Demonstration of High-Efficiency Microwave Heating Producing Record Highly Charged Xenon Ion Beams with Superconducting ECR Ion Sources
Authors:
X. Wang,
J. B. Li,
V. Mironov,
J. W. Guo,
X. Z. Zhang,
O. Tarvainen,
Y. C. Feng,
L. X. Li,
J. D. Ma,
Z. H. Zhang,
W. Lu,
S. Bogomolov,
L. Sun,
H. W. Zhao
Abstract:
Intense highly charged ion beam production is essential for high-power heavy ion accelerators. A novel movable Vlasov launcher for superconducting high charge state Electron Cyclotron Resonance (ECR) ion source has been devised that can affect the microwave power effectiveness by a factor of about 4 in terms of highly charged ion beam production. This approach based on a dedicated microwave launch…
▽ More
Intense highly charged ion beam production is essential for high-power heavy ion accelerators. A novel movable Vlasov launcher for superconducting high charge state Electron Cyclotron Resonance (ECR) ion source has been devised that can affect the microwave power effectiveness by a factor of about 4 in terms of highly charged ion beam production. This approach based on a dedicated microwave launching system instead of the traditional coupling scheme has led to new insight on microwave-plasma interaction. With this new understanding, the world record highly charged xenon ion beam currents have been enhanced by up to a factor of 2, which could directly and significantly enhance the performance of heavy ion accelerators and provide many new research opportunities in nuclear physics, atomic physics and other disciplines.
△ Less
Submitted 25 June, 2024; v1 submitted 19 June, 2024;
originally announced June 2024.
-
Development and validation of the numerical model of Electron Cyclotron Resonance Ion Sources
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov,
D. Pugachev
Abstract:
Processes of the secondary electron emission (SEE) from the walls are included into the Numerical Advanced Model of Electron Cyclotron Resonance Ion Sources (NAM-ECRIS). It is found that SEE strongly influences electron confinement time and ion production. With the modified model, we observe reactions of the source to changes in a gas flow into the source and in an injected microwave power. The so…
▽ More
Processes of the secondary electron emission (SEE) from the walls are included into the Numerical Advanced Model of Electron Cyclotron Resonance Ion Sources (NAM-ECRIS). It is found that SEE strongly influences electron confinement time and ion production. With the modified model, we observe reactions of the source to changes in a gas flow into the source and in an injected microwave power. The source performance with scaling the hexapole magnetic field is investigated. The calculated tendencies are close to the experimental observations.
△ Less
Submitted 26 April, 2022;
originally announced April 2022.
-
Numerical investigations of the minimum-B effect in Electron Cyclotron Resonance Ion Source
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov,
D. Pugachev
Abstract:
The three-dimensional particle-in-cell model NAM-ECRIS is used for investigation of how the DECRIS-PM Electron Cyclotron Resonance Ion Source is reacting to changes in the source magnetic configuration. The accent is made on changes in the magnetic field at the magnetic trap center, the minimum-B value. It is calculated that the optimal normalized value of the field is ~0.8, close to the experimen…
▽ More
The three-dimensional particle-in-cell model NAM-ECRIS is used for investigation of how the DECRIS-PM Electron Cyclotron Resonance Ion Source is reacting to changes in the source magnetic configuration. The accent is made on changes in the magnetic field at the magnetic trap center, the minimum-B value. It is calculated that the optimal normalized value of the field is ~0.8, close to the experimental observations. The reasons for existence of the optimum are discussed. It is observed that the electron energies are increasing with the increased minimum-B values due to enhanced confinement of the energetic electrons in the plasma. Bumps in energy spectra of the radially lost electrons are observed and explained to be due to nonadiabatic losses of electrons.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
On optimization of the metal ion production by Electron Cyclotron Resonance Ion Sources
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
K. Kuzmenkov,
V. Loginov,
D. Pugachev
Abstract:
The three-dimensional NAM-ECRIS model is applied for studying the metal ion production in the DECRIS-PM Electron Cyclotron Resonance Ion Source. Experimentally measured extracted ion currents are accurately reproduced with the model. Parameters of the injection of metal vapors into the source are optimized. It is found that the axial injection of the highly directional fluxes allows increasing the…
▽ More
The three-dimensional NAM-ECRIS model is applied for studying the metal ion production in the DECRIS-PM Electron Cyclotron Resonance Ion Source. Experimentally measured extracted ion currents are accurately reproduced with the model. Parameters of the injection of metal vapors into the source are optimized. It is found that the axial injection of the highly directional fluxes allows increasing the extracted ion currents of the highly charged calcium ions by factor of 1.5. The reason for the gain in the currents is formation of internal barrier for the ions inside the plasma, which increase the ion extraction and production efficiency. Benefits of injecting the singly-charged calcium ions instead of atoms are discussed.
△ Less
Submitted 8 October, 2020;
originally announced October 2020.
-
Three-dimensional modelling of processes in Electron Cyclotron Resonance Ion Source
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov,
D. Pugachev
Abstract:
Three-dimensional numerical model is developed and applied for studies of physical processes in Electron Cyclotron Resonance Ion Source. The model includes separate modules that simulate the electron and ion dynamics in the source plasma in an iterative way. The electron heating by microwaves is simulated by using results of modelling the microwave propagation in the plasma by the COMSOL Multiphys…
▽ More
Three-dimensional numerical model is developed and applied for studies of physical processes in Electron Cyclotron Resonance Ion Source. The model includes separate modules that simulate the electron and ion dynamics in the source plasma in an iterative way. The electron heating by microwaves is simulated by using results of modelling the microwave propagation in the plasma by the COMSOL Multiphysics software. Extracted ion currents and other parameters of the source are obtained for different gas flows into the source. It is observed that the currents are strongly influenced by ion transport in transversal direction induced by the plasma potential gradients. Impact of some special techniques on the source performance is investigated. Magnetic field scaling is shown to reduce the ion losses during their movement toward the extraction aperture, as well as use of the aluminum chamber walls and mixing of the working gas with helium.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
Spatial distributions of plasma potential and density in electron cyclotron resonance ion source
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov,
D. Pugachev
Abstract:
The Numerical Advanced Model of Electron Cyclotron Resonance Ion Source (NAM-ECRIS) is applied for studies of the physical processes in the source. Solutions of separately operating electron and ion modules of NAM-ECRIS are matched in iterative way such as to obtain the spatial distributions of the plasma density and of the plasma potential. Results reveal the complicated profiles with the maximiz…
▽ More
The Numerical Advanced Model of Electron Cyclotron Resonance Ion Source (NAM-ECRIS) is applied for studies of the physical processes in the source. Solutions of separately operating electron and ion modules of NAM-ECRIS are matched in iterative way such as to obtain the spatial distributions of the plasma density and of the plasma potential. Results reveal the complicated profiles with the maximized plasma density close to the ECR surface and on the source axis. The ion-trap** potential dips are calculated to be on the level of ~(0.01-0.05) V being located at the plasma density maxima. The highly charged ions are also localized close to the ECR surface. The biased electrode effect is due to an electron string along the source axis formed by reflection of electrons from the biased electrode and the extraction aperture. The string makes profiles of the highly charged ions more peaked on the source axis, thus increasing the extracted ion currents.
△ Less
Submitted 8 September, 2019;
originally announced September 2019.
-
Simulations of charge-breeding processes in ECRIS
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov
Abstract:
Charge-breeding processes in Electron Cyclotron Resonance Ion Sources are numerically simulated by using the target helium plasma parameters obtained with NAM-ECRIS code. Breeding efficiency is obtained as a function of 1+ ion injection energy for some alkali ion beams. Time dependencies of extracted ions are calculated; typical times for reaching saturation in currents are in the range of few ten…
▽ More
Charge-breeding processes in Electron Cyclotron Resonance Ion Sources are numerically simulated by using the target helium plasma parameters obtained with NAM-ECRIS code. Breeding efficiency is obtained as a function of 1+ ion injection energy for some alkali ion beams. Time dependencies of extracted ions are calculated; typical times for reaching saturation in currents are in the range of few tens of milliseconds. Role of charge-exchange processes in breeding of ions is discussed. Recycling of ions on the source walls is shown to be important.
△ Less
Submitted 23 June, 2017;
originally announced June 2017.
-
On Optical Properties Of Ion Beams Extracted From Electron Cyclotron Resonance Ion Source
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov
Abstract:
Ion extraction from DECRIS-PM source is simulated by using initial distributions of ions at the extraction aperture obtained with NAM-ECRIS code. Three-dimensional calculations of plasma emissive surface are done and ions are traced in the extraction region. The ion beam profiles show strong aberrations due to shape of plasma meniscus; hollow beam features are reproduced, as well as changes in pro…
▽ More
Ion extraction from DECRIS-PM source is simulated by using initial distributions of ions at the extraction aperture obtained with NAM-ECRIS code. Three-dimensional calculations of plasma emissive surface are done and ions are traced in the extraction region. The ion beam profiles show strong aberrations due to shape of plasma meniscus; hollow beam features are reproduced, as well as changes in profiles for different focusing conditions.
△ Less
Submitted 23 June, 2017;
originally announced June 2017.
-
Some Aspects of Electron Dynamics in Electron Cyclotron Resonance Ion Sources
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov
Abstract:
Electron dynamics in Electron Cyclotron Resonance Ion Source is numerically simulated by using Particle-In-Cell code combined with simulations of the ion dynamics. Mean electron energies are found to be around 70 keV close to values that are derived from spectra of X-ray emission out of the source. Electron life time is defined by losses of low-energy electrons created in ionizing collisions; the…
▽ More
Electron dynamics in Electron Cyclotron Resonance Ion Source is numerically simulated by using Particle-In-Cell code combined with simulations of the ion dynamics. Mean electron energies are found to be around 70 keV close to values that are derived from spectra of X-ray emission out of the source. Electron life time is defined by losses of low-energy electrons created in ionizing collisions; the losses are regulated by electron heating rate, which depends on magnitude of the microwave electric field. Changes in ion confinement with variations in the microwave electric field and gas flow are simulated. Influence of electron dynamics on the afterglow and two-frequency heating effects is discussed.
△ Less
Submitted 1 February, 2017;
originally announced February 2017.
-
Numerical simulations of gas mixing effect in Electron Cyclotron Resonance Ion Sources
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov
Abstract:
The particle-in-cell MCC code NAM-ECRIS is used to simulate the ECRIS plasma sustained in a mixture of Kr with O2, N2, Ar, Ne and He. The model assumes that ions are electrostatically confined in ECR zone by a dip in the plasma potential. Gain in the extracted krypton ion currents is seen for the highest charge states; the gain is maximized when oxygen is used as the mixing gas. A special feature…
▽ More
The particle-in-cell MCC code NAM-ECRIS is used to simulate the ECRIS plasma sustained in a mixture of Kr with O2, N2, Ar, Ne and He. The model assumes that ions are electrostatically confined in ECR zone by a dip in the plasma potential. Gain in the extracted krypton ion currents is seen for the highest charge states; the gain is maximized when oxygen is used as the mixing gas. A special feature of oxygen is that most of singly charged oxygen ions are produced after dissociative ionization of oxygen molecules with the large kinetic energy release of around 5 eV per ion. Increased loss rate of energetic lowly charged ions of the mixing element requires building up of the retarding potential barrier close to ECR surface to equilibrate electron and ion losses out of the plasma. In the mixed plasmas, the barrier value is large (~1 V) compared to the pure Kr plasma (~0.01 V), with the longer confinement times of krypton ions and with the much higher ion temperatures.
△ Less
Submitted 25 July, 2016;
originally announced July 2016.
-
Numerical model of Electron Cyclotron Resonance Ion Source
Authors:
V. Mironov,
S. Bogomolov,
A. Bondarchenko,
A. Efremov,
V. Loginov
Abstract:
Important features of Electron Cyclotron Resonance Ion Source (ECRIS) operation are accurately reproduced with a numerical code. The code uses the particle-in-cell technique to model a dynamics of ions in ECRIS plasma. It is shown that gas dynamical ion confinement mechanism is sufficient to provide the ion production rates in ECRIS close to the experimentally observed values. Extracted ion curren…
▽ More
Important features of Electron Cyclotron Resonance Ion Source (ECRIS) operation are accurately reproduced with a numerical code. The code uses the particle-in-cell technique to model a dynamics of ions in ECRIS plasma. It is shown that gas dynamical ion confinement mechanism is sufficient to provide the ion production rates in ECRIS close to the experimentally observed values. Extracted ion currents are calculated and compared to the experiment for few sources. Changes in the extracted ion currents are obtained with varying the gas flow into the source chamber and the microwave power. Empirical scaling laws for ECRIS design are studied and the underlying physical effects are discussed.
△ Less
Submitted 13 July, 2015;
originally announced July 2015.
-
Predissociation dynamics of lithium iodide
Authors:
H. Schmidt,
J. von Vangerow,
F. Stienkemeier,
A. S. Bogomolov,
A. V. Baklanov,
D. M. Reich,
W. Skomorowski,
C. P. Koch,
M. Mudrich
Abstract:
The predissociation dynamics of lithium iodide (LiI) in the first excited A-state is investigated for molecules in the gas phase and embedded in helium nanodroplets, using femtosecond pump-probe photoionization spectroscopy. In the gas phase, the transient Li+ and LiI+ ion signals feature damped oscillations due to the excitation and decay of a vibrational wave packet. Based on high-level ab initi…
▽ More
The predissociation dynamics of lithium iodide (LiI) in the first excited A-state is investigated for molecules in the gas phase and embedded in helium nanodroplets, using femtosecond pump-probe photoionization spectroscopy. In the gas phase, the transient Li+ and LiI+ ion signals feature damped oscillations due to the excitation and decay of a vibrational wave packet. Based on high-level ab initio calculations of the electronic structure of LiI and simulations of the wave packet dynamics, the exponential signal decay is found to result from predissociation predominantly at the lowest avoided X-A potential curve crossing, for which we infer a coupling constant V=650(20) reciprocal cm. The lack of a pump-probe delay dependence for the case of LiI embedded in helium nanodroplets indicates fast droplet-induced relaxation of the vibrational excitation.
△ Less
Submitted 14 January, 2015;
originally announced January 2015.