SND electromagnetic calorimeter time measurement and its applications
Authors:
M. N. Achasov,
A. G. Bogdanchikov,
V. P. Druzhinin,
A. A. Korol,
D. P. Kovrizhin,
N. A. Melnikova,
S. I. Serednyakov,
I. K. Surin,
A. I. Tekut'ev,
Yu. V. Usov,
V. V. Zhulanov
Abstract:
The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measureme…
▽ More
The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measurement in counters was possible. A new EMC signal sha** and digitizing electronics based on FADC allows us to obtain also the event time structure. The new electronics and supporting software, including digital signal processing algorithms, are used for data taking in the ongoing experiment. We discuss the amplitude and time extraction algorithms, the new system performance on experimental events and physical analysis applications.
△ Less
Submitted 2 June, 2020; v1 submitted 14 May, 2020;
originally announced May 2020.
-
SND data acquisition system upgrade
Authors:
A. G. Bogdanchikov,
V. P. Druzhinin,
A. A. Korol,
S. V. Koshuba,
A. I. Tekutiev,
Yu. V. Usov
Abstract:
The data acquisition (DAQ) system of the SND detector successfully operated during four data-taking seasons (2010-2013) at the e+e- collider VEPP-2000. Currently the collider is shut down for planned reconstruction, which is expected to increase the VEPP-2000 luminosity and data flow from the SND detector electronics by up to 10 times.
Since current DAQ system implementation (electronics and comp…
▽ More
The data acquisition (DAQ) system of the SND detector successfully operated during four data-taking seasons (2010-2013) at the e+e- collider VEPP-2000. Currently the collider is shut down for planned reconstruction, which is expected to increase the VEPP-2000 luminosity and data flow from the SND detector electronics by up to 10 times.
Since current DAQ system implementation (electronics and computer part) does not have enough reserve for selection of events in the new environment without compromising quality, there arose the need for the system upgrade.
Here we report on the major SND data acquisition system upgrade which includes develo** new electronics for digitization and data transfer, complete redesign of the data network, increasing of the DAQ computer farm processing capacity and making the event building process concurrent. These measures will allow us to collect data flow from the most congested detector subsystems in parallel in contrast to the current situation. We would like to discuss also the possibility to implement full software trigger solution in the future.
△ Less
Submitted 2 April, 2014;
originally announced April 2014.
-
Spherical Neutral Detector for VEPP-2M collider
Authors:
M. N. Achasov,
V. M. Aulchenko,
S. E. Baru,
K. I. Beloborodov,
A. V. Berdyugin,
A. G. Bogdanchikov,
A. V. Bozhenok,
A. D. Bukin,
D. A. Bukin,
S. V. Burdin,
T. V. Dimova,
S. I. Dolinsky,
A. A. Drozdetsky,
V. P. Druzhinin,
M. S. Dubrovin,
I. A. Gaponenko,
V. B. Golubev,
V. N. Ivanchenko,
A. A. Korol,
S. V. Koshuba,
G. A. Kukartsev,
E. V. Pakhtusova,
V. M. Popov,
A. A. Salnikov,
S. I. Serednyakov
, et al. (7 additional authors not shown)
Abstract:
The Spherical Neutral Detector (SND) operates at VEPP-2M collider in Novosibirsk studying e^+e^- annihilation in the energy range up to 1.4 GeV. Detector consists of a fine granulated spherical scintillation calorimeter with 1632 NaI(Tl) crystals, two cylindrical drift chambers with 10 layers of sense wires, and a muon system made of streamer tubes and plastic scintillation counters. The detecto…
▽ More
The Spherical Neutral Detector (SND) operates at VEPP-2M collider in Novosibirsk studying e^+e^- annihilation in the energy range up to 1.4 GeV. Detector consists of a fine granulated spherical scintillation calorimeter with 1632 NaI(Tl) crystals, two cylindrical drift chambers with 10 layers of sense wires, and a muon system made of streamer tubes and plastic scintillation counters. The detector design, performance, data acquisition and processing are described.
△ Less
Submitted 10 September, 1999;
originally announced September 1999.