Submitted 9 March, 2023; originally announced March 2023.

    Comments: 20 pages

    Journal ref: Nucl.Instrum.Meth.A 1057 (2023) 168680

  8. arXiv:2303.03910  [pdf, other

    hep-ex physics.ins-det

    JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos

    Authors: Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Abid Aleem, Tsagkarakis Alexandros, Fengpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Weidong Bai, Nikita Balashov, Wander Baldini, Andrea Barresi, Davide Basilico, Eric Baussan, Marco Bellato, Marco Beretta , et al. (592 additional authors not shown)

    Abstract: The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented… ▽ More

    Submitted 7 March, 2023; originally announced March 2023.

  9. Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence

    Authors: Chi-Hsun Sung, Laurie Cappellugola, Megane Follin, Sébastien Curtoni, Mathieu Dupont, Christian Morel, Aline Galindo-Tellez, Roman Chyzh, Dominique Breton, Jihane Maalmi, Dominique Yvon, Viatcheslav Sharyy

    Abstract: The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result t… ▽ More

    Submitted 26 January, 2023; v1 submitted 23 September, 2022; originally announced September 2022.

  10. arXiv:2205.08830  [pdf, other

    hep-ex astro-ph.HE hep-ph physics.ins-det

    Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO

    Authors: JUNO Collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Fengpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Nikita Balashov, Wander Baldini, Andrea Barresi, Davide Basilico, Eric Baussan, Marco Bellato, Antonio Bergnoli, Thilo Birkenfeld, Sylvie Blin , et al. (577 additional authors not shown)

    Abstract: We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n… ▽ More

    Submitted 13 October, 2022; v1 submitted 18 May, 2022; originally announced May 2022.

    Comments: 29 pages, 11 figures, final published version in JCAP

    Journal ref: JCAP 10 (2022) 033

  11. arXiv:2205.08629  [pdf, other

    physics.ins-det hep-ex

    Mass Testing and Characterization of 20-inch PMTs for JUNO

    Authors: Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Abid Aleem, Tsagkarakis Alexandros, Fengpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, Joao Pedro Athayde Marcondes de Andre, Didier Auguste, Weidong Bai, Nikita Balashov, Wander Baldini, Andrea Barresi, Davide Basilico, Eric Baussan, Marco Bellato, Antonio Bergnoli , et al. (541 additional authors not shown)

    Abstract: Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic… ▽ More

    Submitted 17 September, 2022; v1 submitted 17 May, 2022; originally announced May 2022.

  12. arXiv:2203.17053  [pdf, other

    physics.ins-det hep-ex

    Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network

    Authors: DUNE Collaboration, A. Abed Abud, B. Abi, R. Acciarri, M. A. Acero, M. R. Adames, G. Adamov, M. Adamowski, D. Adams, M. Adinolfi, A. Aduszkiewicz, J. Aguilar, Z. Ahmad, J. Ahmed, B. Aimard, B. Ali-Mohammadzadeh, T. Alion, K. Allison, S. Alonso Monsalve, M. AlRashed, C. Alt, A. Alton, R. Alvarez, P. Amedo, J. Anderson , et al. (1204 additional authors not shown)

    Abstract: Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det… ▽ More

    Submitted 30 June, 2022; v1 submitted 31 March, 2022; originally announced March 2022.

    Comments: 31 pages, 15 figures

    Report number: FERMILAB-PUB-22-240-AD-ESH-LBNF-ND-SCD, CERN-EP-2022-077

    Journal ref: Eur.Phys.J.C 82 (2022) 10, 903

  13. arXiv:2203.16134  [pdf, other

    physics.ins-det

    Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC

    Authors: DUNE Collaboration, A. Abed Abud, B. Abi, R. Acciarri, M. A. Acero, M. R. Adames, G. Adamov, M. Adamowski, D. Adams, M. Adinolfi, A. Aduszkiewicz, J. Aguilar, Z. Ahmad, J. Ahmed, B. Aimard, B. Ali-Mohammadzadeh, T. Alion, K. Allison, S. Alonso Monsalve, M. AlRashed, C. Alt, A. Alton, R. Alvarez, P. Amedo, J. Anderson , et al. (1202 additional authors not shown)

    Abstract: DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and… ▽ More

    Submitted 3 June, 2022; v1 submitted 30 March, 2022; originally announced March 2022.

    Comments: 31 pages, 29 figures

    Report number: CERN-EP-DRAFT-MISC-2022-003; FERMILAB-PUB-22-242-LBNF

  14. arXiv:2202.09684  [pdf, other

    hep-ex physics.ins-det

    Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter

    Authors: I. Laktineh, B. Liu, D. Boumediene, Y. W. Baek, D-W. Kim, S. C. Lee, B. G. Min, S. W. Park, Y. Deguchi, K. Kawagoe, Y. Miura, R. Mori, I. Sekiya, T. Suehara, T. Yoshioka, L. Caponetto, C. Combaret, G. Garillot, G. Grenier, J-C. Ianigro, T. Kurca, I. Laktineh, B. Liu, B. Li, N. Lumb , et al. (53 additional authors not shown)

    Abstract: The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm… ▽ More

    Submitted 19 February, 2022; originally announced February 2022.

    Comments: 21 pages,23 figures

    Report number: CALICE-PUB-2022-001

  15. A 4pi time-of-flight detector for the ND280/T2K upgrade

    Authors: A. Korzenev, F. Barao, S. Bordoni, D. Breton, F. Cadoux, Y. Favre, M. Khabibullin, A. Khotyantsev, Y. Kudenko, T. Lux, J. Maalmi, P. Mermod, O. Mineev, F. Sanchez

    Abstract: ND280 is a near detector of the T2K experiment which is located in the J-PARC accelerator complex in Japan. After a decade of fruitful data-taking, ND280 is scheduled for upgrade. The time-of-flight (ToF) detector, which is described in this article, is one of three new detectors that will be installed in the basket of ND280. The ToF detector has a modular structure. Each module represents an arra… ▽ More

    Submitted 25 December, 2021; v1 submitted 7 September, 2021; originally announced September 2021.

    Comments: 9 pages, 5 figures

    Journal ref: JINST 17 (2022) 01, P01016

  16. High resolution MCP-PMT Readout Using Transmission Lines

    Authors: M. Follin, R. Chyzh, C. -H. Sung, D. Breton, J. Maalmi, T. Chaminade, E. Delagnes, K. Schäfers, C. Weinheimer, D. Yvon, V. Sharyy

    Abstract: We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection modul… ▽ More

    Submitted 25 November, 2021; v1 submitted 7 August, 2021; originally announced August 2021.

    Comments: Accepted by Nuclear Instruments and Methods in Physics Research Section A

  17. Radioactivity control strategy for the JUNO detector

    Authors: JUNO collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Fengpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Andrej Babic, Wander Baldini, Andrea Barresi, Davide Basilico, Eric Baussan, Marco Bellato, Antonio Bergnoli, Thilo Birkenfeld, Sylvie Blin , et al. (578 additional authors not shown)

    Abstract: JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula… ▽ More

    Submitted 13 October, 2021; v1 submitted 8 July, 2021; originally announced July 2021.

    Comments: 35 pages, 12 figures

  18. arXiv:2103.16900  [pdf, other

    physics.ins-det

    The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS

    Authors: JUNO Collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Fengpeng An, Guangpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Andrej Babic, Wander Baldini, Andrea Barresi, Davide Basilico, Eric Baussan, Marco Bellato, Antonio Bergnoli, Thilo Birkenfeld , et al. (582 additional authors not shown)

    Abstract: The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of… ▽ More

    Submitted 31 March, 2021; originally announced March 2021.

    Comments: 32 pages, 22 figures

  19. arXiv:2102.11538  [pdf, other

    physics.ins-det hep-ex

    Mass production and characterization of 3-inch PMTs for the JUNO experiment

    Authors: Chuanya Cao, Jilei Xu, Miao He, Angel Abusleme, Mathieu Bongrand, Clément Bordereau, Dominique Breton, Anatael Cabrera, Agustin Campeny, Cédric Cerna, Haoqiang Chen, Po-An Chen, Gérard Claverie, Selma Conforti Di Lorenzo, Christophe De La Taille, Frédéric Druillole, Amélie Fournier, Marco Grassi, Xiaofei Gu, Michael Haacke, Yang Han, Patrick Hellmuth, Yuekun Heng, Rafael Herrera, Yee Hsiung , et al. (42 additional authors not shown)

    Abstract: 26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was perf… ▽ More

    Submitted 26 February, 2021; v1 submitted 23 February, 2021; originally announced February 2021.

  20. arXiv:2011.06405  [pdf, other

    physics.ins-det hep-ex

    Calibration Strategy of the JUNO Experiment

    Authors: JUNO collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Muhammad Akram, Fengpeng An, Guangpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Andrej Babic, Wander Baldini, Andrea Barresi, Eric Baussan, Marco Bellato, Antonio Bergnoli, Enrico Bernieri, Thilo Birkenfeld , et al. (571 additional authors not shown)

    Abstract: We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca… ▽ More

    Submitted 20 January, 2021; v1 submitted 12 November, 2020; originally announced November 2020.

  21. arXiv:2008.11556  [pdf, other

    physics.ins-det hep-ex

    Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC

    Authors: C. Abellán Beteta, A. Alfonso Albero, Y. Amhis, S. Barsuk, C. Beigbeder-Beau, I. Belyaev, R. Bonnefoy, D. Breton, O. Callot, M. Calvo Gomez, A. Camboni, H. Chanal, D. Charlet, M. Chefdeville, V. Coco, E. Cogneras, A. Comerma-Montells, S. Coquereau, O. Deschamps, F. Domingo Bonal, C. Drancourt, O. Duarte, N. Dumont Dayot, R. Dzhelyadin, V. Egorychev , et al. (62 additional authors not shown)

    Abstract: The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de… ▽ More

    Submitted 26 August, 2020; originally announced August 2020.

    Comments: All figures and tables, along with any supplementary material and additional information, are available at http://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-DP-2020-001.html (LHCb public pages)

    Report number: CERN-LHCb-DP-2020-001

  22. arXiv:2006.14855  [pdf

    physics.ins-det physics.med-ph

    Design study of a scintronic crystal targeting tens of picoseconds time resolution for gamma ray imaging: the ClearMind detector

    Authors: D. Yvon, V. Sharyy, M. Follin, J-P Bard, D. Breton, J. Maalmi, C. Morel, E. Delagnes

    Abstract: We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating crystal with an efficient photocathode directly deposited on it. With an index of refraction higher for the photocathode than for the crystal, this d… ▽ More

    Submitted 26 June, 2020; originally announced June 2020.

    Comments: Accepted in Journal of Instrumentation : JINST_054P_0320

  23. arXiv:2006.11760  [pdf, other

    hep-ex hep-ph physics.ins-det

    Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

    Authors: JUNO collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Sebastiano Aiello, Muhammad Akram, Nawab Ali, Fengpeng An, Guangpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Andrej Babic, Wander Baldini, Andrea Barresi, Eric Baussan, Marco Bellato, Antonio Bergnoli, Enrico Bernieri, David Biare , et al. (572 additional authors not shown)

    Abstract: The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s… ▽ More

    Submitted 21 June, 2020; originally announced June 2020.

    Comments: 29 pages, 14 plots, 7 tables

  24. arXiv:2005.08745  [pdf, other

    physics.ins-det hep-ex nucl-ex

    TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

    Authors: JUNO Collaboration, Angel Abusleme, Thomas Adam, Shakeel Ahmad, Sebastiano Aiello, Muhammad Akram, Nawab Ali, Fengpeng An, Guangpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, Tatiana Antoshkina, Burin Asavapibhop, João Pedro Athayde Marcondes de André, Didier Auguste, Andrej Babic, Wander Baldini, Andrea Barresi, Eric Baussan, Marco Bellato, Antonio Bergnoli, Enrico Bernieri, David Biare , et al. (568 additional authors not shown)

    Abstract: The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re… ▽ More

    Submitted 18 May, 2020; originally announced May 2020.

    Comments: 134 pages, 114 figures

  25. arXiv:2004.02972  [pdf, other

    physics.ins-det hep-ex

    Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype

    Authors: D. Boumediene, A. **ault, M. Tytgat, B. Bilki, D. Northacker, Y. Onel, G. Cho, D-W. Kim, S. C. Lee, W. Park, S. Vallecorsa, Y. Deguchi, K. Kawagoe, Y. Miura, R. Mori, I. Sekiya, T. Suehara, T. Yoshioka, L. Caponetto, C. Combaret, R. Ete G. Garillot, G. Grenier, J-C. Ianigro, T. Kurca, I. Laktineh , et al. (65 additional authors not shown)

    Abstract: The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines… ▽ More

    Submitted 6 April, 2020; originally announced April 2020.

    Report number: CALICE-PUB-2020-001

  26. arXiv:2002.09556  [pdf, other

    physics.ins-det hep-ex

    CALICE SiW ECAL -- Development and performance of a highly compact digital readout system

    Authors: D. Breton, A. Irles, J. Jeglot, J. Maalmi, R. Pöschl, D. Zerwas

    Abstract: A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL of the International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International Linear Collider. Prototypes for this type of detector are developed within the CALICE Collaboration. During the last year a highly compact digital readout sys… ▽ More

    Submitted 30 March, 2020; v1 submitted 21 February, 2020; originally announced February 2020.

    Comments: Talk presented at the International Workshop on Future Linear Colliders (LCWS2019), Sendai, Japan, 28 October-1 November, 2019, C19-10-28, and the International Conference on Calorimetry at the High Energy Frontier (CHEF 2019) Fukuoka, Japan, 25 November-29 November, 2019, C19-11-25.3

  27. arXiv:2002.08722  [pdf, other

    physics.ins-det hep-ex

    SND@LHC

    Authors: SHiP Collaboration, C. Ahdida, A. Akmete, R. Albanese, A. Alexandrov, M. Andreini, A. Anokhina, S. Aoki, G. Arduini, E. Atkin, N. Azorskiy, J. J. Back, A. Bagulya, F. Baaltasar Dos Santos, A. Baranov, F. Bardou, G. J. Barker, M. Battistin, J. Bauche, A. Bay, V. Bayliss, G. Bencivenni, A. Y. Berdnikov, Y. A. Berdnikov, M. Bertani , et al. (319 additional authors not shown)

    Abstract: We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1)… ▽ More

    Submitted 20 February, 2020; originally announced February 2020.

    Comments: Letter of Intent

    Report number: CERN-LHCC-2020-002, LHCC-I-035

  28. Fast and Efficient Detection of 511 keV Photons using Cherenkov Light in PbF$_2$ Crystal coupled to a MCP-PMT and SAMPIC Digitization Module

    Authors: C. Canot, M. Alokhina, P. Abbon, J. P. Bard, D. Breton, E. Delagnes, J. Maalmi, G. Tauzin, D. Yvon, V. Sharyy

    Abstract: We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT XP85012. Amplified PMT signals are digitized by the SAMPIC module with high readout rate, up to $10^5$ events/s, and a negligible contribution to the time resol… ▽ More

    Submitted 14 November, 2019; v1 submitted 13 September, 2019; originally announced September 2019.

    Comments: Accepted by JINST

    Journal ref: Journal of Instrumentation, 14, P1200 (2019)

  29. arXiv:1908.02859  [pdf, other

    physics.ins-det hep-ex

    Neutrino Physics with an Opaque Detector

    Authors: A. Cabrera, A. Abusleme, J. dos Anjos, T. J. C. Bezerra, M. Bongrand, C. Bourgeois, D. Breton, C. Buck, J. Busto, E. Calvo, E. Chauveau, M. Chen, P. Chimenti, F. Dal Corso, G. De Conto, S. Dusini, G. Fiorentini, C. Frigerio Martins, A. Givaudan, P. Govoni, B. Gramlich, M. Grassi, Y. Han, J. Hartnell, C. Hugon , et al. (37 additional authors not shown)

    Abstract: In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the convention… ▽ More

    Submitted 6 January, 2022; v1 submitted 7 August, 2019; originally announced August 2019.

    Comments: 9 pages, 4 figures

    Journal ref: Communications Physics 4, 273 (2021)

  30. arXiv:1904.06178  [pdf, other

    physics.ins-det hep-ex physics.acc-ph

    Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment

    Authors: F. M. Addesa, L. Burmistrov, D. Breton, G. Cavoto, V. Chaumat, S. Dubos, L. Esposito, F. Galluccio, M. Garattini, F. Iacoangeli, J. Maalmi, D. Mirarchi, A. Natochii, V. Puill, R. Rossi, W. Scandale, S. Montesano, A. Stocchi

    Abstract: The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on… ▽ More

    Submitted 12 April, 2019; originally announced April 2019.

    Comments: 25 pages, 14 figures

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 946 (2019), p. 162513. issn: 0168-9002

  31. arXiv:1902.06161  [pdf, other

    physics.ins-det hep-ex

    Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype

    Authors: CALICE Collaboration, G. Eigen, T. Price, N. K. Watson, A. Winter, Y. Do, A. Khan, D. Kim, G. C. Blazey, A. Dyshkant, K. Francis, V. Zutshi, K. Kawagoe, Y. Miura, R. Mori, I. Sekiya, T. Suehara, T. Yoshioka, J. Apostolakis, J. Giraud, D. Grondin, J. -Y. Hostachy, O. Bach, V. Bocharnikov, E. Brianne , et al. (81 additional authors not shown)

    Abstract: A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorith… ▽ More

    Submitted 18 September, 2019; v1 submitted 16 February, 2019; originally announced February 2019.

    Comments: 21 pages, 21 figures

    Report number: CALICE-PUB-2019-002

    Journal ref: Nucl.Instrum.Meth. A937 (2019) 41-52

  32. Plastic scintillator detector with the readout based on an array of large-area SiPMs for the ND280/T2K upgrade and SHiP experiments

    Authors: A. Korzenev, C. Betancourt, A. Blondel, D. Breton, A. Datwyler, D. Gascon, S. Gomez, M. Khabibullin, Y. Kudenko, J. Maalmi, P. Mermod, E. Noah, N. Serra, D. Sgalaberna, B. Storaci

    Abstract: Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle identification via time-of-flight measurements. Scintillation light is collected by photosensors coupled to both ends of every bar. In this article, we present our s… ▽ More

    Submitted 23 January, 2019; originally announced January 2019.

    Comments: Presented at PD18 in Tokyo on Nov 27 2018, https://www-conf.kek.jp/PD18/PD18conf/Overview.html

    Report number: JPS Conf. Proc. 27, 011005 (2019)

  33. Calorimeter development for the SuperNEMO double beta decay experiment

    Authors: A. S. Barabash, A. Basharina-Freshville, S. Blot, M. Bongrand, Ch. Bourgeois, D. Breton, V. Brudanin, H. Burešovà, J. Busto, A. J. Caffrey, S. Calvez, M. Cascella, C. Cerna, J. P. Cesar, E. Chauveau, A. Chopra, G. Claverie, S. De Capua, F. Delalee, D. Duchesneau, V. Egorov, G. Eurin, J. J. Evans, L. Fajt, D. Filosofov , et al. (73 additional authors not shown)

    Abstract: SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main… ▽ More

    Submitted 21 July, 2017; originally announced July 2017.

  34. arXiv:1703.03612  [pdf, other

    physics.ins-det hep-ex

    The active muon shield in the SHiP experiment

    Authors: SHiP collaboration, A. Akmete, A. Alexandrov, A. Anokhina, S. Aoki, E. Atkin, N. Azorskiy, J. J. Back, A. Bagulya, A. Baranov, G. J. Barker, A. Bay, V. Bayliss, G. Bencivenni, A. Y. Berdnikov, Y. A. Berdnikov, M. Bertani, C. Betancourt, I. Bezshyiko, O. Bezshyyko, D. Bick, S. Bieschke, A. Blanco, J. Boehm, M. Bogomilov , et al. (207 additional authors not shown)

    Abstract: The SHiP experiment is designed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. An essential task for the experiment is to keep the Standard Model background level to less than 0.1 event after $2\times 10^{20}$ protons on target. In the beam dump, around $10^{11}$ muons will be produced per second. The mu… ▽ More

    Submitted 18 May, 2017; v1 submitted 10 March, 2017; originally announced March 2017.

    Comments: 8 pages, 5 figures; added clarifications to the penalty function and emphasized that we care about neutrino interactions in the air

    Journal ref: 2017_JINST_12_P05011

  35. arXiv:1610.05667  [pdf, other

    physics.ins-det

    Study of timing characteristics of a 3 m long plastic scintillator counter using waveform digitizers

    Authors: A. Blondel, D. Breton, A. Dubreuil, A. Khotyantsev, A. Korzenev, J. Maalmi, A. Mefodev, P. Mermod, E. Noah

    Abstract: A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out at both ends by photomultiplier tubes whose pulse shapes were recorded by waveform digitizers. Results obtained with the WAVECATCHER and SAMPIC digitizers are… ▽ More

    Submitted 4 August, 2017; v1 submitted 18 October, 2016; originally announced October 2016.

  36. arXiv:1604.02385  [pdf, other

    physics.ins-det hep-ex

    Measurements of timing resolution of ultra-fast silicon detectors with the SAMPIC waveform digitizer

    Authors: Dominique Breton, Victor De Cacqueray, Éric Delagnes, Hervé Grabas, Jihane Maalmi, Nicola Minafra, Christophe Royon, Matthias Saimpert

    Abstract: The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to imp… ▽ More

    Submitted 11 August, 2016; v1 submitted 8 April, 2016; originally announced April 2016.

    Comments: 31 pages, 15 figures, accepted by Nuclear Inst. and Methods in Physics Research, A

  37. arXiv:1504.04956  [pdf, other

    physics.ins-det hep-ex

    A facility to Search for Hidden Particles (SHiP) at the CERN SPS

    Authors: SHiP Collaboration, M. Anelli, S. Aoki, G. Arduini, J. J. Back, A. Bagulya, W. Baldini, A. Baranov, G. J. Barker, S. Barsuk, M. Battistin, J. Bauche, A. Bay, V. Bayliss, L. Bellagamba, G. Bencivenni, M. Bertani, O. Bezshyyko, D. Bick, N. Bingefors, A. Blondel, M. Bogomilov, A. Boyarsky, D. Bonacorsi, D. Bondarenko , et al. (211 additional authors not shown)

    Abstract: A new general purpose fixed target facility is proposed at the CERN SPS accelerator which is aimed at exploring the domain of hidden particles and make measurements with tau neutrinos. Hidden particles are predicted by a large number of models beyond the Standard Model. The high intensity of the SPS 400~GeV beam allows probing a wide variety of models containing light long-lived exotic particles w… ▽ More

    Submitted 20 April, 2015; originally announced April 2015.

    Comments: Technical Proposal

    Report number: CERN-SPSC-2015-016, SPSC-P-350, 8 April 2015

  38. arXiv:1306.5655  [pdf, other

    physics.ins-det hep-ex

    SuperB Technical Design Report

    Authors: SuperB Collaboration, M. Baszczyk, P. Dorosz, J. Kolodziej, W. Kucewicz, M. Sapor, A. Jeremie, E. Grauges Pous, G. E. Bruno, G. De Robertis, D. Diacono, G. Donvito, P. Fusco, F. Gargano, F. Giordano, F. Loddo, F. Loparco, G. P. Maggi, V. Manzari, M. N. Mazziotta, E. Nappi, A. Palano, B. Santeramo, I. Sgura, L. Silvestris , et al. (384 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch… ▽ More

    Submitted 24 June, 2013; originally announced June 2013.

    Comments: 495 pages

    Report number: INFN-13-01/PI, LAL 13-01, SLAC-R-1003

  39. arXiv:1005.0343  [pdf, ps, other

    physics.ins-det hep-ex

    Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

    Authors: J. Argyriades, R. Arnold, C. Augier, J. Baker, A. S. Barabash, A. Basharina-Freshville, M. Bongrand, C. Bourgeois, D. Breton, M. Briére, G. Broudin-Bay, V. B. Brudanin, A. J. Caffrey, S. Cebrián, A. Chapon, E. Chauveau, Th. Dafni, J. Díaz, D. Durand, V. G. Egorov, J. J. Evans, R. Flack, K-I. Fushima, I. G. Irastorza, X. Garrido , et al. (64 additional authors not shown)

    Abstract: The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the backg… ▽ More

    Submitted 3 May, 2010; originally announced May 2010.

    Comments: 24 pages, submitted to N.I.M. A