-
The Belle II Detector Upgrades Framework Conceptual Design Report
Authors:
H. Aihara,
A. Aloisio,
D. P. Auguste,
M. Aversano,
M. Babeluk,
S. Bahinipati,
Sw. Banerjee,
M. Barbero,
J. Baudot,
A. Beaubien,
F. Becherer,
T. Bergauer,
F. U. Bernlochner.,
V. Bertacchi,
G. Bertolone,
C. Bespin,
M. Bessner,
S. Bettarini,
A. J. Bevan,
B. Bhuyan,
M. Bona,
J. F. Bonis,
J. Borah,
F. Bosi,
R. Boudagga
, et al. (186 additional authors not shown)
Abstract:
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit…
▽ More
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.
△ Less
Submitted 4 July, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
Photon Reconstruction in the Belle II Calorimeter Using Graph Neural Networks
Authors:
F. Wemmer,
I. Haide,
J. Eppelt,
T. Ferber,
A. Beaubien,
P. Branchini,
M. Campajola,
C. Cecchi,
P. Cheema,
G. De Nardo,
C. Hearty,
A. Kuzmin,
S. Longo,
E. Manoni,
F. Meier,
M. Merola,
K. Miyabayashi,
S. Moneta,
M. Remnev,
J. M. Roney,
J. -G. Shiu,
B. Shwartz,
Y. Unno,
R. van Tonder,
R. Volpe
Abstract:
We present the study of a fuzzy clustering algorithm for the Belle II electromagnetic calorimeter using Graph Neural Networks. We use a realistic detector simulation including simulated beam backgrounds and focus on the reconstruction of both isolated and overlap** photons. We find significant improvements of the energy resolution compared to the currently used reconstruction algorithm for both…
▽ More
We present the study of a fuzzy clustering algorithm for the Belle II electromagnetic calorimeter using Graph Neural Networks. We use a realistic detector simulation including simulated beam backgrounds and focus on the reconstruction of both isolated and overlap** photons. We find significant improvements of the energy resolution compared to the currently used reconstruction algorithm for both isolated and overlap** photons of more than 30% for photons with energies E < 0.5 GeV and high levels of beam backgrounds. Overall, the GNN reconstruction improves the resolution and reduces the tails of the reconstructed energy distribution and therefore is a promising option for the upcoming high luminosity running of Belle II.
△ Less
Submitted 3 March, 2024; v1 submitted 7 June, 2023;
originally announced June 2023.
-
Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector
Authors:
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
A. P. Caricato,
G. Chiodini,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
P. Gianotti,
S. Ivanov,
Sv. Ivanov,
V. Kozhuharov,
E. Leonardi,
E. Long,
M. Martino,
I. Oceano,
F. Oliva
, et al. (13 additional authors not shown)
Abstract:
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection…
▽ More
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.
△ Less
Submitted 7 November, 2022; v1 submitted 26 October, 2022;
originally announced October 2022.
-
Dark sector studies with the PADME experiment
Authors:
Anna Paola Caricato,
Maurizio Martino,
Isabella Oceano,
Federica Oliva,
Stefania Spagnolo,
Gabriele Chiodini,
Fabio Bossi,
Riccardo De Sangro,
Claudio Di Giulio,
Danilo Domenici,
Giuseppe Finocchiaro,
Luca Gennaro Foggetta,
Marco Garattini,
Andrea Ghigo,
Federica Giacchino,
Paola Gianotti,
Tommaso Spadaro,
Eletuerio Spiriti,
Clara Taruggi,
Elisabetta Vilucchi,
Venelin Kozhuharov,
Simeon Ivanov,
Svetoslav Ivanov,
Radoslav Simeonov,
Georgi Georgiev
, et al. (13 additional authors not shown)
Abstract:
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches f…
▽ More
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches for new particles such as long lived Axion-Like-Particles, protophobic X bosons and Dark Higgs. This talk illustrated the scientific program of the experiment and its first physics results. In particular, the measurement of the cross-section of the SM process $e^+e^-\rightarrow γγ$ at $\sqrt{s}$=21 MeV was shown.
△ Less
Submitted 1 May, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
Commissioning of the PADME experiment with a positron beam
Authors:
P. Albicocco,
R. Assiro,
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
E. Capitolo,
C. Capoccia,
A. P. Caricato,
S. Ceravolo,
G. Chiodini,
G. Corradi,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
S. Fiore,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
A. Ghigo,
P. Gianotti
, et al. (31 additional authors not shown)
Abstract:
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ posi…
▽ More
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target.
This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.
△ Less
Submitted 20 July, 2022; v1 submitted 6 May, 2022;
originally announced May 2022.
-
Characterisation and performance of the PADME electromagnetic calorimeter
Authors:
P. Albicocco,
J. Alexander,
F. Bossi,
P. Branchini,
B. Buonomo,
C. Capoccia,
E. Capitolo,
G. Chiodini,
A. P. Caricato,
R. de Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
S. Fiore,
L. G. Foggetta,
A. Frankenthal,
G. Georgiev,
A. Ghigo,
F. Giacchino,
P. Gianotti,
S. Ivanov,
V. Kozhuharov,
E. Leonardi,
B. Liberti
, et al. (20 additional authors not shown)
Abstract:
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring t…
▽ More
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $γ$. The missing four-momentum carried away by the $A'$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADME's electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
△ Less
Submitted 21 October, 2020; v1 submitted 28 July, 2020;
originally announced July 2020.
-
The Monitoring System of the End-Cap Calorimeter in the Belle II experiment
Authors:
V. Izzo,
A. Aloisio,
F. Ameli,
A. Anastasio,
P. Branchini,
F. Di Capua,
R. Giordano,
A. Kuzmin,
K. Miyabayashi,
I. Nakamura,
M. Nakao,
G. Tortone,
S. Uehara
Abstract:
The Belle II experiment is presently in phase-2 operation at the SuperKEKB electron-positron collider in KEK (Tsukuba, Japan). The detector is an upgrade of the Belle experiment at the KEKB collider and it is optimized for the study of rare B decays, being also sensitive to signals of New Physics beyond the Standard Model. The Electromagnetic Calorimeter (ECL) is based on CsI(Tl) scintillation cry…
▽ More
The Belle II experiment is presently in phase-2 operation at the SuperKEKB electron-positron collider in KEK (Tsukuba, Japan). The detector is an upgrade of the Belle experiment at the KEKB collider and it is optimized for the study of rare B decays, being also sensitive to signals of New Physics beyond the Standard Model. The Electromagnetic Calorimeter (ECL) is based on CsI(Tl) scintillation crystals. It splits in a barrel and two annular end-cap regions, these latter named Forward and Backward, according to the asymmetric design of the collider. CsI(Tl) crystals deliver a high light output at an affordable cost, however their yield changes with temperature and can be permanently damaged by humidity, due to the strong chemical affinity for moisture. Each ECL region is then equipped with thermistors and humidity probes to monitor environmental data. While sensors and cabling have been inherited from the original Belle design, the ECL monitoring system has been fully redesigned. In this paper, we present hardware and software architecture deployed for the 2112 CsI(Tl) crystals arranged in the Forward and Backward end-caps. Single-Board Computers (SBCs) have been designed ad-hoc for embedded applications. For sensor read-out, a data-acquisition system based on 24-bit ADCs with local processing capability has been realized and interfaced with the SBCs. EPICS applications send data across the Local Area Network for remote control and display.
△ Less
Submitted 1 July, 2018;
originally announced July 2018.
-
First Measurements of Beam Backgrounds at SuperKEKB
Authors:
P. M. Lewis,
I. Jaegle,
H. Nakayama,
A. Aloisio,
F. Ameli,
M. Barrett,
A. Beaulieu,
L. Bosisio,
P. Branchini,
T. E. Browder,
A. Budano,
G. Cautero,
C. Cecchi,
Y. -T. Chen,
K. -N. Chu,
D. Cinabro,
P. Cristaudo,
S. de Jong,
R. de Sangro,
G. Finocchiaro,
J. Flanagan,
Y. Funakoshi,
M. Gabriel,
R. Giordano,
D. Giuressi
, et al. (45 additional authors not shown)
Abstract:
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, d…
▽ More
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam-gas, Touschek, beam-dust, and injection backgrounds. We do not observe significant synchrotron radiation, as expected. Measured LER beam-gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam-gas backgrounds are on on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1-2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Measurement of the neutron detection efficiency of a 80% absorber - 20% scintillating fibers calorimeter
Authors:
M. Anelli,
S. Bertolucci,
C. Bini,
P. Branchini,
G. Corradi,
C. Curceanu,
G. De Zorzi,
A. Di Domenico,
B. Di Micco,
A. Ferrari,
S. Fiore,
P. Gauzzi,
S. Giovannella,
F. Happacher,
M. Iliescu,
A. Luca',
M. Martini,
S. Miscetti,
F. Nguyen,
A. Passeri,
A. Prokofiev,
I. Sarra,
B. Sciascia,
F. Sirghi,
D. Tagnani
Abstract:
The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
△ Less
Submitted 21 September, 2010; v1 submitted 13 April, 2010;
originally announced April 2010.
-
Technical Design Report of the Inner Tracker for the KLOE-2 experiment
Authors:
KLOE-2 Collaboration,
:,
F. Archilli,
D. Badoni,
D. Babusci,
G. Bencivenni,
C. Bini,
C. Bloise,
V. Bocci,
F. Bossi,
P. Branchini,
A. Budano,
S. A. Bulychjev,
P. Campana,
G. Capon,
F. Ceradini,
P. Ciambrone,
E. Czerwinski,
E. Danè,
E. De Lucia,
G. De Robertis,
A. De Santis,
G. De Zorzi,
A. Di Domenico,
C. Di Donato
, et al. (59 additional authors not shown)
Abstract:
The technical design report of the Inner Tracker for the KLOE-2 experiment is presented
The technical design report of the Inner Tracker for the KLOE-2 experiment is presented
△ Less
Submitted 12 February, 2010;
originally announced February 2010.
-
Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters
Authors:
M. Anelli,
S. Bertolucci,
C. Bini,
P. Branchini,
G. Corradi,
C. Curceanu,
G. De Zorzi,
A. Di Domenico,
B. Di Micco,
A. Ferrari,
S. Fiore,
P. Gauzzi,
S. Giovannella,
F. Happacher,
M. Ilieascu,
A. Luca',
M. Martini,
S. Miscetti,
F. Nguyen,
A. Passeri,
A. Prokofiev,
I. Sarra,
B. Sciascia,
F. Sirghi,
D. Tagnani
Abstract:
We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. %To check our method, we measured also the neutron %detection efficiency of a 5 cm thick NE110 scintillat…
▽ More
We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. %To check our method, we measured also the neutron %detection efficiency of a 5 cm thick NE110 scintillator. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters.
△ Less
Submitted 5 June, 2009;
originally announced June 2009.