-
Use of Bayesian Optimization to Understand the Structure of Nuclei
Authors:
J. Hooker,
J. Kovoor,
K. L. Jones,
R. Kanungo,
M. Alcorta,
J. Allen,
C. Andreoiu,
L. Atar,
D. W. Bardayan,
S. S. Bhattacharjee,
D. Blankstein,
C. Burbadge,
S. Burcher,
W. N. Catford,
S. Cha,
K. Chae,
D. Connolly,
B. Davids,
N. Esker,
F. H. Garcia,
S. Gillespie,
R. Ghimire,
A. Gula,
G. Hackman,
S. Hallam
, et al. (19 additional authors not shown)
Abstract:
Monte Carlo simulations are widely used in nuclear physics to model experimental systems. In cases where there are significant unknown quantities, such as energies of states, an iterative process of simulating and fitting is often required to describe experimental data. We describe a Bayesian approach to fitting experimental data, designed for data from a $^{12}$Be(d,p) reaction measurement, using…
▽ More
Monte Carlo simulations are widely used in nuclear physics to model experimental systems. In cases where there are significant unknown quantities, such as energies of states, an iterative process of simulating and fitting is often required to describe experimental data. We describe a Bayesian approach to fitting experimental data, designed for data from a $^{12}$Be(d,p) reaction measurement, using simulations made with GEANT4. Q-values from the $^{12}$C(d,p) reaction to well-known states in $^{13}$C are compared with simulations using BayesOpt. The energies of the states were not included in the simulation to reproduce the situation for $^{13}$Be where the states are poorly known. Both cases had low statistics and significant resolution broadening owing to large proton energy losses in the solid deuterium target. Excitation energies of the lowest three excited states in $^{13}$C were extracted to better than 90 keV, paving a way for extracting information on $^{13}$Be.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
MuSIC@Indiana: an effective tool for accurate measurement of fusion with low-intensity radioactive beams
Authors:
J. E. Johnstone,
Rohit Kumar,
S. Hudan,
Varinderjit Singh,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. M. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley
Abstract:
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. Mu…
▽ More
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. MuSIC@Indiana was commissioned by measuring the $^{18}$O+$^{12}$C fusion excitation function for 11 $<$ E$_{cm}$ $<$ 20 MeV using CH$_{4}$ gas. A simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
The Notre-Dame Cube: An active-target time-projection chamber for radioactive beam experiments and detector development
Authors:
T. Ahn,
J. S. Randhawa,
S. Aguilar,
D. Blankstein,
L. Delgado,
N. Dixneuf,
S. L. Henderson,
W. Jackson,
L. Jensen,
S. **,
J. Koci,
J. J. Kolata,
J. Lai,
J. Levano,
X. Li,
A. Mubarak,
P. D. O'Malley,
S. Rameriz Martin,
M. Renaud,
M. Z. Serikow,
A. Tollefson,
J. Wilson,
L. Yan
Abstract:
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characte…
▽ More
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characterized. The ND-Cube was commissioned with a $^{7}$Li beam for measuring $^{40}$Ar + $^{7}$Li fusion reaction cross sections and investigating $^{7}$Li($α$,$α$)$^{7}$Li scattering events. The ND-Cube will be used to study a range of reactions using light radioactive ions produced at low energy.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.