-
Variable Energy X-ray Fluorescence Source
Authors:
S. R. Elliott,
E. M. Bond,
B. Dodson,
G. Rusev,
R. Massarczyk,
S. J. Meijer,
M. Stortini,
C. Wiseman
Abstract:
We detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8$\times10^6$~dpm) \nuc{99}{Tc} $β$ source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of…
▽ More
We detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8$\times10^6$~dpm) \nuc{99}{Tc} $β$ source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation im**ing upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as \textsc{Majorana} and LEGEND.
△ Less
Submitted 10 November, 2022;
originally announced November 2022.
-
Calibration sources for the LEGEND-200 experiment
Authors:
L. Baudis,
G. Benato,
E. M. Bond,
P. -J. Chiu,
S. R. Elliott,
R. Massarczyk,
S. Meijer,
Y. Müller
Abstract:
In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the $Q$-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in $^{76}$Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resol…
▽ More
In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the $Q$-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in $^{76}$Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission $^{228}$Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma-activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of $\left( 4.27 \pm 0.60_{\rm stat} \pm 0.92_{\rm syst} \right) \times 10^{-4} ~\text{n / (kBq$\cdot$s)}$, approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of $^{76}$Ge, is negligible compared to other background sources in LEGEND-200.
△ Less
Submitted 1 February, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Development of holmium-163 electron-capture spectroscopy with transition-edge sensors
Authors:
M. P. Croce,
M. W. Rabin,
V. Mocko,
G. J. Kunde,
E. R. Birnbaum,
E. M. Bond,
J. W. Engle,
A. S. Hoover,
F. M. Nortier,
A. D. Pollington,
W. A. Taylor,
N. R. Weisse-Bernstein,
L. E. Wolfsberg,
J. P. Hays-Wehle,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
T. E. Barnhart,
R. J. Nickles
Abstract:
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short half-life (4570 y) of 163Ho make it attractive for high-precision electron capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum go…
▽ More
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short half-life (4570 y) of 163Ho make it attractive for high-precision electron capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the esca** neutrino. We have developed a complete process for proton-irradiation-based isotope production, isolation, and purification of 163Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163Ho. We present our work in these areas and discuss the measured spectrum and its comparison to current theory.
△ Less
Submitted 20 October, 2015; v1 submitted 13 October, 2015;
originally announced October 2015.