-
Proton Pencil-Beam Scanning Stereotactic Body Radiation Therapy and Hypofractionated Radiation Therapy for Thoracic Malignancies: Patterns of Practice Survey and Recommendations for Future Development from NRG Oncology and PTCOG
Authors:
Wei Liu,
Hongying Feng,
Paige A. Taylor,
Minglei Kang,
Jiajian Shen,
Jatinder Saini,
Jun Zhou,
Huan B. Giap,
Nathan Y. Yu,
Terence S. Sio,
Pranshu Mohindra,
Joe Y. Chang,
Jeffrey D. Bradley,
Ying Xiao,
Charles B. Simone II,
Liyong Lin
Abstract:
Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical organ sparing from both PBSPT and SBRT, this new delivery technique has great potential to improve the therapeutic ratio, particularly for tumors near critical…
▽ More
Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical organ sparing from both PBSPT and SBRT, this new delivery technique has great potential to improve the therapeutic ratio, particularly for tumors near critical organs. Safe and effective implementation of PBSPT SBRT/hypofractionation to treat thoracic malignancies is more challenging than the conventionally-fractionated PBSPT due to concerns of amplified uncertainties at the larger dose per fraction. NRG Oncology and Particle Therapy Cooperative Group (PTCOG) Thoracic Subcommittee surveyed US proton centers to identify practice patterns of thoracic PBSPT SBRT/hypofractionation. From these patterns, we present recommendations for future technical development of proton SBRT/hypofractionation for thoracic treatment. Amongst other points, the recommendations highlight the need for volumetric image guidance and multiple CT-based robust optimization and robustness tools to minimize further the impact of uncertainties associated with respiratory motion. Advances in direct motion analysis techniques are urgently needed to supplement current motion management techniques.
△ Less
Submitted 1 February, 2024;
originally announced February 2024.
-
Octave-spanning supercontinuum generation in a CMOS-compatible thin Si3N4 waveguide coated with highly nonlinear TeO2
Authors:
Hamidu M. Mbonde,
Neetesh Singh,
Bruno L. Segat Frare,
Milan Sinobad,
Pooya Torab Ahmadi,
Batoul Hashemi,
Dawson. B. Bonneville,
Peter Mascher,
Franz X. Kaertner,
Jonathan D. B. Bradley
Abstract:
Supercontinuum generation (SCG) is an important nonlinear optical process enabling broadband light sources for many applications, for which silicon nitride(Si3N4) has emerged as a leading on-chip platform.To achieve suitable group velocity dispersion and high confinement for broadband SCG the Si3N4 waveguide layer used is typically thick (>~700 nm), which can lead to high stress and cracks unless…
▽ More
Supercontinuum generation (SCG) is an important nonlinear optical process enabling broadband light sources for many applications, for which silicon nitride(Si3N4) has emerged as a leading on-chip platform.To achieve suitable group velocity dispersion and high confinement for broadband SCG the Si3N4 waveguide layer used is typically thick (>~700 nm), which can lead to high stress and cracks unless specialized processing steps are used. Here, we report on efficient octave spanning SCG in a thinner moderate-confinement 400-nm Si3N4 platform using a highly nonlinear tellurium oxide (TeO2) coating. An octave-spanning supercontinuum is achieved at a low peak power of 258 W using a 100-fs laser centered at 1565 nm. Our numerical simulations agree well with the experimental results showing an increase of waveguide's nonlinear parameter by a factor of 2.5 when coating the Si3N4 waveguide with TeO2 film. This work demonstrates highly efficient SCG via effective dispersion engineering and an enhanced nonlinearity in a CMOS-compatible hybrid TeO2-Si3N4 waveguides and a promising route to monolithically integrated nonlinear, linear, and active functionalities on a single silicon photonic chip.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
-
One-step Iterative Estimation of Effective Atomic Number and Electron Density for Dual Energy CT
Authors:
Qian Wang,
Huiqiao Xie,
Tonghe Wang,
Justin Roper,
Hao Gao,
Zhen Tian,
Xiangyang Tang,
Jeffrey D. Bradley,
Tian liu,
Xiaofeng Yang
Abstract:
Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment planning, besides material-selective images, maps of effective atomic number (Z) and relative electron density to that of water ($ρ_e$) can also be achieved and f…
▽ More
Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment planning, besides material-selective images, maps of effective atomic number (Z) and relative electron density to that of water ($ρ_e$) can also be achieved and further employed to improve stop** power ratio accuracy and reduce range uncertainty. In this work, we propose a one-step iterative estimation method, which employs multi-domain gradient $L_0$-norm minimization, for Z and $ρ_e$ maps reconstruction. The algorithm was implemented on GPU to accelerate the predictive procedure and to support potential real-time adaptive treatment planning. The performance of the proposed method is demonstrated via both phantom and patient studies.
△ Less
Submitted 2 August, 2023;
originally announced August 2023.
-
Stimulated Brillouin scattering in tellurite-covered silicon nitride waveguides
Authors:
Roel A. Botter,
Yvan Klaver,
Randy te Morsche,
Bruno L. Segat Frare,
Batoul Hashemi,
Kaixuan Ye,
Akhileshwar Mishra,
Redlef B. G. Braamhaar,
Jonathan D. B. Bradley,
David Marpaung
Abstract:
Stimulated Brillouin scattering (SBS), a coherent nonlinear effect coupling acoustics and optics, can be used in a wide range of applications such as Brillouin lasers and tunable narrowband RF filtering. Wide adoption of such technologies however, would need a balance of strong Brillouin interaction and low optical loss in a structure compatible with large scale fabrication. Achieving these charac…
▽ More
Stimulated Brillouin scattering (SBS), a coherent nonlinear effect coupling acoustics and optics, can be used in a wide range of applications such as Brillouin lasers and tunable narrowband RF filtering. Wide adoption of such technologies however, would need a balance of strong Brillouin interaction and low optical loss in a structure compatible with large scale fabrication. Achieving these characteristics in scalable platforms such as silicon and silicon nitride remains a challenge. Here, we investigate a scalable Brillouin platform combining low loss Si$_3$N$_4$ and tellurium oxide (TeO$_2$) exhibiting strong Brillouin response and enhanced acoustic confinement. In this platform we measure a Brillouin gain coefficient of 8.5~m$^{-1}$W$^{-1}$, exhibiting a twenty fold improvement over the largest previously reported Brillouin gain in a Si$_3$N$_4$ platform. Further, we demonstrate cladding engineering to control the strength of the Brillouin interaction. We utilized the Brillouin gain and loss resonances in this waveguide for an RF photonic filter with more than 15 dB rejection and 250 MHz linewidth. Finally, we present a pathway by geometric optimization and cladding engineering to a further enhancement of the gain coefficient to 155~m$^{-1}$W$^{-1}$, a potential 400 times increase in the Brillouin gain coefficient.
△ Less
Submitted 24 July, 2023;
originally announced July 2023.
-
Chip-scale, CMOS-compatible, high energy passively Q-switched laser
Authors:
Neetesh Singh,
Jan Lorenzen,
Milan Sinobad,
Kai Wang,
Andreas C. Liapis,
Henry Frankis,
Stefanie Haugg,
Henry Francis,
Jose Carreira,
Michael Geiselmann,
Mahmoud A. Gaafar,
Tobias Herr,
Jonathan D. B. Bradley,
Zhipei Sun,
Sonia M Garcia-Blanco,
Franz X. Kartner
Abstract:
Chip-scale, high-energy optical pulse generation is becoming increasingly important as we expand activities into hard to reach areas such as space and deep ocean. Q-switching of the laser cavity is the best known technique for generating high-energy pulses, and typically such systems are in the realm of large bench-top solid-state lasers and fiber lasers, especially in the long wavelength range >1…
▽ More
Chip-scale, high-energy optical pulse generation is becoming increasingly important as we expand activities into hard to reach areas such as space and deep ocean. Q-switching of the laser cavity is the best known technique for generating high-energy pulses, and typically such systems are in the realm of large bench-top solid-state lasers and fiber lasers, especially in the long wavelength range >1.8 um, thanks to their large energy storage capacity. However, in integrated photonics, the very property of tight mode confinement, that enables a small form factor, becomes an impediment to high energy application due to small optical mode cross-section. In this work, we demonstrate complementary metal-oxide-semiconductor (CMOS) compatible, rare-earth gain based large mode area (LMA) passively Q-switched laser in a compact footprint. We demonstrate high on-chip output pulse energy of >150 nJ in single transverse fundamental mode in the eye-safe window (1.9 um), with a slope efficiency ~ 40% in a footprint of ~9 mm2. The high energy pulse generation demonstrated in this work is comparable or in many cases exceeds Q-switched fiber lasers. This bodes well for field applications in medicine and space.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
MRI-based Material Mass Density and Relative Stop** Power Estimation via Deep Learning for Proton Therapy
Authors:
Yuan Gao,
Chih-Wei Chang,
Sagar Mandava,
Raanan Marants,
Jessica E. Scholey,
Matthew Goette,
Yang Lei,
Hui Mao,
Jeffrey D. Bradley,
Tian Liu,
Jun Zhou,
Atchar Sudhyadhom,
Xiaofeng Yang
Abstract:
Magnetic Resonance Imaging (MRI) is increasingly incorporated into treatment planning, because of its superior soft tissue contrast used for tumor and soft tissue delineation versus computed tomography (CT). However, MRI cannot directly provide mass density or relative stop** power (RSP) maps required for proton radiotherapy dose calculation. To demonstrate the feasibility of MRI-only based mass…
▽ More
Magnetic Resonance Imaging (MRI) is increasingly incorporated into treatment planning, because of its superior soft tissue contrast used for tumor and soft tissue delineation versus computed tomography (CT). However, MRI cannot directly provide mass density or relative stop** power (RSP) maps required for proton radiotherapy dose calculation. To demonstrate the feasibility of MRI-only based mass density and RSP estimation using deep learning (DL) for proton radiotherapy. A DL-based framework was developed to discover underlying voxel-wise correlation between MR images and mass density and RSP. Five tissue substitute phantoms including skin, muscle, adipose, 45% hydroxyapatite (HA), and spongiosa bone were customized for MRI scanning based on material composition information from ICRP reports. Two animal tissue phantoms made of pig brain and liver were prepared for DL training. In the phantom study, two DL models were trained: one containing clinical T1 and T2 MRIs and another incorporating zero echo time (ZTE) MRIs as input. In the patient application study, two DL models were trained: one including T1 and T2 MRIs as input, and one incorporating synthetic dual-energy computed tomography (sDECT) images to provide bone tissue information. In the phantom study, DL model based on T1 and T2 MRI demonstrated higher accuracy mass density and RSP estimation in skin, muscle, adipose, brain, and liver with mean absolute percentage errors (MAPE) of 0.42%, 0.14%, 0.19%, 0.78% and 0.26% for mass density and 0.30%, 0.11%, 0.16%, 0.61% and 0.23% for RSP, respectively. DL model incorporating ZTE MRI improved the accuracy of mass density and RSP estimation in 45% HA and spongiosa bone with MAPE at 0.23% and 0.09% for mass density and 0.19% and 0.07% for RSP, respectively. Results show feasibility of MRI-only based mass density and RSP estimation for proton therapy treatment planning using DL method.
△ Less
Submitted 11 October, 2022;
originally announced October 2022.
-
Subwavelength grating metamaterial waveguides and ring resonators on a silicon nitride platform
Authors:
Cameron M. Naraine,
Jocelyn N. Westwood-Bachman,
Cameron Horvath,
Mirwais Aktary,
Andrew P. Knights,
Jens H. Schmid,
Pavel Cheben,
Jonathan D. B. Bradley
Abstract:
We propose and demonstrate subwavelength grating (SWG) metamaterial waveguides and ring resonators on a silicon nitride platform for the first time. The SWG waveguide is engineered such that a large overlap of 53% of the Bloch mode with the top cladding material is achieved, demonstrating excellent potential for applications in evanescent field sensing and light amplification. The devices, which h…
▽ More
We propose and demonstrate subwavelength grating (SWG) metamaterial waveguides and ring resonators on a silicon nitride platform for the first time. The SWG waveguide is engineered such that a large overlap of 53% of the Bloch mode with the top cladding material is achieved, demonstrating excellent potential for applications in evanescent field sensing and light amplification. The devices, which have critical dimensions greater than 100 nm, are fabricated using a commercial rapid turn-around silicon nitride prototy** foundry process using electron beam lithography. Experimental characterization of the fabricated device reveals excellent ring resonator internal quality factor (2.11x10^5) and low propagation loss (~1.5 dB/cm) in the C-band, a significant improvement of both parameters compared to silicon based SWG ring resonators. These results demonstrate the promising prospects of SWG metamaterial structures for silicon nitride based photonic integrated circuits.
△ Less
Submitted 19 September, 2022;
originally announced September 2022.
-
Deformable Image Registration using Unsupervised Deep Learning for CBCT-guided Abdominal Radiotherapy
Authors:
Huiqiao Xie,
Yang Lei,
Yabo Fu,
Tonghe Wang,
Justin Roper,
Jeffrey D. Bradley,
Pretesh Patel,
Tian Liu,
Xiaofeng Yang
Abstract:
CBCTs in image-guided radiotherapy provide crucial anatomy information for patient setup and plan evaluation. Longitudinal CBCT image registration could quantify the inter-fractional anatomic changes. The purpose of this study is to propose an unsupervised deep learning based CBCT-CBCT deformable image registration. The proposed deformable registration workflow consists of training and inference s…
▽ More
CBCTs in image-guided radiotherapy provide crucial anatomy information for patient setup and plan evaluation. Longitudinal CBCT image registration could quantify the inter-fractional anatomic changes. The purpose of this study is to propose an unsupervised deep learning based CBCT-CBCT deformable image registration. The proposed deformable registration workflow consists of training and inference stages that share the same feed-forward path through a spatial transformation-based network (STN). The STN consists of a global generative adversarial network (GlobalGAN) and a local GAN (LocalGAN) to predict the coarse- and fine-scale motions, respectively. The network was trained by minimizing the image similarity loss and the deformable vector field (DVF) regularization loss without the supervision of ground truth DVFs. During the inference stage, patches of local DVF were predicted by the trained LocalGAN and fused to form a whole-image DVF. The local whole-image DVF was subsequently combined with the GlobalGAN generated DVF to obtain final DVF. The proposed method was evaluated using 100 fractional CBCTs from 20 abdominal cancer patients in the experiments and 105 fractional CBCTs from a cohort of 21 different abdominal cancer patients in a holdout test. Qualitatively, the registration results show great alignment between the deformed CBCT images and the target CBCT image. Quantitatively, the average target registration error (TRE) calculated on the fiducial markers and manually identified landmarks was 1.91+-1.11 mm. The average mean absolute error (MAE), normalized cross correlation (NCC) between the deformed CBCT and target CBCT were 33.42+-7.48 HU, 0.94+-0.04, respectively. This promising registration method could provide fast and accurate longitudinal CBCT alignment to facilitate inter-fractional anatomic changes analysis and prediction.
△ Less
Submitted 29 August, 2022;
originally announced August 2022.
-
Multimodal Imaging-based Material Mass Density Estimation for Proton Therapy Using Physics-Constrained Deep Learning
Authors:
Chih-Wei Chang,
Raanan Marants,
Yuan Gao,
Matthew Goette,
Jessica E. Scholey,
Jeffrey D. Bradley,
Tian Liu,
Jun Zhou,
Atchar Sudhyadhom,
Xiaofeng Yang
Abstract:
Map** computed tomography (CT) number to material property dominates the proton range uncertainty. This work aims to develop a physics-constrained deep learning-based multimodal imaging (PDMI) framework to integrate physics, deep learning, magnetic resonance imaging (MRI), and advanced dual-energy CT (DECT) to derive accurate patient mass density maps. Seven tissue substitute MRI phantoms were u…
▽ More
Map** computed tomography (CT) number to material property dominates the proton range uncertainty. This work aims to develop a physics-constrained deep learning-based multimodal imaging (PDMI) framework to integrate physics, deep learning, magnetic resonance imaging (MRI), and advanced dual-energy CT (DECT) to derive accurate patient mass density maps. Seven tissue substitute MRI phantoms were used for PDMI-based material calibration. The training inputs are from MRI and twin-beam dual-energy images acquired at 120 kVp with gold and tin filters. The feasibility investigation included an empirical DECT correlation and four residual networks (ResNet) derived from different training inputs and strategies by the PDMI framework. PRN-MR-DE and RN-MR-DE denote ResNet trained with and without a physics constraint using MRI and DECT images. PRN-DE and RN-DE represent ResNet trained with and without a physics constraint using DECT-only images. For the tissue surrogate study, PRN-MR-DE, PRN-DE, and RN-MR-DE result in mean mass density errors: -0.72%, 2.62%, -3.58% for adipose; -0.03%, -0.61%, and -0.18% for muscle; -0.58%, -1.36%, and -4.86% for 45% HA bone. The retrospective patient study indicated that PRN-MR-DE predicted the densities of soft tissue and bone within expected intervals based on the literature survey, while PRN-DE generated large density deviations. The proposed PDMI framework can generate accurate mass density maps using MRI and DECT images. The physics-constrained training can further enhance model efficacy, making PRN-MR-DE outperform RN-MR-DE. The patient investigation also shows that the PDMI framework has the potential to improve proton range uncertainty with accurate patient mass density maps.
△ Less
Submitted 28 July, 2022; v1 submitted 26 July, 2022;
originally announced July 2022.
-
A thulium-silicon hybrid microdisk laser
Authors:
Khadijeh Miarabbas Kiani,
Henry C. Frankis,
Cameron M. Naraine,
Dawson B. Bonneville,
Andrew P. Knights,
Jonathan D. B. Bradley
Abstract:
Silicon photonics technology enables compact, low-power and cost-effective optical microsystems on a chip by leveraging the materials and advanced fabrication methods developed over decades for integrated silicon electronics. Silicon foundries now provide many standard building blocks required for high-performance optical circuits, including passive components such as optical waveguides, filters a…
▽ More
Silicon photonics technology enables compact, low-power and cost-effective optical microsystems on a chip by leveraging the materials and advanced fabrication methods developed over decades for integrated silicon electronics. Silicon foundries now provide many standard building blocks required for high-performance optical circuits, including passive components such as optical waveguides, filters and (de-)multiplexors and active optoelectronic components such as high-speed modulators, switches and photodetectors. However, because silicon is a poor light emitting material, on-chip light sources are still a significant challenge for foundry offerings. Current light-source integration methods are viewed as complex, requiring incompatible and/or expensive materials and processing steps. Here we report on an ultra-compact silicon photonic laser consisting of a thulium-silicon hybrid microdisk resonator. The microdisk design is straightforward and compatible with the fabrication steps and device dimensions available in all silicon photonics foundries, whereas the gain medium is added in a backend (final step), room temperature sputter deposition. This approach allows for low-cost and high-volume wafer-scale manufacturing and co-integration of light sources with silicon passive and active devices with no adjustment to standard process flows. The hybrid laser is pumped at standard telecom wavelengths around 1.6 μm and emits around 1.9 μm, which is within an emerging spectral region of significant interest for communications, nonlinear and quantum optics, and sensing on silicon.
△ Less
Submitted 21 April, 2021;
originally announced April 2021.
-
Knowledge-based Radiation Treatment Planning: A Data-driven Method Survey
Authors:
Shadab Momin,
Yabo Fu,
Yang Lei,
Justin Roper,
Jeffrey D. Bradley,
Walter J. Curran,
Tian Liu,
Xiaofeng Yang
Abstract:
This paper surveys the data-driven dose prediction approaches introduced for knowledge-based planning (KBP) in the last decade. These methods were classified into two major categories according to their methods and techniques of utilizing previous knowledge: traditional KBP methods and deep-learning-based methods. Previous studies that required geometric or anatomical features to either find the b…
▽ More
This paper surveys the data-driven dose prediction approaches introduced for knowledge-based planning (KBP) in the last decade. These methods were classified into two major categories according to their methods and techniques of utilizing previous knowledge: traditional KBP methods and deep-learning-based methods. Previous studies that required geometric or anatomical features to either find the best matched case(s) from repository of previously delivered treatment plans or build prediction models were included in traditional methods category, whereas deep-learning-based methods included studies that trained neural networks to make dose prediction. A comprehensive review of each category is presented, highlighting key parameters, methods, and their outlooks in terms of dose prediction over the years. We separated the cited works according to the framework and cancer site in each category. Finally, we briefly discuss the performance of both traditional KBP methods and deep-learning-based methods, and future trends of both data-driven KBP approaches.
△ Less
Submitted 18 September, 2020; v1 submitted 15 September, 2020;
originally announced September 2020.
-
Deep learning-based Real-time Volumetric Imaging for Lung Stereotactic Body Radiation Therapy: A Proof of Concept Study
Authors:
Yang Lei,
Zhen Tian,
Tonghe Wang,
Kristin Higgins,
Jeffrey D. Bradley,
Walter J. Curran,
Tian Liu,
Xiaofeng Yang
Abstract:
Due to the inter- and intra- variation of respiratory motion, it is highly desired to provide real-time volumetric images during the treatment delivery of lung stereotactic body radiation therapy (SBRT) for accurate and active motion management. In this proof-of-concept study, we propose a novel generative adversarial network integrated with perceptual supervision to derive instantaneous volumetri…
▽ More
Due to the inter- and intra- variation of respiratory motion, it is highly desired to provide real-time volumetric images during the treatment delivery of lung stereotactic body radiation therapy (SBRT) for accurate and active motion management. In this proof-of-concept study, we propose a novel generative adversarial network integrated with perceptual supervision to derive instantaneous volumetric images from a single 2D projection. Our proposed network, named TransNet, consists of three modules, i.e., encoding, transformation and decoding modules. Rather than only using image distance loss between the generated 3D images and the ground truth 3D CT images to supervise the network, perceptual loss in feature space is integrated into loss function to force the TransNet to yield accurate lung boundary. Adversarial supervision is also used to improve the realism of generated 3D images. We conducted a simulation study on 20 patient cases, who had received lung SBRT treatments in our institution and undergone 4D-CT simulation, and evaluated the efficacy and consistency of our method for four different projection angles, i.e., 0, 30, 60 and 90 degree. For each 3D CT image set of a breathing phase, we simulated its 2D projections at these angles.Then for each projection angle, a patient's 3D CT images of 9 phases and the corresponding 2D projection data were used for training, with the remaining phase used for testing. The mean absolute error, normalized MAE, peak signal-to-noise ratio and structural similarity index metric achieved by our method are 99.3 HU, 0.032, 23.4 dB and 0.949, respectively. These results demonstrate the feasibility and efficacy of our 2D-to-3D method for lung cancer patients, which provides a potential solution for in-treatment real-time on-board volumetric imaging for accurate dose delivery to ensure the effectiveness of lung SBRT treatment.
△ Less
Submitted 24 May, 2020;
originally announced May 2020.
-
Integrated TiO2 resonators for visible photonics
Authors:
Jennifer T. Choy,
Jonathan D. B. Bradley,
Parag B. Deotare,
Ian B. Burgess,
Christopher C. Evans,
Eric Mazur,
Marko Loncar
Abstract:
We demonstrate waveguide-coupled titanium dioxide (TiO2) racetrack resonators with loaded quality factors of 2x10^4 for the visible wavelengths. The structures were fabricated in sputtered TiO2 thin films on oxidized silicon substrates using standard top-down nanofabrication techniques, and passively probed in transmission measurements using a tunable red laser. Devices based on this material coul…
▽ More
We demonstrate waveguide-coupled titanium dioxide (TiO2) racetrack resonators with loaded quality factors of 2x10^4 for the visible wavelengths. The structures were fabricated in sputtered TiO2 thin films on oxidized silicon substrates using standard top-down nanofabrication techniques, and passively probed in transmission measurements using a tunable red laser. Devices based on this material could serve as integrated optical elements as well as passive platforms for coupling to visible quantum emitters.
△ Less
Submitted 15 November, 2011;
originally announced November 2011.