-
Methodology for measuring photonuclear reaction cross sections with an electron accelerator based on Bayesian analysis
Authors:
Saverio Braccini,
Pierluigi Casolaro,
Gaia Dellepiane,
Christian Kottler,
Matthias Lüthi,
Lorenzo Mercolli,
Peter Peier,
Paola Scampoli,
Andreas Türler
Abstract:
Accurate measurements of photonuclear reaction cross sections are crucial for a number of applications, including radiation shielding design, absorbed dose calculations, reactor physics and engineering, nuclear safeguard and inspection, astrophysics, and nuclear medicine. Primarily motivated by the study of the production of selected radionuclides with high-energy photon beams (mainly 225Ac, 47Sc,…
▽ More
Accurate measurements of photonuclear reaction cross sections are crucial for a number of applications, including radiation shielding design, absorbed dose calculations, reactor physics and engineering, nuclear safeguard and inspection, astrophysics, and nuclear medicine. Primarily motivated by the study of the production of selected radionuclides with high-energy photon beams (mainly 225Ac, 47Sc, and 67Cu), we have established a methodology for the measurement of photonuclear reaction cross sections with the microtron accelerator available at the Swiss Federal Institute of Metrology (METAS). The proposed methodology is based on the measurement of the produced activity with a High Purity Germanium (HPGe) spectrometer and on the knowledge of the photon fluence spectrum through Monte Carlo simulations. The data analysis is performed by applying a Bayesian fitting procedure to the experimental data and by assuming a functional trend of the cross section, in our case a Breit-Wigner function. We validated the entire methodology by measuring a well-established photonuclear cross section, namely the 197Au(γ,n)196Au reaction. The results are consistent with those reported in the literature.
△ Less
Submitted 20 September, 2023;
originally announced September 2023.
-
A facility for radiation hardness studies based on a medical cyclotron
Authors:
John Anders,
Saverio Braccini,
Tommaso Stefano Carzaniga,
Pierluigi Casolaro,
Meghranjana Chatterjee,
Gaia Dellepiane,
Laura Franconi,
Lea Halser,
Armin Ilg,
Isidre Mateu,
Federico Meloni,
Claudia Merlassino,
Antonio Miucci,
Roman Müller,
Marco Rimoldi,
Michele Weber
Abstract:
The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate…
▽ More
The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate. In this article, we present a versatile installation based on a medical cyclotron located at the Bern University Hospital (Inselspital), which is used as a controlled 18-MeV proton source. This accelerator is used for daily production of medical radioisotopes, as well as for multidisciplinary research, thanks to a 6.5-meter long beam transfer line that terminates in an independent bunker, dedicated only to scientific activities. The facility offers a wide range of proton fluxes, due to an adjustable beam current from approximately 10 pA to the micro-ampere range, together with a series of steering and focusing magnets along the beamline that allow for the beam spot to be focused down to a few mm^2. The beamline can be instrumented with a variety of beam monitoring detectors, collimators, and beam current measurement devices to precisely control the irradiation conditions. The facility also hosts a well equipped laboratory dedicated to the characterisation of samples after irradiation. An experimental validation of the irradiation setup, with proton fluxes ranging from $5\times10^9$ cm$^{-2}$s$^{-1}$ to $4\times10^{11}$ cm$^{-2}$s$^{-1}$, is reported in this article.
△ Less
Submitted 22 March, 2022; v1 submitted 11 January, 2022;
originally announced January 2022.
-
Radiation-induced effects in glass windows for optical readout GEM-based detectors
Authors:
A. Maia Oliveira,
S. Braccini,
P. Casolaro,
N. Heracleous,
J. Leidner,
I. Mateu,
F. Murtas,
M. Silari
Abstract:
In this paper we present irradiation measurements performed to select a transparent anode substrate that best meets the requirements of an optical readout for a novel detector, the LaGEMPix. The modification of the optical properties of the material due to proton irradiation were studied in soda-lime, fused quartz and fused silica glasses coated with an Indium Tin Oxide layer. The irradiations wer…
▽ More
In this paper we present irradiation measurements performed to select a transparent anode substrate that best meets the requirements of an optical readout for a novel detector, the LaGEMPix. The modification of the optical properties of the material due to proton irradiation were studied in soda-lime, fused quartz and fused silica glasses coated with an Indium Tin Oxide layer. The irradiations were performed using the research Beam Transfer Line (BTL) of the IBA Cyclone 18 MeV cyclotron of the Bern University Hospital (Inselspital). We recorded visible scintillation light generated by proton irradiation in the soda-lime and fused quartz samples. We also investigated the darkening of these three glasses and observed radiation-induced colour centres in the soda-lime glass sample. The optical transmission spectra of the samples were measured before and after irradiation. Reductions of 45%, 1% and 0.4% were observed for soda-lime glass, fused quartz and fused silica, respectively (with an associated error of 0.25%). We conclude that the best option for our specific application is the fused silica substrate, which will be the transparent anode for the next generation of the LaGEMPix detector.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Charge collection characterisation with the Transient Current Technique of the ams H35DEMO CMOS detector after proton irradiation
Authors:
John Anders,
Mathieu Benoit,
Saverio Braccini,
Raimon Casanova,
Hucheng Chen,
Kai Chen,
Francesco Armando di Bello,
Armin Fehr,
Didier Ferrere,
Dean Forshaw,
Tobias Golling,
Sergio Gonzalez-Sevilla,
Giuseppe Iacobucci,
Moritz Kiehn,
Francesco Lanni,
Hongbin Liu,
Lingxin Meng,
Claudia Merlassino,
Antonio Miucci,
Marzio Nessi,
Ivan Perić,
Marco Rimoldi,
D M S Sultan,
Mateus Vincente Barreto Pinto,
Eva Vilella
, et al. (4 additional authors not shown)
Abstract:
This paper reports on the characterisation with Transient Current Technique measurements of the charge collection and depletion depth of a radiation-hard high-voltage CMOS pixel sensor produced at ams AG. Several substrate resistivities were tested before and after proton irradiation with two different sources: the 24 GeV Proton Synchrotron at CERN and the 16.7 MeV Cyclotron at Bern Inselspital.
This paper reports on the characterisation with Transient Current Technique measurements of the charge collection and depletion depth of a radiation-hard high-voltage CMOS pixel sensor produced at ams AG. Several substrate resistivities were tested before and after proton irradiation with two different sources: the 24 GeV Proton Synchrotron at CERN and the 16.7 MeV Cyclotron at Bern Inselspital.
△ Less
Submitted 25 July, 2018;
originally announced July 2018.
-
A facility for radiation hardness studies based on the Bern medical cyclotron
Authors:
John Anders,
Saverio Braccini,
Tommaso Carzaniga,
Antonio Ereditato,
Armin Fehr,
Federico Meloni,
Claudia Merlassino,
Antonio Miucci,
Marco Rimoldi,
Michele Weber
Abstract:
The development of instrumentation to be operated in high-radiation environments is one of the main challenges in fundamental research. Besides space and nuclear applications, particle physics experiments also need radiation-hard devices. The focus of this paper is a new irradiation facility based on the medical cyclotron located at the Bern University Hospital (Insespital), which is used as a con…
▽ More
The development of instrumentation to be operated in high-radiation environments is one of the main challenges in fundamental research. Besides space and nuclear applications, particle physics experiments also need radiation-hard devices. The focus of this paper is a new irradiation facility based on the medical cyclotron located at the Bern University Hospital (Insespital), which is used as a controlled 18 MeV proton source. The adjustable beam current allows for dose rate dependent characterisation over a large dynamic range, from 0.1 to 1000 Grad per hour. The beam can be tuned so that the user can obtain the desired irradiation conditions. A complete study of the device under irradiation is possible thanks to dedicated beam monitoring systems as well as a power control system for the device under irradiation, which can be operated on-line. Further characterisations of the irradiated devices are possible thanks to a laboratory equipped with gamma spectroscopy detectors, ammeters and transient current technique setups.
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Test beam measurement of ams H35 HV-CMOS capacitively coupled pixel sensor prototypes with high-resistivity substrate
Authors:
M. Benoit,
S. Braccini,
R. Casanova,
E. Cavallaro,
H. Chen,
K. Chen,
F. A. Di Bello,
D. Ferrere,
D. Frizzell,
T. Golling,
S. Gonzalez-Sevilla,
S. Grinstein,
G. Iacobucci,
M. Kiehn,
F. Lanni,
H. Liu,
J. Metcalfe,
L. Meng,
C. Merlassino,
A. Miucci,
D. Muenstermann,
M. Nessi,
H. Okawa,
I. Perić,
M. Rimoldi
, et al. (12 additional authors not shown)
Abstract:
In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO demonstrator, containing different diode and amplifier designs, was produced in ams H35 HV-CMOS technology using four different substrate resistivities spanning fr…
▽ More
In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO demonstrator, containing different diode and amplifier designs, was produced in ams H35 HV-CMOS technology using four different substrate resistivities spanning from $\mathrm{80}$ to $\mathrm{1000~Ω\cdot cm}$. A glueing process using a high-precision flip-chip machine was developed in order to capacitively couple the sensors to FE-I4 Readout ASIC using a thin layer of epoxy glue with good uniformity over a large surface. The resulting assemblies were measured in beam test at the Fermilab Test Beam Facilities with 120 GeV protons and CERN SPS H8 beamline using 80 GeV pions. The in-time efficiency and tracking properties measured for the different sensor types are shown to be compatible with the ATLAS ITk requirements for its pixel sensors.
△ Less
Submitted 3 December, 2018; v1 submitted 22 December, 2017;
originally announced December 2017.
-
A system for online beam emittance measurements and proton beam characterization
Authors:
K. P. Nesteruk,
M. Auger,
S. Braccini,
T. S. Carzaniga,
A. Ereditato,
P. Scampoli
Abstract:
A system for online measurement of the transverse beam emittance was developed. It is named $^{4}$PrOB$\varepsilon$aM (4-Profiler Online Beam Emittance Measurement) and was conceived to measure the emittance in a fast and efficient way using the multiple beam profiler method. The core of the system is constituted by four consecutive UniBEaM profilers, which are based on silica fibers passing acros…
▽ More
A system for online measurement of the transverse beam emittance was developed. It is named $^{4}$PrOB$\varepsilon$aM (4-Profiler Online Beam Emittance Measurement) and was conceived to measure the emittance in a fast and efficient way using the multiple beam profiler method. The core of the system is constituted by four consecutive UniBEaM profilers, which are based on silica fibers passing across the beam. The $^{4}$PrOB$\varepsilon$aM system was deployed for characterization studies of the 18~MeV proton beam produced by the IBA Cyclone 18 MeV cyclotron at Bern University Hospital (Inselspital). The machine serves daily radioisotope production and multi-disciplinary research, which is carried out with a specifically conceived Beam Transport Line (BTL). The transverse RMS beam emittance of the cyclotron was measured as a function of several machine parameters, such as the magnetic field, RF peak voltage, and azimuthal angle of the stripper. The beam emittance was also measured using the method based on the quadrupole strength variation. The results obtained with both techniques were compared and a good agreement was found. In order to characterize the longitudinal dynamics, the proton energy distribution was measured. For this purpose, a method was developed based on aluminum absorbers of different thicknesses, a UniBEaM detector, and a Faraday cup. The results were an input for a simulation of the BTL developed in the MAD-X software. This tool allows machine parameters to be tuned online and the beam characteristics to be optimized for specific applications.
△ Less
Submitted 21 March, 2018; v1 submitted 21 May, 2017;
originally announced May 2017.
-
High efficiency cyclotron trap assisted positron moderator
Authors:
L. Gerchow,
D. A. Cooke,
S. Braccini,
M. Döbeli,
K. Kirch,
U. Köster,
A. Müller,
N. P. Van Der Meulen,
C. Vermeulen,
A. Rubbia,
P. Crivelli
Abstract:
We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $β^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the…
▽ More
We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $β^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the art of tungsten moderators. The simulation validated with this measurement suggests that using an optimised setup even higher efficiencies are achievable.
△ Less
Submitted 17 March, 2017;
originally announced March 2017.
-
Testbeam results of irradiated ams H18 HV-CMOS pixel sensor prototypes
Authors:
M. Benoit,
S. Braccini,
G. Casse,
H. Chen,
K. Chen,
F. A. Di Bello,
D. Ferrere,
T. Golling,
S. Gonzalez-Sevilla,
G. Iacobucci,
M. Kiehn,
F. Lanni,
H. Liu,
L. Meng,
C. Merlassino,
A. Miucci,
D. Muenstermann,
M. Nessi,
H. Okawa,
I. Peric,
M. Rimoldi,
B. Ristic,
M. Vicente Barrero Pinto,
J. Vossebeld,
M. Weber
, et al. (4 additional authors not shown)
Abstract:
HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the $4^{\mathrm{th}}$ generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the am…
▽ More
HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the $4^{\mathrm{th}}$ generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between $1\cdot 10^{14}$ and $5\cdot 10^{15}$ 1-MeV-n$_\textrm{eq}$/cm$^2$. The sensors were glued to ATLAS FE-I4 pixel readout chips and measured at the CERN SPS H8 beamline using the FE-I4 beam telescope. Results for all fluences are very encouraging with all hit efficiencies being better than 97% for bias voltages of $85\,$V. The sample irradiated to a fluence of $1\cdot 10^{15}$ n$_\textrm{eq}$/cm$^2$ - a relevant value for a large volume of the upgraded tracker - exhibited 99.7% average hit efficiency. The results give strong evidence for the radiation tolerance of HV-CMOS sensors and their suitability as sensors for the experimental HL-LHC upgrades and future large-area silicon-based tracking detectors in high-radiation environments.
△ Less
Submitted 28 November, 2017; v1 submitted 8 November, 2016;
originally announced November 2016.
-
Particle Accelerators and Detectors for medical Diagnostics and Therapy
Authors:
Saverio Braccini
Abstract:
This Habilitationsschrift (Habilitation thesis) is focused on my research activities on medical applications of particle physics and was written in 2013 to obtain the Venia Docendi (Habilitation) in experimental physics at the University of Bern. It is based on selected publications, which represented at that time my major scientific contributions as an experimental physicist to the field of parti…
▽ More
This Habilitationsschrift (Habilitation thesis) is focused on my research activities on medical applications of particle physics and was written in 2013 to obtain the Venia Docendi (Habilitation) in experimental physics at the University of Bern. It is based on selected publications, which represented at that time my major scientific contributions as an experimental physicist to the field of particle accelerators and detectors applied to medical diagnostics and therapy. The thesis is structured in two parts. In Part I, Chapter 1 presents an introduction to accelerators and detectors applied to medicine, with particular focus on cancer hadrontherapy and on the production of radioactive isotopes. In Chapter 2, my publications on medical particle accelerators are introduced and put into their perspective. In particular, high frequency linear accelerators for hadrontherapy are discussed together with the new Bern cyclotron laboratory. Chapter 3 is dedicated to particle detectors with particular emphasis on three instruments I contributed to propose and develop: segmented ionization chambers for hadrontherapy, a proton radiography apparatus with nuclear emulsion films, and a beam monitor detector for ion beams based on doped silica fibres. Selected research and review papers are contained in Part II. For copyright reasons, they are only listed and not reprinted in this on-line version. They are available on the websites of the journals.
△ Less
Submitted 25 January, 2016;
originally announced January 2016.
-
An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles
Authors:
M. Nirkko,
S. Braccini,
A. Ereditato,
I. Kreslo,
P. Scampoli,
M. Weber
Abstract:
A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the sim…
▽ More
A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.
△ Less
Submitted 5 February, 2013; v1 submitted 13 November, 2012;
originally announced November 2012.
-
A new application of emulsions to measure the gravitational force on antihydrogen
Authors:
C. Amsler,
A. Ariga,
T. Ariga,
S. Braccini,
C. Canali,
A. Ereditato,
J. Kawada,
M. Kimura,
I. Kreslo,
C. Pistillo,
P. Scampoli,
J. W. Storey
Abstract:
We propose to build and operate a detector based on the emulsion film technology for the measurement of the gravitational acceleration on antimatter, to be performed by the AEgIS experiment (AD6) at CERN. The goal of AEgIS is to test the weak equivalence principle with a precision of 1% on the gravitational acceleration g by measuring the vertical position of the anni- hilation vertex of antihydro…
▽ More
We propose to build and operate a detector based on the emulsion film technology for the measurement of the gravitational acceleration on antimatter, to be performed by the AEgIS experiment (AD6) at CERN. The goal of AEgIS is to test the weak equivalence principle with a precision of 1% on the gravitational acceleration g by measuring the vertical position of the anni- hilation vertex of antihydrogen atoms after their free fall in a horizontal vacuum pipe. With the emulsion technology developed at the University of Bern we propose to improve the performance of AEgIS by exploiting the superior position resolution of emulsion films over other particle de- tectors. The idea is to use a new type of emulsion films, especially developed for applications in vacuum, to yield a spatial resolution of the order of one micron in the measurement of the sag of the antihydrogen atoms in the gravitational field. This is an order of magnitude better than what was planned in the original AEgIS proposal.
△ Less
Submitted 27 December, 2012; v1 submitted 6 November, 2012;
originally announced November 2012.
-
A beam monitor detector based on doped silica and optical fibres
Authors:
S. Braccini,
A. Ereditato,
F. Giacoppo,
I. Kreslo,
K. P. Nesteruk,
M. Nirkko,
M. Weber,
P. Scampoli,
M. Neff,
S. Pilz,
V. Romano
Abstract:
A beam monitor detector prototype based on doped silica fibres coupled to optical fibres has been designed, constructed and tested, mainly for accelerators used in medical applications. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam has been measured, giving information on beam position, shape and intensity. Mostly based on commercial components, the detector…
▽ More
A beam monitor detector prototype based on doped silica fibres coupled to optical fibres has been designed, constructed and tested, mainly for accelerators used in medical applications. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam has been measured, giving information on beam position, shape and intensity. Mostly based on commercial components, the detector is easy to install, to operate and no electronic components are located near the beam. Tests have been performed with a 2 MeV proton pulsed beam at an average current of 0.8 μA. The response characteristics of Sb doped silica fibres have been studied for the first time.
△ Less
Submitted 15 February, 2012; v1 submitted 7 October, 2011;
originally announced October 2011.
-
Calibration and sensitivity of the Virgo detector during its second science run
Authors:
The Virgo Collaboration,
T. Accadia,
F. Acernese,
F. Antonucci,
P. Astone,
G. Ballardin,
F. Barone,
M. Barsuglia,
A. Basti,
Th. S. Bauer,
M. G. Beker,
A. Belletoile,
S. Birindelli,
M. Bitossi,
M. A. Bizouard,
M. Blom,
F. Bondu,
L. Bonelli,
R. Bonnand,
V. Boschi,
L. Bosi,
B. Bouhou,
S. Braccini,
C. Bradaschia,
A. Brillet
, et al. (153 additional authors not shown)
Abstract:
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to…
▽ More
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.
△ Less
Submitted 18 January, 2011; v1 submitted 27 September, 2010;
originally announced September 2010.
-
First results on proton radiography with nuclear emulsion detectors
Authors:
S. Braccini,
A. Ereditato,
I. Kreslo,
U. Moser,
C. Pistillo,
S. Studer,
P. Scampoli,
A. Coray,
E. Pedroni
Abstract:
We propose an innovative method for proton radiography based on nuclear emulsion film detectors, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. For this purpose, nuclear emulsion films interleaved with tissue equivalent absorbers can be used to reconstruct proton tracks with very high accuracy. This is perfor…
▽ More
We propose an innovative method for proton radiography based on nuclear emulsion film detectors, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. For this purpose, nuclear emulsion films interleaved with tissue equivalent absorbers can be used to reconstruct proton tracks with very high accuracy. This is performed through a fully automated scanning procedure employing optical microscopy, routinely used in neutrino physics experiments. Proton radiography can be used in proton therapy to obtain direct information on the average tissue density for treatment planning optimization and to perform imaging with very low dose to the patient. The first prototype of a nuclear emulsion based detector has been conceived, constructed and tested with a therapeutic proton beam. The first promising experimental results have been obtained by imaging simple phantoms.
△ Less
Submitted 31 March, 2010;
originally announced March 2010.
-
Scientific and Technological Development of Hadrontherapy
Authors:
Saverio Braccini
Abstract:
Hadrontherapy is a novel technique of cancer radiation therapy which employs beams of charged hadrons, protons and carbon ions in particular. Due to their physical and radiobiological properties, they allow one to obtain a more conformal treatment with respect to photons used in conventional radiation therapy, sparing better the healthy tissues located in proximity of the tumour and allowing a h…
▽ More
Hadrontherapy is a novel technique of cancer radiation therapy which employs beams of charged hadrons, protons and carbon ions in particular. Due to their physical and radiobiological properties, they allow one to obtain a more conformal treatment with respect to photons used in conventional radiation therapy, sparing better the healthy tissues located in proximity of the tumour and allowing a higher control of the disease. Hadrontherapy is the direct application of research in high energy physics, making use of specifically conceived particle accelerators and detectors. Protons can be considered today a very important tool in clinical practice due to the several hospital-based centres in operation and to the continuously increasing number of facilities proposed worldwide. Very promising results have been obtained with carbon ion beams, especially in the treatment of specific radio resistant tumours. To optimize the use of charged hadron beams in cancer therapy, a continuous technological challenge is leading to the conception and to the development of innovative methods and instruments. The present status of hadrontherapy is reviewed together with the future scientific and technological perspectives of this discipline.
△ Less
Submitted 6 January, 2010;
originally announced January 2010.
-
Nuclear Emulsion Film Detectors for Proton Radiography: Design and Test of the First Prototype
Authors:
S. Braccini,
A. Ereditato,
I. Kreslo,
U. Moser,
C. Pistillo,
P. Scampoli,
S. Studer
Abstract:
Proton therapy is nowadays becoming a wide spread clinical practice in cancer therapy and sophisticated treatment planning systems are routinely used to exploit at best the ballistic properties of charged particles. The information on the quality of the beams and the range of the protons is a key issue for the optimization of the treatment. For this purpose, proton radiography can be used in pro…
▽ More
Proton therapy is nowadays becoming a wide spread clinical practice in cancer therapy and sophisticated treatment planning systems are routinely used to exploit at best the ballistic properties of charged particles. The information on the quality of the beams and the range of the protons is a key issue for the optimization of the treatment. For this purpose, proton radiography can be used in proton therapy to obtain direct information on the range of the protons, on the average density of the tissues for treatment planning optimization and to perform imaging with negligible dose to the patient. We propose an innovative method based on nuclear emulsion film detectors for proton radiography, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. Nuclear emulsion films interleaved with tissue equivalent absorbers can be fruitfully used to reconstruct proton tracks with very high precision. The first prototype of a nuclear emulsion based detector has been conceived, constructed and tested with a therapeutic proton beam at PSI. The scanning of the emulsions has been performed at LHEP in Bern, where a fully automated microscopic scanning technology has been developed for the OPERA experiment on neutrino oscillations. After track reconstruction, the first promising experimental results have been obtained by imaging a simple phantom made of PMMA with a step of 1 cm. A second phantom with five 5 x 5 mm^2 section aluminum rods located at different distances and embedded in a PMMA structure has been also imaged. Further investigations are in progress to improve the resolution and to image more sophisticated phantoms.
△ Less
Submitted 6 January, 2010;
originally announced January 2010.
-
Cyclinacs: Fast-Cycling Accelerators for Hadrontherapy
Authors:
U. Amaldi,
S. Braccini,
A. Citterio,
K. Crandall,
M. Crescenti,
M. Dominietto,
A. Giuliacci,
G. Magrin,
C. Mellace,
P. Pearce,
G. Pitta',
E. Rosso,
M. Weiss,
R. Zennaro
Abstract:
We propose an innovative fast-cycling accelerator complex conceived and designed to exploit at best the properties of accelerated ion beams for hadrontherapy. A cyclinac is composed by a cyclotron, which can be used also for other valuable medical and research purposes, followed by a high gradient linear accelerator capable to produce ion beams optimized for the irradiation of solid tumours with…
▽ More
We propose an innovative fast-cycling accelerator complex conceived and designed to exploit at best the properties of accelerated ion beams for hadrontherapy. A cyclinac is composed by a cyclotron, which can be used also for other valuable medical and research purposes, followed by a high gradient linear accelerator capable to produce ion beams optimized for the irradiation of solid tumours with the most modern techniques. The properties of cyclinacs together with design studies for protons and carbon ions are presented and the advantages in facing the challenges of hadrontherapy are discussed.
△ Less
Submitted 20 February, 2009;
originally announced February 2009.