-
Imaging and structure analysis of ferroelectric domains, domain walls, and vortices by scanning electron diffraction
Authors:
Ursula Ludacka,
Jiali He,
Shuyu Qin,
Manuel Zahn,
Emil Frang Christiansen,
Kasper A. Hunnestad,
Zewu Yan,
Edith Bourret,
István Kézsmárki,
Antonius T. J. van Helvoort,
Joshua Agar,
Dennis Meier
Abstract:
Direct electron detectors in scanning transmission electron microscopy give unprecedented possibilities for structure analysis at the nanoscale. In electronic and quantum materials, this new capability gives access to, for example, emergent chiral structures and symmetry-breaking distortions that underpin functional properties. Quantifying nanoscale structural features with statistical significanc…
▽ More
Direct electron detectors in scanning transmission electron microscopy give unprecedented possibilities for structure analysis at the nanoscale. In electronic and quantum materials, this new capability gives access to, for example, emergent chiral structures and symmetry-breaking distortions that underpin functional properties. Quantifying nanoscale structural features with statistical significance, however, is complicated by the subtleties of dynamic diffraction and coexisting contrast mechanisms, which often results in low signal-to-noise and the superposition of multiple signals that are challenging to deconvolute. Here we apply scanning electron diffraction to explore local polar distortions in the uniaxial ferroelectric Er(Mn,Ti)O$_3$. Using a custom-designed convolutional autoencoder with bespoke regularization, we demonstrate that subtle variations in the scattering signatures of ferroelectric domains, domain walls, and vortex textures can readily be disentangled with statistical significance and separated from extrinsic contributions due to, e.g., variations in specimen thickness or bending. The work demonstrates a pathway to quantitatively measure symmetry-breaking distortions across large areas, map** structural changes at interfaces and topological structures with nanoscale spatial resolution.
△ Less
Submitted 9 May, 2023;
originally announced May 2023.
-
A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments
Authors:
T. Akindele,
T. Anderson,
E. Anderssen,
M. Askins,
M. Bohles,
A. J. Bacon,
Z. Bagdasarian,
A. Baldoni,
A. Barna,
N. Barros,
L. Bartoszek,
A. Bat,
E. W. Beier,
T. Benson,
M. Bergevin,
A. Bernstein,
B. Birrittella,
E. Blucher,
J. Boissevain,
R. Bonventre,
J. Borusinki,
E. Bourret,
D. Brown,
E. J. Callaghan,
J. Caravaca
, et al. (140 additional authors not shown)
Abstract:
The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts.
Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security…
▽ More
The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts.
Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors.
In parallel, the fundamental physics community has been develo** detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others.
Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations.
Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.
△ Less
Submitted 20 April, 2022; v1 submitted 28 February, 2022;
originally announced March 2022.
-
Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator
Authors:
Gino Gabella,
Bethany L. Goldblum,
Thibault A. Laplace,
Juan J. Manfredi,
Joseph Gordon,
Zachary W. Sweger,
Edith Bourret
Abstract:
Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5% natural boron loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron r…
▽ More
Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5% natural boron loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV $γ$ ray (resulting from deexcitation of the residual $^{7}$Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from $γ$-ray and fast/slow neutron interactions. Clear separation between $γ$-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the $γ$-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron-capture light yield in EJ-254 was determined to be 89.4$\pm$1.1 keVee.
△ Less
Submitted 6 January, 2021;
originally announced January 2021.
-
Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass
Authors:
T. A. Laplace,
B. L. Goldblum,
J. E. Bevins,
D. L. Bleuel,
E. Bourret,
J. A. Brown,
E. J. Callaghan,
J. S. Carlson,
P. L. Feng,
G. Gabella,
K. P. Harrig,
J. J. Manfredi,
C. Moore,
F. Moretti,
M. Shinner,
A. Sweet,
Z. W. Sweger
Abstract:
An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the $^{137}$Cs Compton edge location. The proton light yield was measured…
▽ More
An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the $^{137}$Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV$-$3.2 MeV), EJ-276 (170 keV$-$4.9 MeV), and the organic glass (50 keV$-$20 MeV). Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. With these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.
△ Less
Submitted 3 November, 2020;
originally announced November 2020.
-
Intrinsic and extrinsic conduction contributions at nominally neutral domain walls in hexagonal manganites
Authors:
J. Schultheiß,
J. Schaab,
D. R. Småbråten,
S. H. Skjærvø,
E. Bourret,
Z. Yan,
S. M. Selbach,
D. Meier
Abstract:
Conductive and electrostatic atomic force microscopy (cAFM and EFM) are used to investigate the electric conduction at nominally neutral domain walls in hexagonal manganites. The EFM measurements reveal a propensity of mobile charge carriers to accumulate at the nominally neutral domain walls in ErMnO3, which is corroborated by cAFM scans showing locally enhanced d.c. conductance. Our findings are…
▽ More
Conductive and electrostatic atomic force microscopy (cAFM and EFM) are used to investigate the electric conduction at nominally neutral domain walls in hexagonal manganites. The EFM measurements reveal a propensity of mobile charge carriers to accumulate at the nominally neutral domain walls in ErMnO3, which is corroborated by cAFM scans showing locally enhanced d.c. conductance. Our findings are explained based on established segregation enthalpy profiles for oxygen vacancies and interstitials, providing a microscopic model for previous, seemingly disconnected observations ranging from insulating to conducting domain wall behavior. In addition, we observe variations in conductance between different nominally neutral walls that we attribute to deviations from the ideal charge-neutral structure within the bulk, leading to a superposition of extrinsic and intrinsic contributions. Our study clarifies the complex transport properties at nominally neutral domain walls in hexagonal manganites and establishes new possibilities for tuning their electronic response based on oxidation conditions, opening the door for domain-wall based sensor technology.
△ Less
Submitted 30 March, 2020; v1 submitted 27 March, 2020;
originally announced March 2020.
-
Time Response of Water-based Liquid Scintillator from X-ray Excitation
Authors:
Drew R. Onken,
Federico Moretti,
Javier Caravaca,
Minfang Yeh,
Gabriel D. Orebi Gann,
Edith D. Bourret
Abstract:
Water-based liquid scintillators (WbLS) present an attractive target medium for large-scale detectors with the ability to enhance the separation of Cherenkov and scintillation signals from a single target. This work characterizes the scintillation properties of WbLS samples based on LAB/PPO liquid scintillator (LS). X-ray luminescence spectra, decay profiles, and relative light yields are measured…
▽ More
Water-based liquid scintillators (WbLS) present an attractive target medium for large-scale detectors with the ability to enhance the separation of Cherenkov and scintillation signals from a single target. This work characterizes the scintillation properties of WbLS samples based on LAB/PPO liquid scintillator (LS). X-ray luminescence spectra, decay profiles, and relative light yields are measured for WbLS of varying LS concentration as well as for pure LS with a range of PPO concentrations up to 90 g/L. The scintillation properties of the WbLS are related to the precursor LAB/PPO: starting from 90 g/L PPO in LAB before synthesis, the resulting WbLS have spectroscopic properties that instead match 10 g/L PPO in LAB. This could indicate that the concentration of active PPO in the WbLS samples depends on their processing.
△ Less
Submitted 23 March, 2020;
originally announced March 2020.
-
GaAs as a bright cryogenic scintillator for the direct dark matter detection
Authors:
S. Vasiukov,
F. Chiossi,
C. Braggio,
G. Carugno,
F. Moretti,
E. Bourret,
S. Derenzo
Abstract:
The optical and scintillation properties of undoped, Si-doped, and Si, B co-doped GaAs samples were studied. The light yield specification and X-ray luminescence of GaAs over a wide IR region by using Si and InGaAs photodetectors are presented. The undoped GaAs demonstrated a narrow emission band at 838 nm (1.48 eV) and a low light output of about 2 ph/keV. The GaAs:Si is characterized by three br…
▽ More
The optical and scintillation properties of undoped, Si-doped, and Si, B co-doped GaAs samples were studied. The light yield specification and X-ray luminescence of GaAs over a wide IR region by using Si and InGaAs photodetectors are presented. The undoped GaAs demonstrated a narrow emission band at 838 nm (1.48 eV) and a low light output of about 2 ph/keV. The GaAs:Si is characterized by three broad luminescence bands at 830 nm (1.49 eV), 1070 nm (1.16 eV), 1335 nm (0.93 eV) and a light output of about 71 ph/keV. In the case of GaAs:(Si, B), four luminescence bands at 860 nm (1.44 eV), 930 nm (1.33 eV), 1070 nm (1.16 eV) and 1335 nm (0.93 eV) were observed. A high light yield higher than 125 ph/keV was estimated for the co-doped sample. The applications of low energy gap semiconductors as cryogenic scintillators for particle detection are discussed. The GaAs is a promising crystal for a cryogenic scintillator for the dark matter (DM) detection.
△ Less
Submitted 19 April, 2019;
originally announced April 2019.
-
Cryogenic Scintillation Properties of n-Type GaAs for the Direct Detection of MeV/c2 Dark Matter
Authors:
S. Derenzo,
E. Bourret,
S. Hanrahan,
G. Bizarri
Abstract:
This paper is the first report of n-type GaAs as a cryogenic scintillation radiation detector for the detection of electron recoils from interacting dark matter (DM) particles in the poorly explored MeV/c2 mass range. Seven GaAs samples from two commercial suppliers and with different silicon and boron concentrations were studied for their low temperature optical and scintillation properties. All…
▽ More
This paper is the first report of n-type GaAs as a cryogenic scintillation radiation detector for the detection of electron recoils from interacting dark matter (DM) particles in the poorly explored MeV/c2 mass range. Seven GaAs samples from two commercial suppliers and with different silicon and boron concentrations were studied for their low temperature optical and scintillation properties. All samples are n-type even at low temperatures and exhibit emission between silicon donors and boron acceptors that peaks at 1.33 eV (930 nm). The lowest excitation band peaks at 1.44 eV (860 nm) and the overlap between the emission and excitation bands is small. The X-ray excited luminosities range from 7 to 43 photons/keV. Thermally stimulated luminescence measurements show that n-type GaAs does not accumulate metastable radiative states that could cause afterglow. Further development and use with cryogenic photodetectors promises a remarkable combination of large target size, ultra-low backgrounds, and a sensitivity to electron recoils of a few eV that would be produced by DM particles as light as a few MeV/c2.
△ Less
Submitted 26 February, 2018;
originally announced February 2018.