-
Pixelated silicon detector for radiation beam profile measurements
Authors:
Joonas Tikkanen,
Stefanie Kirschenmann,
Nikita Kramarenko,
Erik Brücken,
Pirkitta Koponen,
Panja Luukka,
Teemu Siiskonen,
Raimo Turpeinen,
Jennifer Ott
Abstract:
A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint ionization chamber. The differences in the pixel detector and pinpoint chamber relative profiles were within approximately 0.02, and after calculating correction fac…
▽ More
A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint ionization chamber. The differences in the pixel detector and pinpoint chamber relative profiles were within approximately 0.02, and after calculating correction factors with Monte Carlo simulations for the pixel detector, the differences were decreased to almost less than 0.005. The detector's capability to measure pulse-height was used to record an electron pulse-height spectrum in water in the Co-60 beam, and the results agreed well with simulations.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
Characterisation of Gamma-irradiated MCz-Silicon Detectors with a High-$K$ Negative Oxide as Field Insulator
Authors:
S. Bharthuar,
M. Bezak,
E. Brücken,
A Gädda,
M. Golovleva,
A. Karadzhinova-Ferrer,
A. Karjalainen,
N. Kramarenko,
S. Kirschenmann,
P. Luukka,
J. Ott,
E. Tuominen,
M. Väänänen
Abstract:
The high-luminosity operation of the Tracker in the Compact Muon Solenid (CMS) detector at the Large Hadron Collider (LHC) experiment calls for the development of silicon-based sensors. This involves implementation of AC-coupling to micro-scale pixel sensor areas to provide enhanced isolation of radiation-induced leakage currents. The motivation of this study is the development of AC-pixel sensors…
▽ More
The high-luminosity operation of the Tracker in the Compact Muon Solenid (CMS) detector at the Large Hadron Collider (LHC) experiment calls for the development of silicon-based sensors. This involves implementation of AC-coupling to micro-scale pixel sensor areas to provide enhanced isolation of radiation-induced leakage currents. The motivation of this study is the development of AC-pixel sensors with negative oxides (such as aluminium oxide - Al$_2$O$_3$ and hafnium oxide - HfO$_2$) as field insulators that possess good dielectric strength and provide radiation hardness. Thin films of Al$_2$O$_3$ and HfO$_2$ grown by atomic layer deposition (ALD) method were used as dielectrics for capacitive coupling. A comparison study based on dielectric material used in MOS capacitors indicate HfO$_2$ as a better candidate since it provides higher sensitivity (where, the term sensitivity is defined as the ratio of the change in flat-band voltage to dose) to negative charge accumulation with gamma irradiation.
Further, space charge sign inversion was observed for sensors processed on high resistivity p-type Magnetic Czochralski silicon (MCz-Si) substrates that were irradiated with gamma rays up to a dose of 1 MGy. The inter-pixel resistance values of heavily gamma irradiated AC-coupled pixel sensors suggest that high-$K$ negative oxides as field insulators provide a good electrical isolation between the pixels.
△ Less
Submitted 19 November, 2022; v1 submitted 16 November, 2022;
originally announced November 2022.
-
Quality assessment of Cadmium Telluride as a detector material for multispectral medical imaging
Authors:
S. Kirschenmann,
M. Bezak,
S. Bharthuar,
E. Brücken,
M. Golovleva,
A. Gädda,
M. Kalliokoski,
A. Karadzhinova-Ferrer,
P. Koponen,
N. Kramarenko,
P. Luukka,
J. Ott,
J. Tikkanen,
R. Turpeinen,
A. Winkler
Abstract:
Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their varying concentration of defects necessitate a thorough quality assessment before the complex detector processing procedure. We present our quality assessment of…
▽ More
Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their varying concentration of defects necessitate a thorough quality assessment before the complex detector processing procedure. We present our quality assessment of CdTe as a detector material for multispectral medical imaging, a research which is conducted as part of the Consortium Project Multispectral Photon-counting for Medical Imaging and Beam characterization (MPMIB). The aim of the project is to develop novel CdTe detectors and obtain spectrum-per-pixel information that make the distinction between different radiation types and tissues possible. To evaluate the defect density inside the crystals -- which can deteriorate the detector performance -- we employ infrared microscopy (IRM). Posterior data analysis allows us to visualise the defect distributions as 3D defect maps. Additionally, we investigate front and backside differences of the material with current-voltage (IV) measurements to determine the preferred surface for the pixelisation of the crystal, and perform test measurements with the prototypes to provide feedback for further processing. We present the different parts of our quality assessment chain and will close with first experimental results obtained with one of our prototype PC detectors in a small tomographic setup.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
Employing infrared microscopy (IRM) in combination with a pre-trained neural network to visualise and analyse the defect distribution in Cadmium Telluride crystals
Authors:
S. Kirschenmann,
S. Bharthuar,
E. Brücken,
M. Golovleva,
A. Gädda,
M. Kalliokoski,
P. Luukka,
J. Ott,
A. Winkler
Abstract:
While Cadmium Telluride (CdTe) excels in terms of photon radiation absorption properties and outperforms silicon (Si) in this respect, the crystal growth, characterization and processing into a radiation detector is much more complicated. Additionally, large concentrations of extended crystallographic defects, such as grain boundaries, twins, and tellurium (Te) inclusions, vary from crystal to cry…
▽ More
While Cadmium Telluride (CdTe) excels in terms of photon radiation absorption properties and outperforms silicon (Si) in this respect, the crystal growth, characterization and processing into a radiation detector is much more complicated. Additionally, large concentrations of extended crystallographic defects, such as grain boundaries, twins, and tellurium (Te) inclusions, vary from crystal to crystal and can reduce the spectroscopic performance of the processed detector. A quality assessment of the material prior to the complex fabrication process is therefore crucial. To locate the Te-defects, we scan the crystals with infrared microscopy (IRM) in different layers, obtaining a 3D view of the defect distribution. This provides us with important information on the defect density and locations of Te inclusions, and thus a handle to assess the quality of the material. For the classification of defects in the large amount of IRM image data, a convolutional neural network is employed. From the post-processed and analysed IRM data, 3D defect maps of the CdTe crystals are created, which make different patterns of defect agglomerations inside the crystals visible. In total, more than 100 crystals were scanned with the current IRM setup. In this paper, we compare two crystal batches, each consisting of 12 samples. We find significant differences in the defect distributions of the crystals.
△ Less
Submitted 18 August, 2021;
originally announced August 2021.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Hole Misalignment and Gain Performance of Gaseous Electron Multipliers
Authors:
Erik Brücken,
Jouni Heino,
Timo Hildén,
Matti Kalliokoski,
Vladyslav Litichevskyi,
Raimo Turpeinen,
Dezső Varga
Abstract:
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size informat…
▽ More
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size information alone, it is not possible to make precise prediction of the gain. We show that the alignment of the photo-masks between the two sides of the GEM foils plays a crucial role. A misalignment of a few microns can lower the gain substantially. The study is performed by using the Helsinki high definition optical scanner for quality control of GEM foils, and this will show its true potential.
△ Less
Submitted 14 March, 2021;
originally announced March 2021.
-
The upgrade of the ALICE TPC with GEMs and continuous readout
Authors:
J. Adolfsson,
M. Ahmed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
F. Anastasopoulos,
C. Andrei,
M. Angelsmark,
V. Anguelov,
A. Anjam,
H. Appelshäuser,
V. Aprodu,
O. Arnold,
M. Arslandok,
D. Baitinger,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
P. Becht,
R. Bellwied,
A. Berdnikova,
M. Berger,
N. Bialas,
P. Bialas
, et al. (210 additional authors not shown)
Abstract:
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re…
▽ More
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.
△ Less
Submitted 25 March, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
Multispectral Photon-Counting for Medical Imaging and Beam Characterization
Authors:
E. Brücken,
S. Bharthuar,
M. Emzir,
M. Golovleva,
A. Gädda,
R. Hostettler,
J. Härkönen,
S. Kirschenmann,
V. Litichevskyi,
P. Luukka,
L. Martikainen,
T. Naaranoja,
I. Nincă,
J. Ott,
H. Petrow,
Z. Purisha,
T. Siiskonen,
S. Särkkä,
J. Tikkanen,
T. Tuuva,
A. Winkler
Abstract:
We present the current status of our project of develo** a photon counting detector for medical imaging. An example motivation lays in producing a monitoring and dosimetry device for boron neutron capture therapy, currently not commercially available. Our approach combines in-house developed detectors based on cadmium telluride or thick silicon with readout chip technology developed for particle…
▽ More
We present the current status of our project of develo** a photon counting detector for medical imaging. An example motivation lays in producing a monitoring and dosimetry device for boron neutron capture therapy, currently not commercially available. Our approach combines in-house developed detectors based on cadmium telluride or thick silicon with readout chip technology developed for particle physics experiments at CERN. Here we describe the manufacturing process of our sensors as well as the processing steps for the assembly of first prototypes. The prototypes use currently the PSI46digV2.1-r readout chip. The accompanying readout electronics chain that was used for first measurements will also be discussed. Finally we present an advanced algorithm developed by us for image reconstruction using such photon counting detectors with focus on boron neutron capture therapy. This work is conducted within a consortium of Finnish research groups from Helsinki Institute of Physics, Aalto University, Lappeenranta-Lahti University of Technology LUT and Radiation and Nuclear Safety Authority (STUK) under the RADDESS program of Academy of Finland. Keywords: Solid state detectors, X-ray detectors, Gamma detectors, Neutron detectors, Instrumentation for hadron therapy, Medical-image reconstruction methods and algorithms.
△ Less
Submitted 20 February, 2020; v1 submitted 8 January, 2020;
originally announced January 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
The GEM QA Protocol of the ALICE TPC Upgrade Project
Authors:
Jens Erik Brücken,
Timo Eero Hildén
Abstract:
The ALICE experiment at the Large Hadron Collider at CERN is upgrading its central tracking detector, the Time Projection Chamber (TPC). The installation is foreseen during the second long shutdown of the Large Hadron Collider. The upgrade includes the complete exchange of the present MWPC readout chambers (ROC) with new ones based on Gas Electron Multiplier detectors. This is necessary due to the…
▽ More
The ALICE experiment at the Large Hadron Collider at CERN is upgrading its central tracking detector, the Time Projection Chamber (TPC). The installation is foreseen during the second long shutdown of the Large Hadron Collider. The upgrade includes the complete exchange of the present MWPC readout chambers (ROC) with new ones based on Gas Electron Multiplier detectors. This is necessary due to the higher LHC luminosity and thus higher interaction rate. The new ROCs allow for continuous readout at 50 kHz compared to 500 Hz of the gated MWPC readout, while maintaining the particle identification capability of the present system. A thorough quality assurance scheme was developed to build a strict QA protocol. The QA consists of two stages. The first stage, the basic QA is done close to the GEM production workshop at CERN and later at the framing and assembly centers. The second stage, the advanced QA is done at dedicated QA centers. Full traceability of detector components will be maintained throughout the process. A detailed description of the protocol will be given with emphasis on the high definition optical scanning and gain measurements of individual GEM foils. The production of the new ALICE TPC ROCs has finally started. First QA experience under production conditions and workload will be presented.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade
Authors:
M. M. Aggarwal,
Z. Ahammed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
A. Andronic,
V. Anguelov,
H. Appelshäuser,
M. Arslandok,
R. Averbeck,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
R. Bellwied,
G. Bencedi,
M. Berger,
N. Bialas,
P. Bialas,
L. Bianchi,
S. Biswas,
L. Boldizsár,
L. Bratrud,
P. Braun-Munzinger,
M. Bregant
, et al. (155 additional authors not shown)
Abstract:
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivit…
▽ More
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d$E$/d$x$. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The d$E$/d$x$ resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.
△ Less
Submitted 17 June, 2018; v1 submitted 8 May, 2018;
originally announced May 2018.
-
Optical quality assurance of GEM foils
Authors:
T. Hildén,
E. Brücken,
J. Heino,
M. Kalliokoski,
A. Karadzhinova,
R. Lauhakangas,
E. Tuominen,
R. Turpeinen
Abstract:
An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standar…
▽ More
An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5 μm and 0.3 μm, respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain map** of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.
△ Less
Submitted 21 April, 2017;
originally announced April 2017.
-
GEM Foil Quality Assurance For The ALICE TPC Upgrade
Authors:
Erik Brücken,
Timo Hildén
Abstract:
The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second l…
▽ More
The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC) -based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz). The new ReadOut Chamber (ROC) design is based on Gas Electron Multiplier (GEM) technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA) measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.
△ Less
Submitted 20 April, 2017;
originally announced April 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
A gaseous proportional counter built from a conventional aluminium beverage can
Authors:
Alexander Winkler,
Aneliya Karadzhinova,
Timo Hildén,
Francisco Garcia,
Giacomo Fedi,
Francesco Devoto,
Erik J. Brücken
Abstract:
The gaseous proportional counter is a device that can be used to detect ionizing radiation. These devices can be as simple as a cylindrical cathode and a very thin anode wire centered along its axis. By applying a high voltage, a strong electric field is generated close to the anode wire. Ion-pairs, generated by passing ionizing radiation, create avalanches once they drift into the strong electric…
▽ More
The gaseous proportional counter is a device that can be used to detect ionizing radiation. These devices can be as simple as a cylindrical cathode and a very thin anode wire centered along its axis. By applying a high voltage, a strong electric field is generated close to the anode wire. Ion-pairs, generated by passing ionizing radiation, create avalanches once they drift into the strong electric field region near the anode. The electrical charges created by the avalanche generate an observable signal which is proportional to the energy loss of the incoming radiation. We discuss the construction of such a device. Our detector was built from an ordinary aluminium beverage can and uses a common electric wire strand as the anode. The construction of this detector offers students at universities or technically oriented high schools a detailed understanding of the design and operation of gaseous radiation detectors. The equipment required to complete the project should be available at most institutions.
△ Less
Submitted 2 February, 2024; v1 submitted 8 September, 2015;
originally announced September 2015.
-
LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (54 additional authors not shown)
Abstract:
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport…
▽ More
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.
△ Less
Submitted 2 June, 2014;
originally announced June 2014.
-
Performance of the TOTEM Detectors at the LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
R. Cecchi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (57 additional authors not shown)
Abstract:
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi…
▽ More
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.