-
STRASSE: A Silicon Tracker for Quasi-free Scattering Measurements at the RIBF
Authors:
H. N. Liu,
F. Flavigny,
H. Baba,
M. Boehmer,
U. Bonnes,
V. Borshchov,
P. Doornenbal,
N. Ebina,
M. Enciu,
A. Frotscher,
R. Gernhäuser,
V. Girard-Alcindor,
D. Goupillière,
J. Heuser,
R. Kapell,
Y. Kondo,
H. Lee,
J. Lehnert,
T. Matsui,
A. Matta,
T. Nakamura,
A. Obertelli,
T. Pohl,
M. Protsenko,
M. Sasano
, et al. (13 additional authors not shown)
Abstract:
STRASSE (Silicon Tracker for RAdioactive nuclei Studies at SAMURAI Experiments) is a new detection system under construction for quasi-free scattering (QFS) measurements at 200-250 MeV/nucleon at the RIBF facility of the RIKEN Nishina Center. It consists of a charged-particle silicon tracker coupled with a dedicated thick liquid hydrogen target (up to 150-mm long) in a compact geometry to fit insi…
▽ More
STRASSE (Silicon Tracker for RAdioactive nuclei Studies at SAMURAI Experiments) is a new detection system under construction for quasi-free scattering (QFS) measurements at 200-250 MeV/nucleon at the RIBF facility of the RIKEN Nishina Center. It consists of a charged-particle silicon tracker coupled with a dedicated thick liquid hydrogen target (up to 150-mm long) in a compact geometry to fit inside large scintillator or germanium arrays. Its design was optimized for two types of studies using QFS: missing-mass measurements and in-flight prompt $γ$-ray spectroscopy. This article describes (i) the resolution requirements needed to go beyond the sensitivity of existing systems for these two types of measurements, (ii) the conceptual design of the system using detailed simulations of the setup and (iii) its complete technical implementation and challenges. The final tracker aims at a sub-mm reaction vertex resolution and is expected to reach a missing-mass resolution below 2 MeV in $σ$ for $(p,2p)$ reactions when combined with the CsI(Na) CATANA array.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
New data acquisition system of the Lintott magnetic spectrometer at the S-DALINAC
Authors:
M. Singer,
U. Bonnes,
A. D'Alessio,
M. Hilcker,
P. von Neumann-Cosel,
N. Pietralla
Abstract:
A new data acquisition system for the high resolution magnetic spectrometer Lintott at the superconducting Darmstadt electron linear accelerator S-DALINAC was developed. It allows inclusive and coincidence electron scattering experiments with event rates up to 10 kHz.
A new data acquisition system for the high resolution magnetic spectrometer Lintott at the superconducting Darmstadt electron linear accelerator S-DALINAC was developed. It allows inclusive and coincidence electron scattering experiments with event rates up to 10 kHz.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
The PreAmplifier ShAper for the ALICE TPC-Detector
Authors:
H. K. Soltveit,
J. Stachel,
P. Braun-Munzinger,
L. Musa,
H. A. Gustafsson,
U. Bonnes,
H. Oeschler,
L. Osterman,
S. Lang
Abstract:
In this paper the PreAmplifier ShAper (PASA) for the Time Projection Chamber (TPC) of the ALICE experiment at LHC is presented. The ALICE TPC PASA is an ASIC that integrates 16 identical channels, each consisting of Charge Sensitive Amplifiers (CSA) followed by a Pole-Zero network, self-adaptive bias network, two second-order bridged-T filters, two non-inverting level shifters and a start-up circu…
▽ More
In this paper the PreAmplifier ShAper (PASA) for the Time Projection Chamber (TPC) of the ALICE experiment at LHC is presented. The ALICE TPC PASA is an ASIC that integrates 16 identical channels, each consisting of Charge Sensitive Amplifiers (CSA) followed by a Pole-Zero network, self-adaptive bias network, two second-order bridged-T filters, two non-inverting level shifters and a start-up circuit. The circuit is optimized for a detector capacitance of 18-25 pF. For an input capacitance of 25 pF, the PASA features a conversion gain of 12.74 mV/fC, a peaking time of 160 ns, a FWHM of 190 ns, a power consumption of 11.65 mW/ch and an equivalent noise charge of 244e + 17e/pF. The circuit recovers smoothly to the baseline in about 600 ns. An integral non-linearity of 0.19% with an output swing of about 2.1 V is also achieved. The total area of the chip is 18 mm$^2$ and is implemented in AMS's C35B3C1 0.35 micron CMOS technology. Detailed characterization test were performed on about 48000 PASA circuits before mounting them on the ALICE TPC front-end cards. After more than two years of operation of the ALICE TPC with p-p and Pb-Pb collisions, the PASA has demonstrated to fulfill all requirements.
△ Less
Submitted 15 March, 2012;
originally announced March 2012.
-
The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
Authors:
J. Alme,
Y. Andres,
H. Appelshauser,
S. Bablok,
N. Bialas,
R. Bolgen,
U. Bonnes,
R. Bramm,
P. Braun-Munzinger,
R. Campagnolo,
P. Christiansen,
A. Dobrin,
C. Engster,
D. Fehlker,
P. Foka,
U. Frankenfeld,
J. J. Gaardhoje,
C. Garabatos,
P. Glassel,
C. Gonzalez Gutierrez,
P. Gros,
H. -A. Gustafsson,
H. Helstrup,
M. Hoch,
M. Ivanov
, et al. (51 additional authors not shown)
Abstract:
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we des…
▽ More
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.
△ Less
Submitted 12 January, 2010;
originally announced January 2010.