The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental propert…
▽ More
The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, $-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}}$ = $1.000\,000\,000\,003 (16)$, is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of $1.96\cdot10^{-27}\,$GeV (C$.$L$.$ 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP$_\text{cc}$) for antimatter to a level of $|α_{g}-1| < 1.8 \cdot 10^{-7}$, and enables the first differential test of the WEP$_\text{cc}$ using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP$_\text{cc}$-violating coefficient to $|α_{g,D}-1|<0.030$.
△ Less
Submitted 27 November, 2023;
originally announced November 2023.
-
KinFit -- A Kinematic Fitting Package for Hadron Physics Experiments
Authors:
Waleed Esmail,
Jana Rieger,
Jenny Taylor,
Malin Bohman,
Karin Schönning
Abstract:
A kinematic fitting package, KinFit, based on the Lagrange multiplier technique has been implemented for generic hadron physics experiments. It is particularly suitable for experiments where the interaction point is unknown, such as experiments with extended target volumes. The KinFit package includes vertex finding tools and fitting with kinematic constraints, such as mass hypothesis and four-mom…
▽ More
A kinematic fitting package, KinFit, based on the Lagrange multiplier technique has been implemented for generic hadron physics experiments. It is particularly suitable for experiments where the interaction point is unknown, such as experiments with extended target volumes. The KinFit package includes vertex finding tools and fitting with kinematic constraints, such as mass hypothesis and four-momentum conservation, as well as combinations of these constraints. The new package is distributed as an open source software via GitHub.
This paper presents a comprehensive description of the KinFit package and its features, as well as a benchmark study using Monte Carlo simulations of the $pp\rightarrow pK^+Λ\rightarrow pK^+pπ^-$ reaction. The results show that KinFit improves the parameter resolution and provides an excellent basis for event selection.
△ Less
Submitted 5 September, 2023; v1 submitted 18 August, 2023;
originally announced August 2023.
-
Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap
Authors:
Markus Wiesinger,
Florian Stuhlmann,
Matthew A. Bohman,
Peter Micke,
Christian Will,
Hüseyin Yildiz,
Fatma Abbass,
Bela P. Arndt,
Jack A. Devlin,
Stefan Erlewein,
Markus Fleck,
Julia I. Jäger,
Barbara M. Latacz,
Daniel Schweitzer,
Gilbertas Umbrazunas,
Elise Wursten,
Klaus Blaum,
Yasuyuki Matsuda,
Andreas Mooser,
Wolfgang Quint,
Anna Soter,
Jochen Walz,
Christian Smorra,
Stefan Ulmer
Abstract:
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at ro…
▽ More
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Enhancing Divalent Optical Atomic Clocks with the $^{1}\mathrm{S}_0$$\leftrightarrow$$^{3}\mathrm{P}_{2}$ Transition
Authors:
Matthew A. Bohman,
Sergey G. Porsev,
David B. Hume,
David R. Leibrandt,
Marianna S. Safronova
Abstract:
Divalent atoms and ions with a singlet $S$ ground state and triplet $P$ excited state form the basis of many high-precision optical atomic clocks. Along with the metastable $^{3}\mathrm{P}_{0}$ clock state, these atomic systems also have a nearby metastable $^{3}\mathrm{P}_{2}$ state. We investigate the properties of the electric quadrupole $^{1}\mathrm{S}_0$$\leftrightarrow$$^{3}\mathrm{P}_{2}$ t…
▽ More
Divalent atoms and ions with a singlet $S$ ground state and triplet $P$ excited state form the basis of many high-precision optical atomic clocks. Along with the metastable $^{3}\mathrm{P}_{0}$ clock state, these atomic systems also have a nearby metastable $^{3}\mathrm{P}_{2}$ state. We investigate the properties of the electric quadrupole $^{1}\mathrm{S}_0$$\leftrightarrow$$^{3}\mathrm{P}_{2}$ transition with a focus on enhancing already existing optical atomic clocks. In particular, we investigate the $^{1}\mathrm{S}_0$$\leftrightarrow$$^{3}\mathrm{P}_{2}$ transition in $^{27}\mathrm{Al}^{+}$ and calculate the differential polarizability, hyperfine effects, and other relevant atomic properties. We also discuss potential applications of this transition, notably that it provides two transitions with different sensitivities to systematic effects in the same species. In addition, we describe how the $^{1}\mathrm{S}_0$$\leftrightarrow$$^{3}\mathrm{P}_{2}$ transition can be used to search for physics beyond the Standard Model and motivate investigation of this transition in other existing optical atomic clocks.
△ Less
Submitted 3 August, 2023;
originally announced August 2023.
-
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Authors:
C. Smorra,
F. Abbass,
M. Bohman,
Y. Dutheil,
A. Hobl,
D. Popper,
B. Arndt,
B. B. Bauer,
J. A. Devlin,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
P. Micke,
M. Schiffelholz,
G. Umbrazunas,
M. Wiesinger,
C. Will,
E. Wursten,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
W. Quint
, et al. (4 additional authors not shown)
Abstract:
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To…
▽ More
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pum** section to suppress the residual gas flow into the cryogenic trap chamber.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Sympathetic cooling schemes for separately trapped ions coupled via image currents
Authors:
C. Will,
M. Bohman,
T. Driscoll,
M. Wiesinger,
F. Abbass,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
M. Fleck,
B. Latacz,
R. Moller,
A. Mooser,
D. Popper,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and fin…
▽ More
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Sympathetic cooling of a trapped proton mediated by an LC circuit
Authors:
M. Bohman,
V. Grunhofer,
C. Smorra,
M. Wiesinger,
C. Will,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
M. Fleck,
S. Gavranovic,
J. Harrington,
B. Latacz,
A. Mooser,
D. Popper,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
S. Ulmer
Abstract:
Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to prev…
▽ More
Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be+ ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image-current interactions, it can be easily applied to an experiment with antiprotons, facilitating improved precision in matter-antimatter comparisons and dark matter searches.
△ Less
Submitted 28 August, 2021;
originally announced August 2021.
-
Constraints on the Coupling between Axionlike Dark Matter and Photons Using an Antiproton Superconducting Tuned Detection Circuit in a Cryogenic Penning Trap
Authors:
Jack A. Devlin,
Matthias J. Borchert,
Stefan Erlewein,
Markus Fleck,
James A. Harrington,
Barbara Latacz,
Jan Warncke,
Elise Wursten,
Matthew A. Bohman,
Andreas H. Mooser,
Christian Smorra,
Markus Wiesinger,
Christian Will,
Klaus Blaum,
Yasuyuki Matsuda,
Christian Ospelkaus,
Wolfgang Quint,
Jochen Walz,
Yasunori Yamazaki,
Stefan Ulmer
Abstract:
We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs…
▽ More
We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs with masses around $2.7906-2.7914\,\textrm{neV/c}^2$ to $g_{aγ}< 1 \times 10^{-11}\,\textrm{GeV}^{-1}$. This is more than one order of magnitude lower than the best laboratory haloscope and approximately 5 times lower than the CERN axion solar telescope (CAST), setting limits in a mass and coupling range which is not constrained by astrophysical observations. Our approach can be extended to many other Penning-trap experiments and has the potential to provide broad limits in the low ALP mass range.
△ Less
Submitted 27 January, 2021;
originally announced January 2021.
-
Direct limits on the interaction of antiprotons with axion-like dark matter
Authors:
C. Smorra,
Y. V. Stadnik,
P. E. Blessing,
M. Bohman,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
J. A. Harrington,
T. Higuchi,
A. Mooser,
G. Schneider,
M. Wiesinger,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
D. Budker,
S. Ulmer
Abstract:
Astrophysical observations indicate that there is roughly five times more dark matter in the Universe than ordinary baryonic matter, with an even larger amount of the Universe's energy content due to dark energy. So far, the microscopic properties of these dark components have remained shrouded in mystery. In addition, even the five percent of ordinary matter in our Universe has yet to be understo…
▽ More
Astrophysical observations indicate that there is roughly five times more dark matter in the Universe than ordinary baryonic matter, with an even larger amount of the Universe's energy content due to dark energy. So far, the microscopic properties of these dark components have remained shrouded in mystery. In addition, even the five percent of ordinary matter in our Universe has yet to be understood, since the Standard Model of particle physics lacks any consistent explanation for the predominance of matter over antimatter. Inspired by these central problems of modern physics, we present here a direct search for interactions of antimatter with dark matter, and place direct constraints on the interaction of ultra-light axion-like particles $-$ one of the dark-matter candidates $-$ and antiprotons. If antiprotons exhibit a stronger coupling to these dark-matter particles than protons, such a CPT-odd coupling could provide a link between dark matter and the baryon asymmetry in the Universe. We analyse spin-flip resonance data acquired with a single antiproton in a Penning trap [Smorra et al., Nature 550, 371 (2017)] in the frequency domain to search for spin-precession effects from ultra-light axions with a characteristic frequency governed by the mass of the underlying particle. Our analysis constrains the axion-antiproton interaction parameter $f_a/C_{\overline{p}}$ to values greater than $0.1$ to $0.6$ GeV in the mass range from $2 \times 10^{-23}$ to $4 \times 10^{-17}\,$eV/$c^2$, improving over astrophysical antiproton bounds by up to five orders of magnitude. In addition, we derive limits on six combinations of previously unconstrained Lorentz-violating and CPT-violating terms of the non-minimal Standard Model Extension.
△ Less
Submitted 30 May, 2020;
originally announced June 2020.
-
Measurement of ultra-low heating rates of a single antiproton in a cryogenic Penning trap
Authors:
M. J. Borchert,
P. E. Blessing,
J. A. Devlin,
J. A. Harrington,
T. Higuchi,
J. Morgner,
C. Smorra,
E. Wursten,
M. Bohman,
M. Wiesinger,
A. Mooser,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron quantum transition rates of 6(1) quanta/h and an electric field noise spectral density below $7.5(3.4)\times 10^{-20}\,\text{V}^{2}\text{m}^{-2} \text{Hz}^{-1}$, which corresponds to a scaled noise spectral density below…
▽ More
We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron quantum transition rates of 6(1) quanta/h and an electric field noise spectral density below $7.5(3.4)\times 10^{-20}\,\text{V}^{2}\text{m}^{-2} \text{Hz}^{-1}$, which corresponds to a scaled noise spectral density below $8.8(4.0)\times 10^{-12}\,\text{V}^{2}\text{m}^{-2}$, results which are more than two orders of magnitude smaller than those reported by other ion trap experiments.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Sympathetic Cooling of Protons and Antiprotons with a Common Endcap Penning Trap
Authors:
M. Bohman,
A. Mooser,
G. Schneider,
N Schön,
M. Wiesinger,
J. Harrington,
T. Higuchi,
H. Nagahama,
S. Sellner,
C. Smorra,
K. Blaum,
Y. Matsuda,
W. Quint,
J. Walz,
S. Ulmer
Abstract:
We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap technique. Our analysis shows that preparation of (anti)protons at mK temperatures on timescales of tens of seconds is feasible. Successful implementation of the technique will have immediate and significant impact on h…
▽ More
We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap technique. Our analysis shows that preparation of (anti)protons at mK temperatures on timescales of tens of seconds is feasible. Successful implementation of the technique will have immediate and significant impact on high-precision comparisons of the fundamental properties of protons and antiprotons. This in turn will provide some of the most stringent tests of the fundamental symmetries of the Standard Model.
△ Less
Submitted 1 September, 2017;
originally announced September 2017.
-
Observation of individual spin quantum transitions of a single antiproton
Authors:
C. Smorra,
A. Mooser,
M. Besirli,
M. Bohman,
M. J. Borchert,
J. Harrington,
T. Higuchi,
H. Nagahama,
G. L. Schneider,
S. Sellner,
T. Tanaka,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We report on the detection of individual spin quantum transitions of a single trapped antiproton in a Penning trap. The spin-state determination, which is based on the unambiguous detection of axial frequency shifts in presence of a strong magnetic bottle, reaches a fidelity of 92.1$\%$. Spin-state initialization with $>99.9\%$ fidelity and an average initialization time of 24 min are demonstrated…
▽ More
We report on the detection of individual spin quantum transitions of a single trapped antiproton in a Penning trap. The spin-state determination, which is based on the unambiguous detection of axial frequency shifts in presence of a strong magnetic bottle, reaches a fidelity of 92.1$\%$. Spin-state initialization with $>99.9\%$ fidelity and an average initialization time of 24 min are demonstrated. This is a major step towards an antiproton magnetic moment measurement with a relative uncertainty on the part-per-billion level.
△ Less
Submitted 21 March, 2017;
originally announced March 2017.