Microwave Cavity Mode Optimisation by Background Anti-Resonance Tuning
Authors:
Michael T. Hatzon,
Eugene N. Ivanov,
Jeremy F. Bourhill,
Maxim Goryachev,
Michael E. Tobar
Abstract:
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high…
▽ More
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high contrast and symmetry can be achieved by changing the dimensions of the surrounding cavity shield to tune the background low-Q structures into anti-resonance. This works because the high-Q resonances are primarily defined by the sapphire while the background modes are defined by the cavity shield. Alternatively, it was shown that a similar result can be achieved by exciting the high-Q resonator with a balanced microwave dipole probe in a Mach Zehnder interferometric configuration. The probe was constructed from two separate coaxial electric field probes symmetrically inserted into a cylindrical cavity resonator, from opposite sides with a small gap between them, so they can behave like an active wire dipole antenna. The power into the two separate probes may be matched with an external variable attenuator in one of the arms of the interferometer. Conversely, the phase between the two electric field probes may be changed with an external variable phase shifter, which changes the nature of the field components the probe couples to. The probe couples to the high-Q resonant modes as well as low-Q background modes, which can be made resonant or anti-resonant for the high-Q modes by changing this external phase. When the background modes are in anti-resonance the line shape of the high-Q mode can be made symmetric and with higher contrast. This technique was applied to both whispering gallery sapphire modes, as well as hollow cavity resonators, without changing the dimensions of the cavity.
△ Less
Submitted 25 April, 2024;
originally announced May 2024.
-
Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves
Authors:
Michael E. Tobar,
Catriona A. Thomson,
William M. Campbell,
Aaron Quiskamp,
Jeremy F. Bourhill,
Benjamin T. McAllister,
Eugene N. Ivanov,
Maxim Goryachev
Abstract:
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon thet…
▽ More
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.
△ Less
Submitted 16 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Searching for Ultra-Light Axions with Twisted Cavity Resonators of Anyon Rotational Symmetry with Bulk Modes of Non-Zero Helicity
Authors:
J. F. Bourhill,
E. C. I. Paterson,
M. Goryachev,
M. E. Tobar
Abstract:
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow…
▽ More
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow structures using equilateral triangular cross-sections, which leads to the realization of a cavity with anyon rotational symmetry. Unlike all previous cavity resonators, the anyon resonator permits the existence of bulk resonant modes that exhibit non-zero electromagnetic helicity in vacuo, with a non-zero overlap of the electric and magnetic mode eigenvectors, $\int \mathbf{E}_p\cdot\mathbf{B}_p~dτ$, integrated over the cavity volume. In the upconversion limit, we show that these non-zero helical modes couple naturally to ultra-light dark matter axions within the bandwidth of the resonator by adding amplitude-modulated sidebands through the axion-photon chiral anomaly. Thus, we show a sensitive ultra-light dark matter experiment may be realized by implementing such a resonator in an ultra-stable oscillator configuration and searching for signals in the Fourier spectrum of amplitude fluctuations. This removes the typical requirement for an external magnetic field and therefore permits the use of superconducting materials to reduce surface losses and enhance sensitivity to axions.
△ Less
Submitted 9 August, 2023; v1 submitted 1 August, 2022;