-
Theoretical study of the I$^{+}$ + I$^{-}$ mutual neutralization reaction
Authors:
Sylvain Badin,
Xiang Yuan,
Pierre-Louis Bourgeois,
Andre Severo Pereira Gomes,
Nicolas Sisourat
Abstract:
We have computed the cross sections of the mutual neutralization reaction between I$^{+}$ and I$^{-}$ for a collision energy varying from 0.001 eV to 50 eV. These cross sections were obtained using the adiabatic potential energy curves of the I$_{2}$ system computed with a direct relativistic Multi-Reference Configuration Interaction method and a semi-classical approach (i.e. Landau Zener Surface…
▽ More
We have computed the cross sections of the mutual neutralization reaction between I$^{+}$ and I$^{-}$ for a collision energy varying from 0.001 eV to 50 eV. These cross sections were obtained using the adiabatic potential energy curves of the I$_{2}$ system computed with a direct relativistic Multi-Reference Configuration Interaction method and a semi-classical approach (i.e. Landau Zener Surface Hop**). We report the cross sections towards the following neutral states: $\text{I}(^{2}P_{3/2})+\text{I}(^{2}P_{3/2})$, $\text{I}(^{2}P_{3/2})+\text{I}(^{2}P_{1/2})$, $\text{I}(^{2}P_{1/2})+\text{I}(^{2}P_{1/2})$ and $\text{I}(5p^{4}6s)+\text{I}(^{2}P_{3/2})$. We also discuss the cross sections towards the two following excited ionic states : $\text{I}^{-}(^{1}S_{0})+\text{I}^{+}(^{3}P_{0})$ and $\text{I}^{-}(^{1}S_{0})+\text{I}^{+}(^{3}D_{2})$. The results of these calculations are in accordance with recent experimental measurements conducted in the double ion ring DESIREE in Stockholm. These results can be used to model iodine plasma kinetics and thus to improve our understanding of the latter.
△ Less
Submitted 10 November, 2022;
originally announced November 2022.
-
Residual Phase Noise Measurement of Optical Second Harmonic Generation in PPLN Waveguides
Authors:
Marion Delehaye,
Jacques Millo,
Pierre-Yves Bourgeois,
Lucas Groult,
Rodolphe Boudot,
Enrico Rubiola,
Emmanuel Bigler,
Yann Kersalé,
Clément Lacroûte
Abstract:
We report on the characterization, including residual phase noise and fractional frequency instability, of fiber-coupled PPLN non-linear crystals. These components are devoted to frequency doubling 871 nm light from an extended-cavity diode laser to produce a 435.5 nm beam, corresponding to the ytterbium ion electric quadrupole clock transition. We measure doubling efficiencies of up to 117.5 %/W.…
▽ More
We report on the characterization, including residual phase noise and fractional frequency instability, of fiber-coupled PPLN non-linear crystals. These components are devoted to frequency doubling 871 nm light from an extended-cavity diode laser to produce a 435.5 nm beam, corresponding to the ytterbium ion electric quadrupole clock transition. We measure doubling efficiencies of up to 117.5 %/W. Using a Mach-Zehnder interferometer and an original noise rejection technique, the residual phase noise of the doublers is estimated to be lower than ${\rm -35\, dBrad^2/Hz}$ at 1 Hz, making these modules compatible with up-to-date optical clocks and ultra-stable cavities. The influence of external parameters such as pump laser frequency and intensity is investigated, showing that they do not limit the stability of the frequency-doubled signal. Our results demonstrate that such compact, fiber-coupled modules are suitable for use in ultra-low phase noise metrological experiments, including transportable optical atomic clocks.
△ Less
Submitted 11 July, 2017;
originally announced July 2017.
-
Compact Yb$^+$ optical atomic clock project: design principle and current status
Authors:
Clément Lacroûte,
Maël Souidi,
Pierre-Yves Bourgeois,
Jacques Millo,
Khaldoun Saleh,
Emmanuel Bigler,
Rodolphe Boudot,
Vincent Giordano,
Yann Kersalé
Abstract:
We present the design of a compact optical clock based on the $^2S_{1/2} \rightarrow ^2D_{3/2}$ 435.5 nm transition in $^{171}$Yb$^+$. The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trap** potential to localize a single Yb ion a few hundred $μ$m from the electrodes. We present our trap design as well as simulations of the resulting trap** pseudo-…
▽ More
We present the design of a compact optical clock based on the $^2S_{1/2} \rightarrow ^2D_{3/2}$ 435.5 nm transition in $^{171}$Yb$^+$. The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trap** potential to localize a single Yb ion a few hundred $μ$m from the electrodes. We present our trap design as well as simulations of the resulting trap** pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repum** and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.
△ Less
Submitted 18 March, 2016;
originally announced March 2016.
-
The Omega Counter, a Frequency Counter Based on the Linear Regression
Authors:
E. Rubiola,
M. Lenczner,
P. -Y. Bourgeois,
F. Vernotte
Abstract:
This article introduces the Ω counter, a frequency counter -- or a frequency-to-digital converter, in a different jargon -- based on the Linear Regression (LR) algorithm on time stamps. We discuss the noise of the electronics. We derive the statistical properties of the Ω counter on rigorous mathematical basis, including the weighted measure and the frequency response. We describe an implementatio…
▽ More
This article introduces the Ω counter, a frequency counter -- or a frequency-to-digital converter, in a different jargon -- based on the Linear Regression (LR) algorithm on time stamps. We discuss the noise of the electronics. We derive the statistical properties of the Ω counter on rigorous mathematical basis, including the weighted measure and the frequency response. We describe an implementation based on a SoC, under test in our laboratory, and we compare the Ω counter to the traditional Π and Λ counters. The LR exhibits optimum rejection of white phase noise, superior to that of the Π and Λ counters. White noise is the major practical problem of wideband digital electronics, both in the instrument internal circuits and in the fast processes which we may want to measure. The Ω counter finds a natural application in the measurement of the Parabolic Variance, described in the companion article arXiv:1506.00687 [physics.data-an].
△ Less
Submitted 16 June, 2015;
originally announced June 2015.
-
The Parabolic variance (PVAR), a wavelet variance based on least-square fit
Authors:
F. Vernotte,
M. Lenczner,
P. -Y. Bourgeois,
E. Rubiola
Abstract:
This article introduces the Parabolic Variance (PVAR), a wavelet variance similar to the Allan variance, based on the Linear Regression (LR) of phase data. The companion article arXiv:1506.05009 [physics.ins-det] details the $Ω$ frequency counter, which implements the LR estimate.
The PVAR combines the advantages of AVAR and MVAR. PVAR is good for long-term analysis because the wavelet spans ove…
▽ More
This article introduces the Parabolic Variance (PVAR), a wavelet variance similar to the Allan variance, based on the Linear Regression (LR) of phase data. The companion article arXiv:1506.05009 [physics.ins-det] details the $Ω$ frequency counter, which implements the LR estimate.
The PVAR combines the advantages of AVAR and MVAR. PVAR is good for long-term analysis because the wavelet spans over $2 τ$, the same of the AVAR wavelet; and good for short-term analysis because the response to white and flicker PM is $1/τ^3$ and $1/τ^2$, same as the MVAR.
After setting the theoretical framework, we study the degrees of freedom and the confidence interval for the most common noise types. Then, we focus on the detection of a weak noise process at the transition - or corner - where a faster process rolls off. This new perspective raises the question of which variance detects the weak process with the shortest data record. Our simulations show that PVAR is a fortunate tradeoff. PVAR is superior to MVAR in all cases, exhibits the best ability to divide between fast noise phenomena (up to flicker FM), and is almost as good as AVAR for the detection of random walk and drift.
△ Less
Submitted 27 October, 2015; v1 submitted 1 June, 2015;
originally announced June 2015.
-
Influence of the ESR saturation on the power sensitivity of cryogenic sapphire resonators
Authors:
Vincent Giordano,
Serge Grop,
Pierre-Yves Bourgeois,
Yann Kersalé,
Enrico Rubiola
Abstract:
Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now achieved by comparing two CSOs permit for the first time to observe clearly the non-linearity of the resonator power sensitivity. These observations that in turn allow…
▽ More
Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now achieved by comparing two CSOs permit for the first time to observe clearly the non-linearity of the resonator power sensitivity. These observations that in turn allow us to optimize the CSO operation, are well explained by the Electron Spin Resonance (ESR) saturation of the paramagnetic impurities contained in the sapphire crystal.
△ Less
Submitted 13 May, 2014;
originally announced May 2014.
-
Controlling the Frequency-Temperature Sensitivity of a Cryogenic Sapphire Maser Frequency Standard by Manipulating Fe3+ Spins in the Sapphire Lattice
Authors:
Karim Benmessai,
Daniel L. Creedon,
Mohamad Mrad,
Jean-Michel Le Floch,
Pierre-Yves Bourgeois,
Yann Kersalé,
Vincent Giordano,
Michael E. Tobar
Abstract:
To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting Whispering Gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3+ ions in the sapphire lattice. We show that the maser signal depends on other Whispering Gallery modes tuned to the pump…
▽ More
To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting Whispering Gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3+ ions in the sapphire lattice. We show that the maser signal depends on other Whispering Gallery modes tuned to the pump signal near 31 GHz, and the annulment point can be controlled to exist between 5 to 10 K depending on the Fe3+ ion concentration and the frequency of the pump. This level of control has not been achieved previously, and will allow improvements in the stability of such devices.
△ Less
Submitted 16 January, 2012;
originally announced January 2012.
-
Fe3+ paramagnetic ion in α-Al2 O3 energy levels revisited. Application to a 31 GHz Maser proposal
Authors:
M. Mrad,
P. Y. Bourgeois,
Y. Kersalé,
V. Giordano
Abstract:
The molecular structure of a 3d 5 configuration ion in a trigonal ligand field is theoretically established on the basis of the 252\times252 complete energy matrice. The optical absorption and the electron paramagnetic resonance spectra of the Fe3+ ion in the sapphire crystal (α-Al2 O3) have been studied by diagonalizing the complete energy matrice. The calculated results are in very good agreemen…
▽ More
The molecular structure of a 3d 5 configuration ion in a trigonal ligand field is theoretically established on the basis of the 252\times252 complete energy matrice. The optical absorption and the electron paramagnetic resonance spectra of the Fe3+ ion in the sapphire crystal (α-Al2 O3) have been studied by diagonalizing the complete energy matrice. The calculated results are in very good agreement with previous experimental observations. The strength of the transition probabilities between pairs of the energy levels have been calculated to determine the possibility to achieve a population inversion in the ground state by applying optical pum** to the crystal. Preliminary results based on the computed transition parameters and on the maser rate equations model show that a 31 GHz maser signal can be effectively generated depending on the cryogenic resonator design.
△ Less
Submitted 9 January, 2012;
originally announced January 2012.
-
Unprecedented High Long Term Frequency Stability with a Macroscopic Resonator Oscillator
Authors:
Serge Grop,
Wolfgang Schäfer,
Pierre-Yves Bourgeois,
Nicolas Bazin,
Yann Kersalé,
Mark Oxborrow,
Enrico Rubiola,
Vincent Giordano
Abstract:
This article reports on the long-term frequency stabilty characterisation of a new type of cryogenic sapphire oscillator using an autonomous pulse-tube cryocooler as its cold source. This new design enables a relative frequency stability of better than 4.5e-15 over one day of integration. This represents to our knowledge the best long-term frequency stability ever obtained with a signal source bas…
▽ More
This article reports on the long-term frequency stabilty characterisation of a new type of cryogenic sapphire oscillator using an autonomous pulse-tube cryocooler as its cold source. This new design enables a relative frequency stability of better than 4.5e-15 over one day of integration. This represents to our knowledge the best long-term frequency stability ever obtained with a signal source based on a macroscopic resonator.
△ Less
Submitted 3 November, 2010;
originally announced November 2010.
-
DC-powered Fe3+:sapphire Maser and its Sensitivity to Ultraviolet Light
Authors:
Mark Oxborrow,
Pierre-Yves Bourgeois,
Yann Kersalé,
Vincent Giordano
Abstract:
The zero-field Fe3+:sapphire whispering-gallery-mode maser oscillator exhibits several alluring features: Its output is many orders of magnitude brighter than that of an active hydrogen maser and thus far less degraded by spontaneous-emission (Schawlow-Townes) and/or receiving-amplifier noise. Its oscillator loop is confined to a piece of mono-crystalline rock bolted into a metal can. Its quiet am…
▽ More
The zero-field Fe3+:sapphire whispering-gallery-mode maser oscillator exhibits several alluring features: Its output is many orders of magnitude brighter than that of an active hydrogen maser and thus far less degraded by spontaneous-emission (Schawlow-Townes) and/or receiving-amplifier noise. Its oscillator loop is confined to a piece of mono-crystalline rock bolted into a metal can. Its quiet amplification combined with high resonator Q provide the ingredients for exceptionally low phase noise. We here concentrate on novelties addressing the fundamental conundrums and technical challenges that impede progress. (1) Roasting: The "mase-ability" of sapphire depends significantly on the chemical conditions under which it is grown and heat-treated. We provide some fresh details and nuances here. (2) Simplification: This paper obviates the need for a Ka-band synthesizer: it describes how a 31.3 GHz loop oscillator, operating on the preferred WG pump mode, incorporating Pound locking, was built from low-cost components. (3) "Dark Matter": A Siegman-level analysis of the experimental data determines the substitutional concentration of Fe3+ in HEMEX to be less than a part per billion prior to roasting and up to a few hundred ppb afterwards. Chemical assays, using different techniques (incl. glow discharge mass spectra spectroscopy and neutron activation analysis) consistently indicate, however, that HEMEX contains iron at concentrations of a few parts per million. Drawing from several forgotten-about/under-appreciated papers, this substantial discrepancy is addressed. (4) Excitons: Towards providing a new means of controlling the Fe3+:sapph. system, a cryogenic sapphire ring was illuminated, whilst masing, with UV light at wavelengths corresponding to known electronic and charge-transfer (thus valence-altering) transitions. Preliminary experiments are reported.
△ Less
Submitted 26 April, 2010; v1 submitted 23 April, 2010;
originally announced April 2010.
-
ELISA: a cryocooled 10 GHz oscillator with 10-15 frequency stability
Authors:
S. Grop,
P. Y. Bourgeois,
N. Bazin,
Y. Kersale,
E. Rubiola,
C. Langham,
M. Oxborrow,
D. Clapton,
S. Walker,
J. De Vicente,
V. Giordano
Abstract:
This article reports the design, the breadboarding and the validation of an ultra-stable Cryogenic Sapphire Oscillator operated in an autonomous cryocooler. The objective of this project was to demonstrate the feasibility of a frequency stability of 3x10-15 between 1 s and 1,000 s for the European Space Agency deep space stations. This represents the lowest fractional frequency instability ever…
▽ More
This article reports the design, the breadboarding and the validation of an ultra-stable Cryogenic Sapphire Oscillator operated in an autonomous cryocooler. The objective of this project was to demonstrate the feasibility of a frequency stability of 3x10-15 between 1 s and 1,000 s for the European Space Agency deep space stations. This represents the lowest fractional frequency instability ever achieved with cryocoolers. The preliminary results presented in this paper validate the design we adopted for the sapphire resonator, the cold source and the oscillator loop.
△ Less
Submitted 22 September, 2009;
originally announced September 2009.
-
Ultra-Low Noise Microwave Extraction from Fiber-Based Optical Frequency Comb
Authors:
J. Millo,
R. Boudot,
M. Lours,
P. Y. Bourgeois,
A. N. Luiten,
Y. Le Coq,
Y. Kersale,
G. Santarelli
Abstract:
In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived f…
▽ More
In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived from the two optical frequency combs is below 2.3 10^(-16) at 1s and about 4 10^(-19) at 6.5 10^(4)s (in 5 Hz bandwidth, three days continuous operation).
△ Less
Submitted 21 November, 2009; v1 submitted 25 June, 2009;
originally announced June 2009.
-
Creating traveling waves from standing waves from the gyrotropic paramagnetic properties of Fe$^{3+}$ ions in a high-Q whispering gallery mode sapphire resonator
Authors:
Karim Benmessai,
Michael Edmund Tobar,
Nicholas Bazin,
Pierre-Yves Bourgeois,
Yann Kersale,
Vincent Giordano
Abstract:
We report observations of the gyrotropic change in magnetic susceptibility of the Fe$^{3+}$ electron paramagnetic resonance at 12.037GHz (between spin states $|1/2>$ and $|3/2>$) in sapphire with respect to applied magnetic field. Measurements were made by observing the response of the high-Q Whispering Gallery doublet (WGH$_{\pm17,0,0}$) in a Hemex sapphire resonator cooled to 5 K. The doublets…
▽ More
We report observations of the gyrotropic change in magnetic susceptibility of the Fe$^{3+}$ electron paramagnetic resonance at 12.037GHz (between spin states $|1/2>$ and $|3/2>$) in sapphire with respect to applied magnetic field. Measurements were made by observing the response of the high-Q Whispering Gallery doublet (WGH$_{\pm17,0,0}$) in a Hemex sapphire resonator cooled to 5 K. The doublets initially existed as standing waves at zero field and were transformed to traveling waves due to the gyrotropic response.
△ Less
Submitted 21 May, 2009;
originally announced May 2009.
-
Measurement of fundamental thermal noise limit in a cryogenic sapphire frequency standard using bimodal maser oscillations
Authors:
Karim Benmessai,
Daniel Lloyd Creedon,
Michael Edmund Tobar,
Pierre-Yves Bourgeois,
Yann Kersale,
Vincent Giordano
Abstract:
We report observations of the Schawlow-Townes noise limit in a cryogenic sapphire secondary frequency standard. The effect causes a fundamental limit to the frequency stability, and was measured through the novel excitation of a bimodal maser oscillation of a Whispering Gallery doublet at $12.04 GHz$. The beat frequency of $10 kHz$ between the oscillations enabled a sensitive probe for this meas…
▽ More
We report observations of the Schawlow-Townes noise limit in a cryogenic sapphire secondary frequency standard. The effect causes a fundamental limit to the frequency stability, and was measured through the novel excitation of a bimodal maser oscillation of a Whispering Gallery doublet at $12.04 GHz$. The beat frequency of $10 kHz$ between the oscillations enabled a sensitive probe for this measurement of fractional frequency instability of $10^{-14}τ^{-1/2}$ with only 0.5 $pW$ of output power.
△ Less
Submitted 16 July, 2008;
originally announced July 2008.