Quantum Frequency Mixing using an NV Diamond Microscope
Authors:
Samuel J. Karlson,
Pauli Kehayias,
Jennifer M. Schloss,
Andrew C. Maccabe,
David F. Phillips,
Guoqing Wang,
Paola Cappellaro,
Danielle A. Braje
Abstract:
Wide-field magnetic microscopy using nitrogen-vacancy (NV) centers in diamond can yield high-quality magnetic images of DC and AC magnetic fields. The unique combination of micron-scale spatial resolution of scalar or vector fields at room temperature and parallel camera readout make this an appealing technique for applications in biology, geology, condensed-matter physics, and electronics. Howeve…
▽ More
Wide-field magnetic microscopy using nitrogen-vacancy (NV) centers in diamond can yield high-quality magnetic images of DC and AC magnetic fields. The unique combination of micron-scale spatial resolution of scalar or vector fields at room temperature and parallel camera readout make this an appealing technique for applications in biology, geology, condensed-matter physics, and electronics. However, while NV magnetic microscopy has achieved great success in these areas, historically the accessible frequency range has been limited. In this paper, we overcome this limitation by implementing the recently developed technique of quantum frequency mixing. With this approach, we generate wide-field magnetic images of test structures driven by alternating currents up to 70 MHz, well outside the reach of DC and Rabi magnetometry methods. With further improvements, this approach could find utility in hyperspectral imaging for electronics power spectrum analysis, electronics diagnostics and troubleshooting, and quantum computing hardware validation.
△ Less
Submitted 9 July, 2024;
originally announced July 2024.
-
Optical Atomic Clock Interrogation Via an Integrated Spiral Cavity Laser
Authors:
William Loh,
David Reens,
Dave Kharas,
Alkesh Sumant,
Connor Belanger,
Ryan T. Maxson,
Alexander Medeiros,
William Setzer,
Dodd Gray,
Kyle DeBry,
Colin D. Bruzewicz,
Jason Plant,
John Liddell,
Gavin N. West,
Sagar Doshi,
Matthew Roychowdhury,
May Kim,
Danielle Braje,
Paul W. Juodawlkis,
John Chiaverini,
Robert McConnell
Abstract:
Optical atomic clocks have demonstrated revolutionary advances in precision timekee**, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to clock portability stems from the many obstacles not only in miniaturizing the underlying components of the clock $-$ namely the ultrastable laser, the frequency co…
▽ More
Optical atomic clocks have demonstrated revolutionary advances in precision timekee**, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to clock portability stems from the many obstacles not only in miniaturizing the underlying components of the clock $-$ namely the ultrastable laser, the frequency comb, and the atomic reference itself $-$ but also in making the clock resilient to environmental fluctuations. Photonic integration offers one compelling solution to simultaneously address the problems of miniaturization and ruggedization, but brings with it a new set of challenges in recreating the functionality of an optical clock using chip-scale building blocks. The clock laser used for atom interrogation is one particular point of uncertainty, as the performance of the meticulously-engineered bulk-cavity stabilized lasers would be exceptionally difficult to transfer to chip. Here we demonstrate that a chip-integrated ultrahigh quality factor (Q) spiral cavity, when interfaced with a 1348 nm seed laser, reaches a fractional frequency instability of $7.5 \times 10^{-14}$, meeting the stability requirements for interrogating the narrow-linewidth transition of $^{88}$Sr$^+$ upon frequency doubling to 674 nm. In addition to achieving the record for laser stability on chip, we use this laser to showcase the operation of a Sr-ion clock with short-term instability averaging down as $3.9 \times 10^{-14} / \sqrtτ$, where $τ$ is the averaging time. Our demonstration of an optical atomic clock interrogated by an integrated spiral cavity laser opens the door for future advanced clock systems to be entirely constructed using lightweight, portable, and mass-manufacturable integrated optics and electronics.
△ Less
Submitted 19 March, 2024;
originally announced March 2024.
-
Ferrimagnetic Oscillator Magnetometer
Authors:
John F. Barry,
Reed A. Irion,
Matthew H. Steinecker,
Daniel K. Freeman,
Jessica J. Kedziora,
Reginald G. Wilcox,
Danielle A. Braje
Abstract:
Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. Th…
▽ More
Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. The device exhibits a fixed, calibration-free response governed by the electron gyromagnetic ratio. Exchange narrowing in the ferrimagnetic material produces sub-MHz transition linewidths despite the high unpaired spin density ($\sim 10^{22}$ cm$^{-3}$). The magnetometer achieves a minimum sensitivity of 100 fT/$\sqrt{\text{Hz}}$ to AC magnetic fields of unknown phase and a sensitivity below 200 fT/$\sqrt{\text{Hz}}$ over a bandwidth $\gtrsim \! 1$ MHz. By encoding magnetic field in frequency rather than amplitude, the device provides a dynamic range in excess of 1 mT. The passive, thermal initialization of the sensor's quantum state requires only a magnetic bias field, greatly reducing power requirements compared to laser-initialized quantum sensors. With additional development, this device promises to be a leading candidate for high-performance magnetometry outside the laboratory, and the oscillator architecture is expected to provide advantages across a wide range of sensing platforms.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Sensitive AC and DC Magnetometry with Nitrogen-Vacancy Center Ensembles in Diamond
Authors:
John F. Barry,
Matthew H. Steinecker,
Scott T. Alsid,
Jonah Majumder,
Linh M. Pham,
Michael F. O'Keefe,
Danielle A. Braje
Abstract:
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature a…
▽ More
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review~\cite{barry2020sensitivity} suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn echo magnetometry sequences for broadband and narrowband magnetometry respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the NVs to magnetic field. The magnetometer realizes a broadband \textcolor{mhsnew}{near-}DC sensitivity $\sim 460$~fT$\cdot$s$^{1/2}$ and a narrowband AC sensitivity $\sim 210$~fT$\cdot$s$^{1/2}$. We describe the experimental setup in detail and highlight potential paths for future improvement.
△ Less
Submitted 10 May, 2023;
originally announced May 2023.
-
Large-scale optical characterization of solid-state quantum emitters
Authors:
Madison Sutula,
Ian Christen,
Eric Bersin,
Michael P. Walsh,
Kevin C. Chen,
Justin Mallek,
Alexander Melville,
Michael Titze,
Edward S. Bielejec,
Scott Hamilton,
Danielle Braje,
P. Benjamin Dixon,
Dirk R. Englund
Abstract:
Solid-state quantum emitters have emerged as a leading quantum memory for quantum networking applications. However, standard optical characterization techniques are neither efficient nor repeatable at scale. In this work, we introduce and demonstrate spectroscopic techniques that enable large-scale, automated characterization of color centers. We first demonstrate the ability to track color center…
▽ More
Solid-state quantum emitters have emerged as a leading quantum memory for quantum networking applications. However, standard optical characterization techniques are neither efficient nor repeatable at scale. In this work, we introduce and demonstrate spectroscopic techniques that enable large-scale, automated characterization of color centers. We first demonstrate the ability to track color centers by registering them to a fabricated machine-readable global coordinate system, enabling systematic comparison of the same color center sites over many experiments. We then implement resonant photoluminescence excitation in a widefield cryogenic microscope to parallelize resonant spectroscopy, achieving two orders of magnitude speed-up over confocal microscopy. Finally, we demonstrate automated chip-scale characterization of color centers and devices at room temperature, imaging thousands of microscope fields of view. These tools will enable accelerated identification of useful quantum emitters at chip-scale, enabling advances in scaling up color center platforms for quantum information applications, materials science, and device design and characterization.
△ Less
Submitted 24 October, 2022;
originally announced October 2022.
-
An integrated photonic engine for programmable atomic control
Authors:
Ian Christen,
Madison Sutula,
Thomas Propson,
Hamed Sattari,
Gregory Choong,
Christopher Panuski,
Alexander Melville,
Justin Mallek,
Scott Hamilton,
P. Benjamin Dixon,
Adrian J. Menssen,
Danielle Braje,
Amir H. Ghadimi,
Dirk Englund
Abstract:
Solutions for scalable, high-performance optical control are important for the development of scaled atom-based quantum technologies. Modulation of many individual optical beams is central to the application of arbitrary gate and control sequences on arrays of atoms or atom-like systems. At telecom wavelengths, miniaturization of optical components via photonic integration has pushed the scale and…
▽ More
Solutions for scalable, high-performance optical control are important for the development of scaled atom-based quantum technologies. Modulation of many individual optical beams is central to the application of arbitrary gate and control sequences on arrays of atoms or atom-like systems. At telecom wavelengths, miniaturization of optical components via photonic integration has pushed the scale and performance of classical and quantum optics far beyond the limitations of bulk devices. However, these material platforms for high-speed telecom integrated photonics are not transparent at the short wavelengths required by leading atomic systems. Here, we propose and implement a scalable and reconfigurable photonic architecture for multi-channel quantum control using integrated, visible-light modulators based on thin-film lithium niobate. Our approach combines techniques in free-space optics, holography, and control theory together with a sixteen-channel integrated photonic device to stabilize temporal and cross-channel power deviations and enable precise and uniform control. Applying this device to a homogeneous constellation of silicon-vacancy artificial atoms in diamond, we present techniques to spatially and spectrally address a dynamically-selectable set of these stochastically-positioned point emitters. We anticipate that this scalable and reconfigurable optical architecture will lead to systems that could enable parallel individual programmability of large many-body atomic systems, which is a critical step towards universal quantum computation on such hardware.
△ Less
Submitted 13 August, 2022;
originally announced August 2022.
-
A Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity
Authors:
Scott T. Alsid,
Jennifer M. Schloss,
Matthew H. Steinecker,
John F. Barry,
Andrew C. Maccabe,
Guoqing Wang,
Paola Cappellaro,
Danielle A. Braje
Abstract:
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for micro…
▽ More
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/$\sqrt{\textrm{Hz}}$. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
High-Fidelity Ion State Detection Using Trap-Integrated Avalanche Photodiodes
Authors:
David Reens,
Michael Collins,
Joseph Ciampi,
Dave Kharas,
Brian F. Aull,
Kevan Donlon,
Colin D. Bruzewicz,
Bradley Felton,
Jules Stuart,
Robert J. Niffenegger,
Philip Rich,
Danielle Braje,
Kevin K. Ryu,
John Chiaverini,
Robert McConnell
Abstract:
Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at ea…
▽ More
Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trap** location. Here we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trap** chips. We detect the state of a trapped $^{88}\text{Sr}^{+}$ ion via fluorescence collection with the SPAD, achieving $99.92(1)\%$ average fidelity in 450 $μ$s, opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.
△ Less
Submitted 3 February, 2022;
originally announced February 2022.
-
Cooling of an Integrated Brillouin Laser below the Thermal Limit
Authors:
William Loh,
Dave Kharas,
Ryan Maxson,
Gavin N. West,
Alexander Medeiros,
Danielle Braje,
Paul W. Juodawlkis,
Robert McConnell
Abstract:
Photonically integrated resonators are promising as a platform for enabling ultranarrow linewidth lasers in a compact form factor. Owing to their small size, these integrated resonators suffer from thermal noise that limits the frequency stability of the optical mode to ~100 kHz. Here, we demonstrate an integrated stimulated Brillouin scattering (SBS) laser based on a large mode-volume annulus res…
▽ More
Photonically integrated resonators are promising as a platform for enabling ultranarrow linewidth lasers in a compact form factor. Owing to their small size, these integrated resonators suffer from thermal noise that limits the frequency stability of the optical mode to ~100 kHz. Here, we demonstrate an integrated stimulated Brillouin scattering (SBS) laser based on a large mode-volume annulus resonator that realizes an ultranarrow thermal-noise-limited linewidth of 270 Hz. In practice, yet narrower linewidths are required before integrated lasers can be truly useful for applications such as optical atomic clocks, quantum computing, gravitational wave detection, and precision spectroscopy. To this end, we employ a thermorefractive noise suppression technique utilizing an auxiliary laser to reduce our SBS laser linewidth to 70 Hz. This demonstration showcases the possibility of stabilizing the thermal motion of even the narrowest linewidth chip lasers to below 100 Hz, thereby opening the door to making integrated microresonators practical for the most demanding future scientific endeavors.
△ Less
Submitted 1 December, 2021;
originally announced December 2021.
-
Thermally-Polarized Solid-State Spin Sensor
Authors:
Reginald Wilcox,
Erik Eisenach,
John Barry,
Matthew Steinecker,
Michael O'Keeffe,
Dirk Englund,
Danielle Braje
Abstract:
Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically-polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optica…
▽ More
Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically-polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optical heat load. We demonstrate a solid-state sensor employing a non-optical state preparation technique, which harnesses thermal population imbalances induced by the defect's zero-field splitting. Readout is performed using the recently-demonstrated microwave cavity readout technique, resulting in a sensor architecture that is entirely non-optical and broadly applicable to all solid-state paramagnetic defects with a zero-field splitting. The implementation in this work uses Cr$^{3+}$ defects in a sapphire (Al$_2$O$_3$) crystal and a simple microwave architecture where the host crystal also serves as the high quality-factor resonator. This approach yields a near-unity filling factor and high single-spin-photon coupling, producing a magnetometer with a broadband sensitivity of 9.7 pT/$\sqrt{\text{Hz}}$.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Cavity quantum electrodynamic readout of a solid-state spin sensor
Authors:
Erik R. Eisenach,
John F. Barry,
Michael F. O'Keeffe,
Jennifer M. Schloss,
Matthew H. Steinecker,
Dirk R. Englund,
Danielle A. Braje
Abstract:
Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems w…
▽ More
Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems with substantial advantages in compactness and range of operating conditions. However, in spite of experimental progress in specific systems, solid-state spin sensors still lack a universal, high-fidelity readout technique. Here we demonstrate high-fidelity, room-temperature readout of an ensemble of nitrogen-vacancy (NV) centers via strong coupling to a dielectric microwave cavity, building on similar techniques commonly applied in cryogenic circuit cavity quantum electrodynamics. This strong collective interaction allows the spin ensemble's microwave transition to be probed directly, thereby overcoming the optical photon shot noise limitations of conventional fluorescence readout. Applying this technique to magnetometry, we show magnetic sensitivity approaching the Johnson-Nyquist noise limit of the system. This readout technique is viable for the many paramagnetic spin systems that exhibit resonances in the microwave domain. Our results pave a clear path to achieve unity readout fidelity of solid-state spin sensors through increased ensemble size, reduced spin-resonance linewidth, or improved cavity quality factor.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
A Brillouin Laser Optical Atomic Clock
Authors:
William Loh,
Jules Stuart,
David Reens,
Colin D. Bruzewicz,
Danielle Braje,
John Chiaverini,
Paul W. Juodawlkis,
Jeremy M. Sage,
Robert McConnell
Abstract:
Over the last decade, optical atomic clocks have surpassed their microwave counterparts and now offer the ability to measure time with an increase in precision of two orders of magnitude or more. This performance increase is compelling not only for enabling new science, such as geodetic measurements of the earth, searches for dark matter, and investigations into possible long-term variations of fu…
▽ More
Over the last decade, optical atomic clocks have surpassed their microwave counterparts and now offer the ability to measure time with an increase in precision of two orders of magnitude or more. This performance increase is compelling not only for enabling new science, such as geodetic measurements of the earth, searches for dark matter, and investigations into possible long-term variations of fundamental physics constants but also for revolutionizing existing technology, such as the global positioning system (GPS). A significant remaining challenge is to transition these optical clocks to non-laboratory environments, which requires the ruggedization and miniaturization of the atomic reference and clock laser along with their supporting lasers and electronics. Here, using a compact stimulated Brillouin scattering (SBS) laser to interrogate a $^8$$^8$Sr$^+$ ion, we demonstrate a promising component of a portable optical atomic clock architecture. In order to bring the stability of the SBS laser to a level suitable for clock operation, we utilize a self-referencing technique to compensate for temperature drift of the laser to within $170$ nK. Our SBS optical clock achieves a short-term stability of $3.9 \times 10^{-14}$ at $1$ s---an order of magnitude improvement over state-of-the-art microwave clocks. Based on this technology, a future GPS employing portable SBS clocks offers the potential for distance measurements with a 100-fold increase in resolution.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
Broadband loop gap resonator for nitrogen vacancy centers in diamond
Authors:
Erik Eisenach,
John Barry,
Roberto Rojas,
Linh M. Pham,
Dirk R. Englund,
Danielle Braje
Abstract:
We present an S-band tunable loop gap resonator (LGR) providing strong, homogeneous, and directionally uniform broadband microwave (MW) drive for nitrogen-vacancy (NV) ensembles. With 42 dBm of input power, the composite device provides drive field amplitudes approaching 5 G over a circular area $\gtrsim\!50$ mm$^2$ or cylindrical volume $\gtrsim\!250$ mm$^3$. The wide 80 MHz device bandwidth allo…
▽ More
We present an S-band tunable loop gap resonator (LGR) providing strong, homogeneous, and directionally uniform broadband microwave (MW) drive for nitrogen-vacancy (NV) ensembles. With 42 dBm of input power, the composite device provides drive field amplitudes approaching 5 G over a circular area $\gtrsim\!50$ mm$^2$ or cylindrical volume $\gtrsim\!250$ mm$^3$. The wide 80 MHz device bandwidth allows driving all eight NV Zeeman resonances for bias magnetic fields below 20 G. For pulsed applications the device realizes percent-scale microwave drive inhomogeneity; we measure a fractional root-mean-square inhomogeneity $σ_\text{rms}\!=\! 1.6\%$ and a peak-to-peak variation $σ_\text{pp}\!=\! 3\%$ over a circular area of 11 mm$^2$, and $σ_\text{rms} \!=\! 3.2\%$ and $σ_\text{pp}\! =\! 10.5\%$ over a larger 32 mm$^2$ circular area. We demonstrate incident MW power coupling to the LGR using multiple methodologies: a PCB-fabricated exciter antenna for deployed compact bulk sensors and an inductive coupling coil suitable for microscope-style imaging. The inductive coupling coil allows for approximately $2π$ steradian combined optical access above and below the device, ideal for envisioned and existing NV imaging and bulk sensing applications.
△ Less
Submitted 25 April, 2018;
originally announced April 2018.
-
Robust High-Dynamic-Range Vector Magnetometry via Nitrogen-Vacancy Centers in Diamond
Authors:
Hannah Clevenson,
Linh M. Pham,
Carson Teale,
Kerry Johnson,
Dirk Englund,
Danielle Braje
Abstract:
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynami…
▽ More
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynamic range; and allows for simultaneous interrogation of multiple transition frequencies. By directly detecting the resonance frequencies of NV centers aligned along each of the diamond's four tetrahedral crystallographic axes, we perform full vector reconstruction of an applied magnetic field.
△ Less
Submitted 26 February, 2018;
originally announced February 2018.
-
Analysis and mitigation of interface losses in trenched superconducting coplanar waveguide resonators
Authors:
Greg Calusine,
Alexander Melville,
Wayne Woods,
Rabindra Das,
Corey Stull,
Vlad Bolkhovsky,
Danielle Braje,
David Hover,
David K. Kim,
Xhovalin Miloshi,
Danna Rosenberg,
Arjan Sevi,
Jonilyn L. Yoder,
Eric A. Dauler,
William D. Oliver
Abstract:
Improving the performance of superconducting qubits and resonators generally results from a combination of materials and fabrication process improvements and design modifications that reduce device sensitivity to residual losses. One instance of this approach is to use trenching into the device substrate in combination with superconductors and dielectrics with low intrinsic losses to improve quali…
▽ More
Improving the performance of superconducting qubits and resonators generally results from a combination of materials and fabrication process improvements and design modifications that reduce device sensitivity to residual losses. One instance of this approach is to use trenching into the device substrate in combination with superconductors and dielectrics with low intrinsic losses to improve quality factors and coherence times. Here we demonstrate titanium nitride coplanar waveguide resonators with mean quality factors exceeding two million and controlled trenching reaching 2.2 $μ$m into the silicon substrate. Additionally, we measure sets of resonators with a range of sizes and trench depths and compare these results with finite-element simulations to demonstrate quantitative agreement with a model of interface dielectric loss. We then apply this analysis to determine the extent to which trenching can improve resonator performance.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.
-
High-sensitivity, spin-based electrometry with an ensemble of nitrogen-vacancy centers in diamond
Authors:
Edward H. Chen,
Hannah A. Clevenson,
Kerry A. Johnson,
Linh M. Pham,
Dirk R. Englund,
Philip R. Hemmer,
Danielle A. Braje
Abstract:
We demonstrate a spin-based, all-dielectric electrometer based on an ensemble of nitrogen-vacancy (NV$^-$) defects in diamond. An applied electric field causes energy level shifts symmetrically away from the NV$^-$'s degenerate triplet states via the Stark effect; this symmetry provides immunity to temperature fluctuations allowing for shot-noise-limited detection. Using an ensemble of NV$^-$s, we…
▽ More
We demonstrate a spin-based, all-dielectric electrometer based on an ensemble of nitrogen-vacancy (NV$^-$) defects in diamond. An applied electric field causes energy level shifts symmetrically away from the NV$^-$'s degenerate triplet states via the Stark effect; this symmetry provides immunity to temperature fluctuations allowing for shot-noise-limited detection. Using an ensemble of NV$^-$s, we demonstrate shot-noise limited sensitivities approaching 1 V/cm/$\sqrt{\text{Hz}}$ under ambient conditions, at low frequencies ($<$10 Hz), and over a large dynamic range (20 dB). A theoretical model for the ensemble of NV$^-$s fits well with measurements of the ground-state electric susceptibility parameter, $\langle k_\perp\rangle$. Implications of spin-based, dielectric sensors for micron-scale electric-field sensing are discussed.
△ Less
Submitted 22 March, 2017;
originally announced March 2017.
-
Broadband Magnetometry and Temperature Sensing with a Light Trap** Diamond Waveguide
Authors:
Hannah Clevenson,
Matthew E. Trusheim,
Tim Schroder,
Carson Teale,
Danielle Braje,
Dirk Englund
Abstract:
Solid-state quantum sensors are attracting wide interest because of their exceptional sensitivity at room temperature. In particular, the spin properties of individual nitrogen vacancy (NV) color centers in diamond make it an outstanding nanoscale sensor of magnetic fields, electric fields, and temperature, under ambient conditions. Recent work on ensemble NV-based magnetometers, inertial sensors,…
▽ More
Solid-state quantum sensors are attracting wide interest because of their exceptional sensitivity at room temperature. In particular, the spin properties of individual nitrogen vacancy (NV) color centers in diamond make it an outstanding nanoscale sensor of magnetic fields, electric fields, and temperature, under ambient conditions. Recent work on ensemble NV-based magnetometers, inertial sensors, and clocks have employed $N$ unentangled color centers to realize a factor of up to $\sqrt{N}$ improvement in sensitivity. However, to realize fully this signal enhancement, new techniques are required to excite efficiently and to collect fluorescence from large NV ensembles. Here, we introduce a light-trap** diamond waveguide (LTDW) geometry that enables both high fluorescence collection ($\sim20\%$) and efficient pump absorption achieving an effective path length exceeding $1$ meter in a millimeter-sized device. The LTDW enables in excess of $2\%$ conversion efficiency of pump photons into optically detected magnetic resonance (ODMR) fluorescence, a \textit{three orders of magnitude} improvement over previous single-pass geometries. This dramatic enhancement of ODMR signal enables broadband measurements of magnetic field and temperature at less than $1$ Hz, a frequency range inaccessible by dynamical decoupling techniques. We demonstrate $\sim 1~\mbox{nT}/\sqrt{\mbox{Hz}}$ magnetic field sensitivity for $0.1$ Hz to $10$ Hz and a thermal sensitivity of $\sim 400 ~μ\mbox{K}/\sqrt{\mbox{Hz}}$ and estimate a spin projection limit at $\sim 0.36$ fT/$\sqrt{\mbox{Hz}}$ and $\sim 139~\mbox{pK}/\sqrt{\mbox{Hz}}$, respectively.
△ Less
Submitted 19 June, 2014;
originally announced June 2014.